CoChat

Minimizing acquisition-related radiomics variability by image resampling and batch effect correction to allow for large-scale data analysis

Open access
Ligero, Marta, Jordi-Ollero, Olivia, Bernatowicz, Kinga, Garcia-Ruiz, Alonso, Delgado-Muñoz, Eric, Leiva, David, Mast, Richard, Suarez, Cristina, Sala-Llonch, Roser, Calvo, Nahum, Escobar, Manuel, Navarro-Martin, Arturo, Villacampa, Guillermo, Dienstmann, Rodrigo, Perez-Lopez, Raquel · 2021 · European Radiology
Cited by 191

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Objective: To identify CT-acquisition parameters accounting for radiomics variability and to develop a post-acquisition CT-image correction method to reduce variability and improve radiomics classification in both phantom and clinical applications. Methods: CT-acquisition protocols were prospectively tested in a phantom. The multi-centric retrospective clinical study included CT scans of patients with colorectal/renal cancer liver metastases. Ninety-three radiomics features of first order and texture were extracted. Intraclass correlation coefficients (ICCs) between CT-acquisition protocols were evaluated to define sources of variability. Voxel size, ComBat, and singular value decomposition (SVD) compensation methods were explored for reducing the radiomics variability. The number of robust features was compared before and after correction using two-proportion z test. The radiomics classification accuracy (K-means purity) was assessed before and after ComBat- and SVD-based correction. Results: Fifty-three acquisition protocols in 13 tissue densities were analyzed. Ninety-seven liver metastases from 43 patients with CT from two vendors were included. Pixel size, reconstruction slice spacing, convolution kernel, and acquisition slice thickness are relevant sources of radiomics variability with a percentage of robust features lower than 80%. Resampling to isometric voxels increased the number of robust features when images were acquired with different pixel sizes (p < 0.05). SVD-based for thickness correction and ComBat correction for thickness and combined thickness–kernel increased the number of reproducible features (p < 0.05). ComBat showed the highest improvement of radiomics-based classification in both the phantom and clinical applications (K-means purity 65.98 vs 73.20). Conclusion: CT-image post-acquisition processing and radiomics normalization by means of batch effect correction allow for standardization of large-scale data analysis and improve the classification accuracy. Key Points: • The voxel size (accounting for the pixel size and slice spacing), slice thickness, and convolution kernel are relevant sources of CT-radiomics variability. • Voxel size resampling increased the mean percentage of robust CT-radiomics features from 59.50 to 89.25% when comparing CT scans acquired with different pixel sizes and from 71.62 to 82.58% when the scans were acquired with different slice spacings. • ComBat batch effect correction reduced the CT-radiomics variability secondary to the slice thickness and convolution kernel, improving the capacity of CT-radiomics to differentiate tissues (in the phantom application) and the primary tumor type from liver metastases (in the clinical application).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00330-020-07174-0

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 191

Metadata

Authors
Ligero, M., Jordi-Ollero, O., Bernatowicz, K., Garcia-Ruiz, A., Delgado-Muñoz, E., Leiva, D., Mast, R., Suarez, C., Sala-Llonch, R., Calvo, N., Escobar, M., Navarro-Martin, A., Villacampa, G., Dienstmann, R., & Perez-Lopez, R.
Venue
European Radiology
Published
2020-09-09
Volume
31
Issue
3
Pages
1460-1470
ISSN
  • 0938-7994 (ISSN-L)
  • 1432-1084
OpenAlex
W3084293538
Cited by
191
References
7
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Minimizing acquisition-related radiomics variability by image resampling and batch effect correction to allow for large-scale data analysis. https://app.cochat.ai/papers/10.1007/s00330-020-07174-0
The paper
Ligero, M., Jordi-Ollero, O., Bernatowicz, K., Garcia-Ruiz, A., Delgado-Muñoz, E., Leiva, D., Mast, R., Suarez, C., Sala-Llonch, R., Calvo, N., Escobar, M., Navarro-Martin, A., Villacampa, G., Dienstmann, R., & Perez-Lopez, R. (2021). Minimizing acquisition-related radiomics variability by image resampling and batch effect correction to allow for large-scale data analysis. European Radiology. https://doi.org/10.1007/s00330-020-07174-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.