Using computer-aided detection in mammography as a decision support
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: To evaluate an interactive computer-aided detection (CAD) system for reading mammograms to improve decision making. METHODS: A dedicated mammographic workstation has been developed in which readers can probe image locations for the presence of CAD information. If present, CAD findings are displayed with the computed malignancy rating. A reader study was conducted in which four screening radiologists and five non-radiologists participated to study the effect of this system on detection performance. The participants read 120 cases of which 40 cases had a malignant mass that was missed at the original screening. The readers read each mammogram both with and without CAD in separate sessions. Each reader reported localized findings and assigned a malignancy score per finding. Mean sensitivity was computed in an interval of false-positive fractions less than 10%. RESULTS: Mean sensitivity was 25.1% in the sessions without CAD and 34.8% in the CAD-assisted sessions. The increase in detection performance was significant (p = 0.012). Average reading time was 84.7 ± 61.5 s/case in the unaided sessions and was not significantly higher when interactive CAD was used (85.9 ± 57.8 s/case). CONCLUSION: Interactive use of CAD in mammography may be more effective than traditional CAD for improving mass detection without affecting reading time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
International evaluation of an AI system for breast cancer screening
McKinney, S. M., Sieniek, M., Godbole, V., Godwin, J., Antropova, N., Ashrafian, H., Back, T., Chesus, M., Corrado, G. S., Darzi, A., et al. (2020) · Nature · doi:10.1038/s41586-019-1799-6 · Cited by 3,287
Detection of Breast Cancer with Mammography: Effect of an Artificial Intelligence Support System
Rodríguez-Ruiz, A., Krupinski, E., Mordang, J.-J., Schilling, K., Heywang-Köbrunner, S. H., Sechopoulos, I., & Mann, R. M. (2019) · Radiology · doi:10.1148/radiol.2018181371 · Cited by 602
Moon, W. K., Lee, Y.-W., Ke, H.-H., Lee, S. H., Huang, C.-S., & Chang, R.-F. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105361 · Cited by 318
AI-based computer-aided diagnosis (AI-CAD): the latest review to read first
Fujita, H. (2020) · Radiological Physics and Technology · doi:10.1007/s12194-019-00552-4 · Cited by 300
Vasey, B., Ursprung, S., Beddoe, B., Taylor, E. H., Marlow, N., Bilbro, N., Watkinson, P., & McCulloch, P. (2021) · JAMA Network Open · doi:10.1001/jamanetworkopen.2021.1276 · Cited by 154
Metadata
- Authors
- Samulski, M., Hupse, R., Boetes, C., Mus, R. D. M., den Heeten, G. J., & Karssemeijer, N.
- Venue
- European Radiology
- Published
- 2010-06-09
- Volume
- 20
- Issue
- 10
- Pages
- 2323-2330
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2026174647
- Cited by
- 63
- References
- 0
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using computer-aided detection in mammography as a decision support. https://app.cochat.ai/papers/10.1007/s00330-010-1821-8
- The paper
- Samulski, M., Hupse, R., Boetes, C., Mus, R. D. M., den Heeten, G. J., & Karssemeijer, N. (2010). Using computer-aided detection in mammography as a decision support. European Radiology. https://doi.org/10.1007/s00330-010-1821-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.