Cited by 124Neuroendocrine Tumor Research AdvancesPancreatic function and diabetesMedical Imaging Techniques and Applications

Comparison of glucagon-like peptide-1 receptor (GLP-1R) PET/CT, SPECT/CT and 3T MRI for the localisation of occult insulinomas: evaluation of diagnostic accuracy in a prospective crossover imaging study

Open access
Antwi, Kwadwo, Fani, Melpomeni, Heye, Tobias, Nicolas, Guillaume, Rottenburger, Christof, Kaul, Felix, Merkle, Elmar, Zech, Christoph J. +5 more·2018·European Journal of Nuclear Medicine and Molecular Imaging

Abstract

Purpose Benign insulinomas are the most prevalent cause of endogenous hyperinsulinaemic hypoglycaemia (EHH) in adults, and because of their small size are difficult to localise. The purpose of the study was to test the diagnostic accuracy and clinical impact of glucagon-like peptide-1 receptor (GLP-1R) PET/CT using 68 Ga-DOTA-exendin-4 in consecutive adult patients referred for localisation of insulinomas. The results were compared with 111 In-DOTA-exendin-4 SPECT/CT, study-MRI and previously performed external CT and/or MRI (prior external CT/MRI). Methods We prospectively enrolled patients with neuroglycopenic symptoms due to EHH. GLP-1R PET/CT, SPECT/CT and study-MRI were performed in a randomised, crossover order within 3-4 days. The reference standard was surgery with histology and treatment outcome. Results From January 2014 until March 2017, 52 patients were recruited. All imaging and invasive procedures before recruitment identified suspicious lesions in 46.2% of patients. GLP-1R PET/CT, SPECT/CT and study-MRI detected suspicious lesions in 78.8%, 63.5% and 63.4% of patients, respectively. In 38 patients, conclusive histology was available for final analysis. Accuracy (95% confidence interval) for PET/CT, SPECT/CT, study-MRI and prior external CT/MRI was 93.9% (87.8-97.5%), 67.5% (58.1-76.0%), 67.6% (58.0-76.1%) and 40.0% (23.9-57.9%), respectively (all P values Conclusion 68 Ga-DOTA-exendin-4 PET/CT performed significantly better than 111 In-DOTA-exendin-4 SPECT/CT a…

Integrity signals

Registry

Crossref · 10.1007/s00259-018-4101-5

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Antwi, K., Fani, M., Heye, T., Nicolas, G., Rottenburger, C., Kaul, F., Merkle, E., Zech, C. J., Boll, D., Vogt, D. R., Gloor, B., Christ, E., & Wild, D.
Affiliations
  • University Hospital of Basel (CH)
  • University of Basel (CH)
  • University Hospital of Bern (CH)
Corresponding author
Wild, Damian
Venue
European Journal of Nuclear Medicine and Molecular Imaging
Published
2018-07-28
Volume
45
Issue
13
Pages
2318-2327
ISSN
  • 1619-7070 (ISSN-L)
  • 1619-7089
OpenAlex
W2883162736
Cited by
124
References
1
Citations by year
2025: 19 · 2024: 15 · 2023: 17 · 2022: 19 · 2021: 22 · 2020: 14 · 2019: 18
FWCI
10.54
Type
journal article
Language
en
Open access
Locations
  • European Journal of Nuclear Medicine and Molecular Imaging (publishedVersion)
  • PubMed (publishedVersion)
  • Bern Open Repository and Information System (University of Bern) (submittedVersion, other-oa)
  • Open Access CRIS of the University of Bern
Funders
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (320030-152938)
  • Desirée og Niels Ydes Fond (389-12)
Topics
  • Health Sciences › Medicine › Epidemiology › Neuroendocrine Tumor Research Advances
  • Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
Keywords
magnetic resonance imaging, neuroglycopenia, diagnostic accuracy, occult insulinoma, radioligand imaging
MeSH terms
Glucagon-Like Peptide-1 Receptor, Positron Emission Tomography Computed Tomography, Single Photon Emission Computed Tomography Computed Tomography, Adult, Female, Humans, Insulinoma, Magnetic Resonance Imaging, Male, Middle Aged, Prospective Studies, Sensitivity and Specificity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review