Can we reduce the workload of mammographic screening by automatic identification of normal exams with artificial intelligence? A feasibility study
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
PURPOSE: To study the feasibility of automatically identifying normal digital mammography (DM) exams with artificial intelligence (AI) to reduce the breast cancer screening reading workload. METHODS AND MATERIALS: A total of 2652 DM exams (653 cancer) and interpretations by 101 radiologists were gathered from nine previously performed multi-reader multi-case receiver operating characteristic (MRMC ROC) studies. An AI system was used to obtain a score between 1 and 10 for each exam, representing the likelihood of cancer present. Using all AI scores between 1 and 9 as possible thresholds, the exams were divided into groups of low- and high likelihood of cancer present. It was assumed that, under the pre-selection scenario, only the high-likelihood group would be read by radiologists, while all low-likelihood exams would be reported as normal. The area under the reader-averaged ROC curve (AUC) was calculated for the original evaluations and for the pre-selection scenarios and compared using a non-inferiority hypothesis. RESULTS: Setting the low/high-likelihood threshold at an AI score of 5 (high likelihood > 5) results in a trade-off of approximately halving (- 47%) the workload to be read by radiologists while excluding 7% of true-positive exams. Using an AI score of 2 as threshold yields a workload reduction of 17% while only excluding 1% of true-positive exams. Pre-selection did not change the average AUC of radiologists (inferior 95% CI > - 0.05) for any threshold except at the extreme AI score of 9. CONCLUSION: It is possible to automatically pre-select exams using AI to significantly reduce the breast cancer screening reading workload. KEY POINTS: • There is potential to use artificial intelligence to automatically reduce the breast cancer screening reading workload by excluding exams with a low likelihood of cancer. • The exclusion of exams with the lowest likelihood of cancer in screening might not change radiologists' breast cancer detection performance. • When excluding exams with the lowest likelihood of cancer, the decrease in true-positive recalls would be balanced by a simultaneous reduction in false-positive recalls.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
The benefits and harms of breast cancer screening: an independent review
(2012) · The Lancet · doi:10.1016/s0140-6736(12)61611-0 · Cited by 1,492
“Proving the null hypothesis” in clinical trials
Blackwelder, W. C. (1982) · Controlled Clinical Trials · doi:10.1016/0197-2456(82)90024-1 · Cited by 887
Breast-Cancer Tumor Size, Overdiagnosis, and Mammography Screening Effectiveness
Welch, H. G., Prorok, P. C., O’Malley, A. J., & Kramer, B. S. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1600249 · Cited by 699 · cited 1×
“Population-based screening programs with digital mammography (DM) reduce mortality from breast cancer due to the earlier detection of the disease [1, 2], but their efficiency is continuously under discussion [3, 4].”
BackgroundRodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Tan, T., Mertelmeier, T., et al. (2019) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy222 · Cited by 692 · cited 5×
“deep learning convolutional neural networks, feature classifiers, and image analysis algorithms to detect calcifications and soft tissue lesions in two different modules [14].”
BackgroundMethodInfluentialSelf-citationDiagnostic Accuracy of Digital Screening Mammography With and Without Computer-Aided Detection
Lehman, C. D., Wellman, R. D., Buist, D. S. M., Kerlikowske, K., Tosteson, A. N. A., & Miglioretti, D. L. (2015) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2015.5231 · Cited by 678
Smith, R. A., Cokkinides, V., Brooks, D., Saslow, D., & Brawley, O. W. (2010) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20063 · Cited by 660
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Detection of Breast Cancer with Mammography: Effect of an Artificial Intelligence Support System
Rodríguez-Ruiz, A., Krupinski, E., Mordang, J.-J., Schilling, K., Heywang-Köbrunner, S. H., Sechopoulos, I., & Mann, R. M. (2019) · Radiology · doi:10.1148/radiol.2018181371 · Cited by 602 · cited 1×
“For mammography evaluation, deep learning – based systems have demonstrated a stand-alone performance as good as radiologists [14], as well as a significant improvement of radiologists ’ breast cancer detection accuracy when used for decision support [15].”
BackgroundSelf-citationBroeders, M., Moss, S., Nyström, L., Njor, S., Jonsson, H., Paap, E., Massat, N., Duffy, S., Lynge, E., & Paci, E. (2012) · Journal of Medical Screening · doi:10.1258/jms.2012.012078 · Cited by 489
Self-citation
Cited by
Lång, K., Josefsson, V., Larsson, A.-M., Larsson, S., Högberg, C., Sartor, H., Hofvind, S., Andersson, I., & Rosso, A. (2023) · The Lancet Oncology · doi:10.1016/s1470-2045(23)00298-x · Cited by 598
Self-citationOverview of radiomics in breast cancer diagnosis and prognostication
Tagliafico, A. S., Piana, M., Schenone, D., Lai, R., Massone, A. M., & Houssami, N. (2020) · The Breast · doi:10.1016/j.breast.2019.10.018 · Cited by 309
Application of Artificial Intelligence in Medicine: An Overview
Liu, P.-R., Lu, L., Zhang, J.-Y., Huo, T.-T., Liu, S.-X., & Ye, Z.-W. (2021) · Current Medical Science · doi:10.1007/s11596-021-2474-3 · Cited by 258
“Similarly, breast cancer screening augmented with intelligent technology defeated clinical radiologists, showing a lower misdiagnosis rate and a workload decrease of 88% [14] ; additionally, the automatic preselect function significantly reduced the pressures on clinicians [15] .”
Artificial Intelligence in Breast Cancer Diagnosis and Personalized Medicine
Ahn, J. S., Shin, S., Yang, S.-A., Park, E. K., Kim, K. H., Cho, S. I., Ock, C.-Y., & Kim, S. (2023) · Journal of Breast Cancer · doi:10.4048/jbc.2023.26.e45 · Cited by 221
“Other studies have reported similar results, with a 47% reduction in workload, resulting in only 7% missed cancers [58].”
ResultA Deep Learning Model to Triage Screening Mammograms: A Simulation Study
Yala, A., Schuster, T., Miles, R., Barzilay, R., & Lehman, C. (2019) · Radiology · doi:10.1148/radiol.2019182908 · Cited by 210
“Recall rates from screening mammography have increased steadily concurrently explored in a recent reader study by Rodriguez-Ruiz et al (24), which used a commercial system and showed a simulated workload reduction of 17% with a drop of 1% in sensitivity and a noninferior radiologist AUC of 0.05 on an enriched data set.”
MethodInfluentialRaya-Povedano, J. L., Romero-Martín, S., Elías-Cabot, E., Gubern-Mérida, A., Rodríguez-Ruiz, A., & Álvarez-Benito, M. (2021) · Radiology · doi:10.1148/radiol.2021203555 · Cited by 177
CAD and AI for breast cancer—recent development and challenges
Chan, H.-P., Samala, R. K., & Hadjiiski, L. M. (2019) · The British Journal of Radiology · doi:10.1259/bjr.20190580 · Cited by 173
“In another study by the same group using the same data set, 115 the AI-based CAD system was used to assess the risk of malignancy of an exam by a score (1–10 scale).”
MethodHickman, S. E., Baxter, G. C., & Gilbert, F. J. (2021) · British Journal of Cancer · doi:10.1038/s41416-021-01333-w · Cited by 110
Optimizing risk-based breast cancer screening policies with reinforcement learning
Yala, A., Mikhael, P. G., Lehman, C., Lin, G., Strand, F., Wan, Y.-L., Hughes, K., Satuluru, S., Kim, T., Banerjee, I., et al. (2022) · Nature Medicine · doi:10.1038/s41591-021-01599-w · Cited by 103
A Review of Applications of Machine Learning in Mammography and Future Challenges
Batchu, S., Liu, F., Amireh, A., Waller, J., & Umair, M. (2021) · Oncology · doi:10.1159/000515698 · Cited by 41
Under-exploration of three-dimensional images leads to search errors for small salient targets
Lago, M. A., Jonnalagadda, A., Abbey, C. K., Barufaldi, B. B., Bakic, P. R., Maidment, A. D. A., Leung, W. K., Weinstein, S. P., Englander, B. S., & Eckstein, M. P. (2021) · Current Biology · doi:10.1016/j.cub.2020.12.029 · Cited by 22
Metadata
- Authors
- Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Teuwen, J., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Mertelmeier, T., Wallis, M. G., Andersson, I., Zackrisson, S., Sechopoulos, I., & Mann, R. M.
- Venue
- European Radiology
- Published
- 2019-04-16
- Volume
- 29
- Issue
- 9
- Pages
- 4825-4832
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2936218643
- Cited by
- 210
- References
- 31
- FWCI
- 10.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.