CIRSE Vascular Closure Device Registry
The DOI matches its Crossref record.
Abstract
PURPOSE: Vascular closure devices are routinely used after many vascular interventional radiology procedures. However, there have been no major multicenter studies to assess the safety and effectiveness of the routine use of closure devices in interventional radiology. METHODS: The CIRSE registry of closure devices with an anchor and a plug started in January 2009 and ended in August 2009. A total of 1,107 patients were included in the registry. RESULTS: Deployment success was 97.2%. Deployment failure specified to access type was 8.8% [95% confidence interval (95% CI) 5.0-14.5] for antegrade access and 1.8% (95% CI 1.1-2.9) for retrograde access (P = 0.001). There was no difference in deployment failure related to local PVD at the access site. Calcification was a reason for deployment failure in only <0.5% of patients. Postdeployment bleeding occurred in 6.4%, and most these (51.5%) could be managed with light manual compression. During follow-up, other device-related complications were reported in 1.3%: seven false aneurysms, three hematoma >5.9 cm, and two vessel occlusions. CONCLUSION: The conclusion of this registry of closure devices with an anchor and a plug is that the use of this device in interventional radiology procedures is safe, with a low incidence of serious access site complications. There seems to be no difference in complications between antegrade and retrograde access and other parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These results are not very dissimilar from the failure rates of VCDs reported in the current literature (1.1–8.7%) [11,14,15,16,17,21,23].”
In the citing paper
“the technical failure of VCDs is around 1.1–8.7% [11,14,15,16,17,21,23].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 9
- Kirchhof C, Schickel S, Schmidt-Lucke C, Schmidt-Lucke JA (2002) Local vascular complications after use of the hemostatic puncture closure device Angio-Seal. Vasa 31:101–106 · doi:10.1024/0301-1526.31.2.101
- Kapoor B, Panu A, Berscheid B (2007) Angio-seal in antegrade endovascular interventions: technical success and complications in a 55-patient series. Endovasc Ther 14:382–386 · doi:10.1583/06-2050.1
- Kadner A, Schmidli J, Schwegler I et al (2008) Complications associated with the arterial puncture closure device—Angio-Seal. Vasc Endovasc Surg 42:225–227 · doi:10.1177/1538574407312657
- Looby S, Keeling AN, McErlean A et al (2008) Efficacy and safety of the angioseal vascular closure device post antegrade puncture. Cardiovasc Intervent Radiol 31:558–562 · doi:10.1007/s00270-007-9281-5
- Eidt JF, Habibipour S, Saucedo JF et al (1999) Surgical complications from hemostatic puncture closure devices. Am J Surg 178:511–516 · doi:10.1016/s0002-9610(99)00246-9
- van der Steeg HJ, Berger P, Krasznai AG et al (2009) Acute arterial occlusion after deployment of the Angio-Seal closure device: is it as uncommon as we think? Eur J Vasc Endovasc Surg 38:715–717 · doi:10.1016/j.ejvs.2009.09.005
- Upponi SS, Ganeshan AG, Warakaulle DR et al (2007) Angioseal versus manual compression for haemostasis following peripheral vascular diagnostic and interventional procedures—a randomized controlled trial. Eur J Radiol 61:332–334 · doi:10.1016/j.ejrad.2006.09.007
- Katzenschlager R, Tischler R, Kalchhauser G et al (2009) Angio-Seal use in patients with peripheral arterial disease (ASPIRE). Angiology 60:536–538 · doi:10.1177/0003319708330007
- Mukhopadhyay K, Puckett MA, Roobottom CA (2005) Efficacy and complications of Angioseal in antegrade puncture. Eur J Radiol 56:409–412 · doi:10.1016/j.ejrad.2005.03.025
Cited by
Minici, R., Serra, R., Maglia, C., Guzzardi, G., Spinetta, M., Fontana, F., Venturini, M., & Laganà, D. (2023) · Journal of Personalized Medicine · doi:10.3390/jpm13050812 · Cited by 20
Metadata
- Authors
- Reekers, J. A., Müller-Hülsbeck, S., Libicher, M., Atar, E., Trentmann, J., Goffette, P., Borggrefe, J., Zeleňák, K., Hooijboer, P., & Belli, A.-M.
- Venue
- CardioVascular and Interventional Radiology
- Published
- 2010-10-28
- Volume
- 34
- Issue
- 1
- Pages
- 50-53
- ISSN
- 0174-1551
- 1432-086X
- Cited by
- 20
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.