Radiation dose management systems—requirements and recommendations for users from the ESR EuroSafe Imaging initiative
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The European Directive 2013/59/Euratom requires member states of the European Union to ensure justification and optimisation of radiological procedures and store information on patient exposure for analysis and quality assurance. The EuroSafe Imaging campaign of the European Society of Radiology created a working group (WG) on “Dose Management” with the aim to provide European recommendations on the implementation of dose management systems (DMS) in clinical practice. The WG follows Action 4: “Promote dose management systems to establish local, national, and European diagnostic reference levels (DRL)” of the EuroSafe Imaging Call for Action 2018. DMS are designed for medical practitioners, radiographers, medical physics experts (MPE) and other health professionals involved in imaging to support their tasks and duties of radiation protection in accordance with local and national requirements. The WG analysed requirements and critical points when installing a DMS and classified the individual functions at different performance levels. Key Points: • DMS are very helpful software tools for monitoring patient exposure, optimisation, compliance with DRLs and quality assurance. • DMS can help to fulfil dosimetric aspects of the European Directive 2013/59/Euratom. • The EuroSafe WG analyses DMS requirements and gives recommendations for users.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A. (2017) · Annals of the ICRP · doi:10.1177/0146645317717209 · Cited by 1,043
Cited by
How to establish and use local diagnostic reference levels: an ESR EuroSafe Imaging expert statement
Damilakis, J., Frija, G., Brkljacic, B., Vano, E., Loose, R., Paulo, G., Brat, H., Tsapaki, V., & the European Society of Radiology (2023) · Insights into Imaging · doi:10.1186/s13244-023-01369-x · Cited by 76
“Abbreviations ALARA As low as reasonably achievable CTDI CT dose index DMS Dose management systems DRLs Diagnostic reference levels EC European Commission EFOMP European Federation of Organizations for Medical Physics EFRS European Federation of Radiographer Societies ESPR European Society of Paediatric Radiology ESR…”
BackgroundMethodSelf-citationOptimisation of Radiological Protection in Digital Radiology Techniques for Medical Imaging
154, I. P. (2023) · Annals of the ICRP · doi:10.1177/01466453231210646 · Cited by 37
Optimizing Communication of Radiation Exposure in Medical Imaging, the Radiologist Challenge
Pozzessere, C. (2023) · Tomography · doi:10.3390/tomography9020057 · Cited by 6
Metadata
- Authors
- Loose, R. W., Vano, E., Mildenberger, P., Tsapaki, V., Caramella, D., Sjöberg, J., Paulo, G., Torresin, A., Schindera, S., Frija, G., Damilakis, J., & on behalf of the European Society of Radiology (ESR)
- Venue
- European Radiology
- Published
- 2020-09-21
- Volume
- 31
- Issue
- 4
- Pages
- 2106-2114
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W3087507013
- Cited by
- 53
- References
- 1
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiation dose management systems—requirements and recommendations for users from the ESR EuroSafe Imaging initiative. https://app.cochat.ai/papers/10.1007/s00330-020-07290-x
- The paper
- Loose, R. W., Vano, E., Mildenberger, P., Tsapaki, V., Caramella, D., Sjöberg, J., Paulo, G., Torresin, A., Schindera, S., Frija, G., Damilakis, J., & on behalf of the European Society of Radiology (ESR). (2021). Radiation dose management systems—requirements and recommendations for users from the ESR EuroSafe Imaging initiative. European Radiology. https://doi.org/10.1007/s00330-020-07290-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.