PURPOSE: This study examined the feasibility of using quantitation to augment interpretation of florbetapir PET amyloid imaging. METHODS: A total of 80 physician readers were trained on quantitation of florbetapir PET images and the principles for using quantitation to augment a visual read. On day 1, the readers completed a visual read of 96 scans (46 autopsy-verified and 50 from patients seeking a diagnosis). On day 2, 69 of the readers reinterpreted the 96 scans augmenting their interpretation with quantitation (VisQ method) using one of three commercial software packages. A subset of 11 readers reinterpreted all scans on day 2 based on a visual read only (VisVis control). For the autopsy-verified scans, the neuropathologist's modified CERAD plaque score was used as the truth standard for interpretation accuracy. Because an autopsy truth standard was not available for scans from patients seeking a diagnosis, the majority VisQ interpretation of the three readers with the best accuracy in interpreting autopsy-verified scans was used as the reference standard. RESULTS: Day 1 visual read accuracy was high for both the autopsy-verified scans (90%) and the scans from patients seeking a diagnosis (87.3%). Accuracy improved from the visual read to the VisQ read (from 90.1% to 93.1%, p < 0.0001). Importantly, access to quantitative information did not decrease interpretation accuracy of the above-average readers (>90% on day 1). Accuracy in interpreting the autopsy-verified scans also increased from the first to the second visual read (VisVis group). However, agreement with the reference standard (best readers) for scans from patients seeking a diagnosis did not improve with a second visual read, and in this cohort the VisQ group was significantly improved relative to the VisVis group (change 5.4% vs. -1.1%, p < 0.0001). CONCLUSION: These results indicate that augmentation of visual interpretation of florbetapir PET amyloid images with quantitative information obtained using commercially available software packages did not reduce the accuracy of readers who were already performing with above average accuracy on the visual read and may improve the accuracy and confidence of some readers in clinically relevant cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hyman, B. T., Phelps, C. H., Beach, T. G., Bigio, E. H., Cairns, N. J., Carrillo, M. C., Dickson, D. W., Duyckaerts, C., Frosch, M. P., Masliah, E., et al. (2012) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2011.10.007 · Cited by 3,092 · cited 1×
“PET imaging ligands including Pittsburgh compound B ((11)C-PIB) [2], (18)F-florbetaben [3], (18)F-flutemetamol [4] and (18)F-florbetapir [5] have been developed for estimation of cortical beta amyloid (Aβ) neuritic plaque deposition, a hallmark pathology, and a required element for the evaluation of neuropathological…”
BackgroundVillemagne, V. L., Burnham, S., Bourgeat, P., Brown, B., Ellis, K. A., Salvado, O., Szoeke, C., Macaulay, S. L., Martins, R., Maruff, P., et al. (2013) · The Lancet Neurology · doi:10.1016/s1474-4422(13)70044-9 · Cited by 2,279
Clark, C. M., Pontecorvo, M. J., Beach, T. G., Bedell, B. J., Coleman, R. E., Doraiswamy, P. M., Fleisher, A. S., Reiman, E. M., Sabbagh, M. N., Sadowsky, C. H., et al. (2012) · The Lancet Neurology · doi:10.1016/s1474-4422(12)70142-4 · Cited by 855 · cited 9×
“In the case of (18)F-florbetapir, the use of an exploratory quantitative approach resulted in an accuracy of 97% in relation to autopsy [7].”
BackgroundMethodInfluentialSelf-citationWong, D. F., Rosenberg, P. B., Zhou, Y., Kumar, A., Raymont, V., Ravert, H. T., Dannals, R. F., Nandi, A., Brašić, J. R., Ye, W., et al. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069088 · Cited by 684 · cited 1×
“PET imaging ligands including Pittsburgh compound B ((11)C-PIB) [2], (18)F-florbetaben [3], (18)F-flutemetamol [4] and (18)F-florbetapir [5] have been developed for estimation of cortical beta amyloid (Aβ) neuritic plaque deposition, a hallmark pathology, and a required element for the evaluation of neuropathological…”
BackgroundSelf-citationFDG-PET improves accuracy in distinguishing frontotemporal dementia and Alzheimer's disease
Foster, N. L., Heidebrink, J. L., Clark, C. M., Jagust, W. J., Arnold, S. E., Barbas, N. R., DeCarli, C. S., Scott Turner, R., Koeppe, R. A., Higdon, R., et al. (2007) · Brain · doi:10.1093/brain/awm177 · Cited by 608
Florbetaben PET imaging to detect amyloid beta plaques in Alzheimer's disease: Phase 3 study
Sabri, O., Sabbagh, M. N., Seibyl, J., Barthel, H., Akatsu, H., Ouchi, Y., Senda, K., Murayama, S., Ishii, K., Takao, M., et al. (2015) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2015.02.004 · Cited by 602
Comparing positron emission tomography imaging and cerebrospinal fluid measurements of β‐amyloid
Landau, S. M., Lu, M., Joshi, A. D., Pontecorvo, M., Mintun, M. A., Trojanowski, J. Q., Shaw, L. M., Jagust, W. J., & Initiative, F. T. A. D. N. (2013) · Annals of Neurology · doi:10.1002/ana.23908 · Cited by 401
Self-citationCurtis, C., Gamez, J. E., Singh, U., Sadowsky, C. H., Villena, T., Sabbagh, M. N., Beach, T. G., Duara, R., Fleisher, A. S., Frey, K. A., et al. (2015) · JAMA Neurology · doi:10.1001/jamaneurol.2014.4144 · Cited by 332
Johnson, K. A., Minoshima, S., Bohnen, N. I., Donohoe, K. J., Foster, N. L., Herscovitch, P., Karlawish, J. H., Rowe, C. C., Carrillo, M. C., Hartley, D. M., et al. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.120618 · Cited by 329
Cited by
Association of Factors With Elevated Amyloid Burden in Clinically Normal Older Individuals
Sperling, R. A., Donohue, M. C., Raman, R., Sun, C.-K., Yaari, R., Holdridge, K., Siemers, E., Johnson, K. A., Aisen, P. S., & for the A4 Study Team (2020) · JAMA Neurology · doi:10.1001/jamaneurol.2020.0387 · Cited by 324
Pontecorvo, M. J., Devous, M. D., Kennedy, I., Navitsky, M., Lu, M., Galante, N., Salloway, S., Doraiswamy, P. M., Southekal, S., Arora, A. K., et al. (2019) · Brain · doi:10.1093/brain/awz090 · Cited by 249
Self-citationQuantification of amyloid PET for future clinical use: a state-of-the-art review
Pemberton, H. G., Collij, L. E., Heeman, F., Bollack, A., Shekari, M., Salvadó, G., Alves, I. L., Garcia, D. V., Battle, M., Buckley, C., et al. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05784-y · Cited by 226
“those with visual read accuracy of ≤ 90% [63]; and (iii) more difficult to interpret cases, such as patients with unclear diagnoses or weaker grey-white matter differentiation [57, 109, 164].”
BackgroundResultInfluentialFlortaucipir F 18 quantitation using parametric estimation of reference signal intensity.
Southekal, S., Devous, M. D., Kennedy, I., Navitsky, M., Lu, M., Joshi, A. D., Pontecorvo, M. J., & Mintun, M. A. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.200006 · Cited by 92
“Subjects also had screening-visit 18F-florbetapir scans that were interpreted as Abpositive (Ab1) or Ab2 based on visual reads augmented by quantitative information, as previously described (26).”
MethodSelf-citationBucci, M., Savitcheva, I., Farrar, G., Salvadó, G., Collij, L., Doré, V., Gispert, J. D., Gunn, R., Hanseeuw, B., Hansson, O., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05311-5 · Cited by 50
Metadata
- Authors
- Pontecorvo, M. J., Arora, A. K., Devine, M., Lu, M., Galante, N., Siderowf, A., Devadanam, C., Joshi, A. D., Heun, S. L., Teske, B. F., Truocchio, S. P., Krautkramer, M., Devous, M. D., & Mintun, M. A.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2017-01-07
- Volume
- 44
- Issue
- 5
- Pages
- 825-837
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2570267351
- Cited by
- 68
- References
- 9
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.