The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Left and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MR
Open accessAbstract
OBJECTIVES: To compare Magnetic Resonance (MR) and Computed Tomography (CT) for the assessment of left (LV) and right (RV) ventricular functional parameters. METHODS: Seventy nine patients underwent both Cardiac CT and Cardiac MR. Images were acquired using short axis (SAX) reconstructions for CT and 2D cine b-SSFP (balanced-steady state free precession) SAX sequence for MR, and evaluated using dedicated software. RESULTS: CT and MR images showed good agreement: LV EF (Ejection Fraction) (52 ± 14% for CT vs. 52 ± 14% for MR; r = 0.73; p > 0.05); RV EF (47 ± 12% for CT vs. 47 ± 12% for MR; r = 0.74; p > 0.05); LV EDV (End Diastolic Volume) (74 ± 21 ml/m² for CT vs. 76 ± 25 ml/m² for MR; r = 0.59; p > 0.05); RV EDV (84 ± 25 ml/m² for CT vs. 80 ± 23 ml/m² for MR; r = 0.58; p > 0.05); LV ESV (End Systolic Volume)(37 ± 19 ml/m² for CT vs. 38 ± 23 ml/m² for MR; r = 0.76; p > 0.05); RV ESV (46 ± 21 ml/m² for CT vs. 43 ± 18 ml/m² for MR; r = 0.70; p > 0.05). Intra- and inter-observer variability were good, and the performance of CT was maintained for different EF subgroups. CONCLUSIONS: Cardiac CT provides accurate and reproducible LV and RV volume parameters compared with MR, and can be considered as a reliable alternative for patients who are not suitable to undergo MR. KEY POINTS: • Cardiac-CT is able to provide Left and Right Ventricular function. • Cardiac-CT is accurate as MR for LV and RV volume assessment. • Cardiac-CT can provide accurate evaluation of coronary arteries and LV and RV function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Pfeffer, M. A., Braunwald, E., Moyé, L. A., Basta, L., Brown, E. J., Cuddy, T. E., Davis, B. R., Geltman, E. M., Goldman, S., Flaker, G. C., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199209033271001 · Cited by 5,911
Prognostic significance of progression of coronary artery disease
Moise, A., Bourassa, M. G., Théroux, P., Taeymans, Y., Pasternac, A., Campeau, L., Bois, M. A., Dyrda, I., & David, P. R. (1985) · The American Journal of Cardiology · doi:10.1016/0002-9149(85)90722-2 · Cited by 56
Cited by
Leipsic, J., Abbara, S., Achenbach, S., Cury, R., Earls, J. P., Mancini, G. J., Nieman, K., Pontone, G., & Raff, G. L. (2014) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2014.07.003 · Cited by 1,072
Self-citationPennell, D. J., Udelson, J. E., Arai, A. E., Bozkurt, B., Cohen, A. R., Galanello, R., Hoffman, T. M., Kiernan, M. S., Lerakis, S., Piga, A., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829b2be6 · Cited by 394
Yamasaki, Y., Nagao, M., Yamamura, K., Yonezawa, M., Matsuo, Y., Kawanami, S., Kamitani, T., Higuchi, K., Sakamoto, I., Shiokawa, Y., et al. (2014) · European Radiology · doi:10.1007/s00330-014-3344-1 · Cited by 46
AI-Defined Cardiac Anatomy Improves Risk Stratification of Hybrid Perfusion Imaging
Miller, R. J. H., Shanbhag, A., Killekar, A., Lemley, M., Bednarski, B., Kavanagh, P. B., Feher, A., Miller, E. J., Bateman, T., Builoff, V., et al. (2024) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2024.01.006 · Cited by 33
Metadata
- Authors
- Maffei, E., Messalli, G., Martini, C., Nieman, K., Catalano, O., Rossi, A., Seitun, S., Guaricci, A. I., Tedeschi, C., Mollet, N. R., & Cademartiri, F.
- Venue
- European Radiology
- Published
- 2012-01-24
- Volume
- 22
- Issue
- 5
- Pages
- 1041-1049
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2046339192
- Cited by
- 178
- References
- 3
- FWCI
- 6.90
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Left and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MR. https://app.cochat.ai/papers/10.1007/s00330-011-2345-6
- The paper
- Maffei, E., Messalli, G., Martini, C., Nieman, K., Catalano, O., Rossi, A., Seitun, S., Guaricci, A. I., Tedeschi, C., Mollet, N. R., & Cademartiri, F. (2012). Left and right ventricle assessment with Cardiac CT: validation study vs. Cardiac MR. European Radiology. https://doi.org/10.1007/s00330-011-2345-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.