Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVES: Multidetector CT (MDCT) has shown potential for prosthetic heart valve (PHV) assessment. We assessed the image quality of different PHV types to determine which valves are suitable for MDCT evaluation. METHODS: All ECG-gated CTs performed in our institutions since 2003 were reviewed for the presence of PHVs. After reconstruction in 3 specific PHV planes, image quality of the supravalvular, perivalvular, subvalvular and valvular regions was scored on a four-point scale (1 = non-diagnostic, 2 = moderate, 3 = good and 4 = excellent) by two independent observers. RESULTS: Eighty-four CT examinations (66 cardiac, 18 limited-dose aortic protocols) of 83 patients with a total of 91 PHVs in the aortic (n = 71), mitral (n = 17), pulmonary (n = 1) and tricuspid (n = 2) position were included. CT was performed on a 16-slice (n = 4), 64-slice (n = 28) or 256-slice (n = 52) MDCT system. Median image quality scores for the supra-, peri- and subvalvular regions and valvular detail were (3.5, 3.3, 3.5 and 3.5, respectively) for bileaflet PHV; (3.0, 3.0, 3.5 and 3.0, respectively) for Medtronic Hall PHV; (1.0, 1.0, 1.0 and 1.0, respectively) for Björk-Shiley and Sorin monoleaflet PHV and (3.5, 3.5, 4.0 and 2.0 respectively) for biological PHV. CONCLUSION: Currently implanted PHVs have good image quality on MDCT and are suitable for MDCT evaluation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lancellotti, P., Pibarot, P., Chambers, J., Edvardsen, T., Delgado, V., Dulgheru, R., Pepi, M., Cosyns, B., Dweck, M. R., Garbi, M., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew025 · Cited by 567
Han, B. K., Rigsby, C. K., Hlavacek, A., Leipsic, J., Nicol, E. D., Siegel, M. J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.004 · Cited by 211
La Grutta, L., Grassedonio, E., Gentile, G., Lo Re, G., Coppolino, F., La Tona, G., Galia, M., & Midiri, M. (2013) · Geriatric Imaging · doi:10.1007/978-3-642-35579-0_12 · Cited by 185
Han, B. K., Rigsby, C. K., Leipsic, J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., Raman, S. V., Crean, A. M., Nicol, E. D., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.007 · Cited by 158
Role of CT in the Pre- and Postoperative Assessment of Conotruncal Anomalies
Kumar, P., & Bhatia, M. (2022) · Radiology: Cardiothoracic Imaging · doi:10.1148/ryct.210089 · Cited by 16
Metadata
- Authors
- Habets, J., Symersky, P., van Herwerden, L. A., de Mol, B. A. J. M., Spijkerboer, A. M., Mali, W. P. T. M., & Budde, R. P. J.
- Venue
- European Radiology
- Published
- 2011-01-29
- Volume
- 21
- Issue
- 7
- Pages
- 1390-1396
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2165736652
- Cited by
- 73
- References
- 0
- FWCI
- 4.92
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.