The False‐Negative Rate of Sentinel Node Biopsy in Patients with Breast Cancer: A Meta‐Analysis
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Background: In sentinel node surgery for breast cancer, procedural accuracy is assessed by calculating the false‐negative rate. It is important to measure this since there are potential adverse outcomes from missing node metastases. We performed a meta‐analysis of published data to assess which method has achieved the lowest false‐negative rate. Methods: We found 3,588 articles concerning sentinel nodes and breast cancer published from 1993 through mid‐2011; 183 articles met our inclusion criteria. The studies described in these 183 articles included a total of 9,306 patients. We grouped the studies by injection material and injection location. The false‐negative rates were analyzed according to these groupings and also by the year in which the articles were published. Results: There was significant variation related to injection material. The use of blue dye alone was associated with the highest false‐negative rate. Inclusion of a radioactive tracer along with blue dye resulted in a significantly lower false‐negative rate. Although there were variations in the false‐negative rate according to injection location, none were significant. Conclusions: The use of blue dye should be accompanied by a radioactive tracer to achieve a significantly lower false‐negative rate. Location of injection did not have a significant impact on the false‐negative rate. Given the limitations of acquiring appropriate data, the false‐negative rate should not be used as a metric for training or quality control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Borenstein, M., Hedges, L. V., Higgins, J. P. T., & Rothstein, H. R. (2009) · doi:10.1002/9780470743386 · Cited by 14,225
Borenstein, M., Hedges, L. V., Higgins, J. P. T., & Rothstein, H. R. (2021) · doi:10.1002/9781119558378 · Cited by 9,799
Introduction to Statistical Analysis.
Latshaw, V. V., Dixon, W. J., & Massey, F. J. (1957) · The American Mathematical Monthly · doi:10.2307/2309989 · Cited by 5,072
A Randomized Comparison of Sentinel-Node Biopsy with Routine Axillary Dissection in Breast Cancer
Veronesi, U., Paganelli, G., Viale, G., Luini, A., Zurrida, S., Galimberti, V., Intra, M., Veronesi, P., Robertson, C., Maisonneuve, P., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa012782 · Cited by 2,210
The Sentinel Node in Breast Cancer — A Multicenter Validation Study
Krag, D., Weaver, D., Ashikaga, T., Moffat, F., Klimberg, V. S., Shriver, C., Feldman, S., Kusminsky, R., Gadd, M., Kuhn, J., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199810013391401 · Cited by 2,018
Self-citationKrag, D. N., Anderson, S. J., Julian, T. B., Brown, A. M., Harlow, S. P., Costantino, J. P., Ashikaga, T., Weaver, D. L., Mamounas, E. P., Jalovec, L. M., et al. (2010) · The Lancet Oncology · doi:10.1016/s1470-2045(10)70207-2 · Cited by 1,920 · cited 7×
“The FNR is measured by comparing the pathological status of the SNs to that of the remainder of the axillary nodes present in a completion axillary node resection (ANR).”
InfluentialSelf-citationSentinel lymphadenectomy in breast cancer.
Giuliano, A. E., Jones, R. C., Brennan, M., & Statman, R. (1997) · Journal of Clinical Oncology · doi:10.1200/jco.1997.15.6.2345 · Cited by 1,096
Krag, D. N., Anderson, S. J., Julian, T. B., Brown, A. M., Harlow, S. P., Ashikaga, T., Weaver, D. L., Miller, B. J., Jalovec, L. M., Frazier, T. G., et al. (2007) · The Lancet Oncology · doi:10.1016/s1470-2045(07)70278-4 · Cited by 1,060
Self-citationAn Introduction to Statistical Analysis.
Cochran, W. G., Dixon, W. J., & Massey, F. J. (1957) · Journal of the American Statistical Association · doi:10.2307/2280909 · Cited by 955
Lymphatic mapping and sentinel lymph node biopsy in early‐stage breast carcinoma: A metaanalysis
Kim, T., Giuliano, A. E., & Lyman, G. H. (2006) · Cancer · doi:10.1002/cncr.21568 · Cited by 840
Cited by
Deep learning radiomics can predict axillary lymph node status in early-stage breast cancer
Zheng, X., Yao, Z., Huang, Y., Yu, Y., Wang, Y., Liu, Y., Mao, R., Li, F., Xiao, Y., Wang, Y., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15027-z · Cited by 607
Giammarile, F., Alazraki, N., Aarsvold, J. N., Audisio, R. A., Glass, E., Grant, S. F., Kunikowska, J., Leidenius, M., Moncayo, V. M., Uren, R. F., et al. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2544-2 · Cited by 284
Diepstraten, S. C. E., Sever, A. R., Buckens, C. F. M., Veldhuis, W. B., van Dalen, T., van den Bosch, M. A. A. J., Mali, W. P. T. M., & Verkooijen, H. M. (2014) · Annals of Surgical Oncology · doi:10.1245/s10434-013-3229-6 · Cited by 187
“Nevertheless, the miss rate of SNB is reported to be as low as 7 %.(47)”
Background
Metadata
- Authors
- Pesek, S., Ashikaga, T., Krag, L. E., & Krag, D.
- Venue
- World Journal of Surgery
- Publisher
- Wiley
- Published
- 2012-05-09
- Volume
- 36
- Issue
- 9
- Pages
- 2239-2251
- ISSN
- 0364-2313 (ISSN-L)
- 1432-2323
- OpenAlex
- W2079174392
- Cited by
- 187
- References
- 20
- FWCI
- 3.11
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.