Machine learning in cardiovascular radiology: ESCR position statement on design requirements, quality assessment, current applications, opportunities, and challenges
Open accessThe DOI matches its Crossref record; 28 of the 29 references it cites were found in a registry or an index.
Abstract
Machine learning offers great opportunities to streamline and improve clinical care from the perspective of cardiac imagers, patients, and the industry and is a very active scientific research field. In light of these advances, the European Society of Cardiovascular Radiology (ESCR), a non-profit medical society dedicated to advancing cardiovascular radiology, has assembled a position statement regarding the use of machine learning (ML) in cardiovascular imaging. The purpose of this statement is to provide guidance on requirements for successful development and implementation of ML applications in cardiovascular imaging. In particular, recommendations on how to adequately design ML studies and how to report and interpret their results are provided. Finally, we identify opportunities and challenges ahead. While the focus of this position statement is ML development in cardiovascular imaging, most considerations are relevant to ML in radiology in general. Key Points: • Development and clinical implementation of machine learning in cardiovascular imaging is a multidisciplinary pursuit. • Based on existing study quality standard frameworks such as SPIRIT and STARD, we propose a list of quality criteria for ML studies in radiology. • The cardiovascular imaging research community should strive for the compilation of multicenter datasets for the development, evaluation, and benchmarking of ML algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




![Fig. 5 Examples of application of ML in cardiac radiology. a Curved multiplanar reformation of CTAs with multiple plaques and a stent in the right coronary artery; standard hybrid iterative image reconstruction on the left, image processed with an ML algorithm with reduced noise on the right [21]. b Correctly identified Advisa device on a plain radiograph (left) with the according saliency map (right) that visualizes the neural networks attention [22]. c Segmentation of the LV on MRI by a DCNN with automatically detected contours in green color [23]. d Automated detection and quantification of calcifications on non-contrast CT scans (red: left anterior descending coronary artery; green: left circumflex coronary artery; yellow: thoracic aorta) [24]. e ML-based CT fractional flow reserve predicting obstructive stenosis in the mid left anterior descending coronary artery [25]](https://figures.cochat.ai/paper-figures/af3c6aa92ac3427290d448048262352b/machine-learning-in-cardiovascular-radiology-escr-position-statement-on-design-figure-5.jpg)


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Code for the complete model building pipeline should be published in well-documented scripts with computer environment requirements when possible7,8,13,14,16,19,20,24,25,27,33,50,62,64,65, including statements about any restrictions to access or re-use.”
From Guidelines and quality criteria for artificial intelligence-based prediction models in healthcare: a scoping review (2022) · cites this paper as [8]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The literature advises to discuss and explicitly report any identified sources of algorithmic bias, so that end users know for whom the AIPM’s predictive performance is subpar8,16.”
From Guidelines and quality criteria for artificial intelligence-based prediction models in healthcare: a scoping review (2022) · cites this paper as [8]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For example, the AIPM system might require dedicated and locally available hardware8.”
From Guidelines and quality criteria for artificial intelligence-based prediction models in healthcare: a scoping review (2022) · cites this paper as [8]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“It has been widely recommended to report any measures taken to prevent overfitting3,7,8,13,15.”
From Guidelines and quality criteria for artificial intelligence-based prediction models in healthcare: a scoping review (2022) · cites this paper as [8]
The cited source says what the claim attributes to it.
In the citing paper
“Developers are urged to clearly describe any differences between the development and validation data where possible14 and report other sources potentially affecting generalizability6,8,27.”
From Guidelines and quality criteria for artificial intelligence-based prediction models in healthcare: a scoping review (2022) · cites this paper as [8]
9 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
The FAIR Guiding Principles for scientific data management and stewardship
Wilkinson, M. D., Dumontier, M., Aalbersberg, I. J., Appleton, G., Axton, M., Baak, A., Blomberg, N., Boiten, J.-W., da Silva Santos, L. B., Bourne, P. E., et al. (2016) · Scientific Data · doi:10.1038/sdata.2016.18 · Cited by 18,423
SPIRIT 2013 Statement: Defining Standard Protocol Items for Clinical Trials
Chan, A.-W., Tetzlaff, J. M., Altman, D. G., Laupacis, A., Gøtzsche, P. C., Krleža-Jerić, K., Hróbjartsson, A., Mann, H., Dickersin, K., Berlin, J. A., et al. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-3-201302050-00583 · Cited by 7,363 · cited 1×
“Clinical trial protocols should conform to the Standard Protocol Items: Recommendations for Interventional Trials (SPIRIT) checklist [13].”
MethodUnderstanding bland altman analysis
Giavarina, D. (2015) · Biochemia Medica · doi:10.11613/bm.2015.015 · Cited by 4,706
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · BMJ · doi:10.1136/bmj.g7594 · Cited by 4,388 · cited 1×
“For prognostic studies, the Transparent Reporting of Multivariable Prediction Model for Individual Prognosis or Diagnosis (TRIPOD) guideline and checklist [15] should be followed.”
MethodCollins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · British Journal of Cancer · doi:10.1038/bjc.2014.639 · Cited by 3,293
A survey of deep neural network architectures and their applications
Liu, W., Wang, Z., Liu, X., Zeng, N., Liu, Y., & Alsaadi, F. E. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.12.038 · Cited by 3,239 · cited 1×
“An overview of commonly used ML models and their characteristics as well as approaches that can be used to deal with overfitting is provided by Liu et al in their review article [18].”
MethodMetrics for evaluating 3D medical image segmentation: analysis, selection, and tool
Taha, A. A., & Hanbury, A. (2015) · BMC Medical Imaging · doi:10.1186/s12880-015-0068-x · Cited by 2,920
Sheller, M. J., Edwards, B., Reina, G. A., Martin, J., Pati, S., Kotrotsou, A., Milchenko, M., Xu, W., Marcus, D., Colen, R. R., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-69250-1 · Cited by 1,646 · cited 1×
“An approach that allows for collaborative training of an ML model without exchanging data samples is “Federated learning” [8]: a copy of an algorithm is downloaded and local data used to further improve it.”
MethodSTARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · Radiology · doi:10.1148/radiol.2015151516 · Cited by 1,337
Cited by
de Hond, A. A. H., Leeuwenberg, A. M., Hooft, L., Kant, I. M. J., Nijman, S. W. J., van Os, H. J. A., Aardoom, J. J., Debray, T. P. A., Schuit, E., van Smeden, M., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-021-00549-7 · Cited by 499
“…recommended that already from the start the AIPM development team must cover a multidisciplinary technical, methodological and medical expertise 8,11,17,20,23,26,32,71 , consider data and project management 8,11,18,20,26 , and attend to the diversity of the anticipated end users of the AIPM…”
BackgroundMethodInfluentialArmoundas, A. A., Narayan, S. M., Arnett, D. K., Spector-Bagdady, K., Bennett, D. A., Celi, L. A., Friedman, P. A., Gollob, M. H., Hall, J. L., Kwitek, A. E., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001201 · Cited by 347
“10,11 Moreover, expertise in image interpretation is scarce, exacerbating inequities in access to high-quality patient care in underresourced areas, between lower and higher income populations, and between low-and rich-resource countries.”
BackgroundRajiah, P. S., François, C. J., & Leiner, T. (2023) · Radiology · doi:10.1148/radiol.223008 · Cited by 186
Self-citationWardlaw, J. M., Mair, G., von Kummer, R., Williams, M. C., Li, W., Storkey, A., Trucco, E., Liebeskind, D. S., Farrall, A., Bath, P. M., et al. (2022) · Stroke · doi:10.1161/strokeaha.121.036204 · Cited by 75
“Several societies have released their own guidelines and position statements.(26,27) The FDA https://www.”
BackgroundAutomatic coronary artery calcium scoring from unenhanced-ECG-gated CT using deep learning
Gogin, N., Viti, M., Nicodème, L., Ohana, M., Talbot, H., Gencer, U., Mekukosokeng, M., Caramella, T., Diascorn, Y., Airaud, J.-Y., et al. (2021) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2021.05.004 · Cited by 55
von Schacky, C. E., Wilhelm, N., Schäfer, V. S., Leonhardt, Y., Jung, M., Jungmann, P. M., Russe, M. F., Foreman, S. C., Gassert, F. G., Gassert, F. T., et al. (2022) · European Radiology · doi:10.1007/s00330-022-08764-w · Cited by 62
“A sample size of 80–100 cases for the external validation was included, similar to comparable research studies [14, 15].”
ResultGreco, F., Salgado, R. A., Hecke, W. V., BUONO, R. D., Parizel, P. M., & Mallio, C. A. (2022) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-945 · Cited by 48
Self-citationGuo, L., Zhou, C., Xu, J., Huang, C., Yu, Y., & Lu, G. (2024) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-024-00990-6 · Cited by 48
“We inferred that this due to the false positives or false negatives generated by the AI [16], which are more difficult for junior doctors to eliminate.”
BackgroundCT in Transcatheter-delivered Treatment of Valvular Heart Disease
Rudziński, P. N., Leipsic, J. A., Schoepf, U. J., Dudek, D., Schwarz, F., Andreas, M., Złahoda-Huzior, A., Thilo, C., Renker, M., Burt, J. R., et al. (2022) · Radiology · doi:10.1148/radiol.210567 · Cited by 29
Natale, L., Vliegenthart, R., Salgado, R. A., Bremerich, J., Budde, R. P. J., Dacher, J.-N., Francone, M., Kreitner, K., Loewe, C., Nikolaou, K., et al. (2023) · European Radiology · doi:10.1007/s00330-023-09533-z · Cited by 27
“These documents include topics ranging from quality and safety in cardiac CT and MRI [10, 16, 17], standardization of imaging methods and reporting [5, 23, 24], guidance on imaging during the COVID-19 pandemic [19], and position documents on innovations: machine learning and cardiac PET-MRI imaging [18, 21].”
MethodSelf-citationMasci, G. M., Iafrate, F., Ciccarelli, F., Pambianchi, G., Panebianco, V., Pasculli, P., Ciardi, M. R., Mastroianni, C. M., Ricci, P., Catalano, C., et al. (2021) · La radiologia medica · doi:10.1007/s11547-021-01371-7 · Cited by 25
Self-citationInforming a position statement on the use of artificial intelligence in dermatology in Australia
Caffery, L. J., Janda, M., Miller, R. E., Abbott, L. M., Arnold, C., Caccetta, T. P., Guitera, P., Shumack, S. P., Fernández‐Peñas, P., Mar, V., et al. (2022) · Australasian Journal of Dermatology · doi:10.1111/ajd.13946 · Cited by 19
Machine learning analysis: general features, requirements and cardiovascular applications
RICCIARDI, C., Cuocolo, R., Megna, R., CESARELLI, M., & Petretta, M. (2021) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.21.05637-4 · Cited by 9
Mothershaw, A., Smith, A. C., Perry, C., Brown, C. A., & Caffery, L. J. (2021) · Australian Journal of Otolaryngology · doi:10.21037/ajo-21-14 · Cited by 11
Machine Learning in Medical Imaging – Clinical Applications and Challenges in Computer Vision
Mehta, O., Liao, Z., Jenkinson, M., Carneiro, G., & Verjans, J. W. H. (2022) · Springer eBooks · doi:10.1007/978-981-19-1223-8_4 · Cited by 7
ESR Essentials: ten steps to cardiac MR—practice recommendations by ESCR
Emrich, T., Wintersperger, B. J., Greco, F. D., Suchá, D., Natale, L., Paar, M. H., & Francone, M. (2024) · European Radiology · doi:10.1007/s00330-024-10605-x · Cited by 6
Self-citationDesroche, L., Trimaille, A., Garban, T., & Bouleti, C. (2025) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2025.07.012 · Cited by 5
Mohammad‐Rahimi, H., Ramani, R. S., Setzer, F. C., Schwendicke, F., Pauwels, R., & Nosrat, A. (2026) · International Endodontic Journal · doi:10.1111/iej.70094 · Cited by 6
White, R., Demirer, M., Gupta, V., Sebro, R., Kusumoto, F. M., & Erdal, B. S. (2022) · Journal of medical imaging · doi:10.1117/1.jmi.9.5.054504 · Cited by 9
de Hond, A., Vosslamber, S. M., Lange, S., Engel, F., Lindhout, M., Noorlag, P., Steyerberg, E. W., Cinà, G., & Arbous, M. S. (2025) · Human Factors in Healthcare · doi:10.1016/j.hfh.2025.100095 · Cited by 5
de Bruin, J., Breimer, N., & Veenhuis, H. (2022) · Contemporary medical imaging · doi:10.1007/978-3-030-92087-6_51 · Cited by 4
Imoto, Y., Inui, T., Matsui, K., Watanabe, Y., Igari, T., Takeuchi, S., Kimura, M., Yagi, S., & Kawano, H. (2025) · Cureus · doi:10.7759/cureus.89446 · Cited by 10
“However, when introducing the system into clinical practice, we must take measures, such as calibration with facility data and limiting the types of imaging equipment [23,48], to prevent a decline in diagnostic performance.”
Salgado, R. A., Budde, R. P. J., & Saba, L. (2023) · British Journal of Radiology · doi:10.1259/bjr.20230484 · Cited by 2
Self-citationEcho Chambers: Bias and Representation in Cardiac Imaging Datasets for Artificial Intelligence
Gorijavolu, R., Jaiswal, N., Pratap, J. S., Madapati, K., López, M. D. P. A., Leite, M., Muwanguzi, D. P., Izath, N., Samsel, K., Shoyombo, I., et al. (2026) · Current Cardiology Reports · doi:10.1007/s11886-026-02406-z · Cited by 1
“…Proposed Requirements for Cardiovascular Imaging-Related Mul-timodal-AI Evaluation (PRIME) [ 21, 88], the European Society of Cardiovascular Radiology (ESCR) position statements on protocol harmonization [ 89–91], and the Checklist for Artificial Intelligence in Medical Imaging(CLAIM) [ 92, 93 ].”
Artificial Intelligence for Opportunistic Chest CT Screening and Prognostication
Sourlos, N., van Ooijen, P. M. A., & Vliegenthart, R. (2022) · Contemporary medical imaging · doi:10.1007/978-3-030-92087-6_45
Self-citationDu, T., Jiang, T., Grzegorzek, M., Xu, N., Sun, H., & Li, C. (2024) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm62325.2024.10821995
“…that CT-based segmentation of epicardial fat can significantly reduce the burden on clinicians and can serve as a stable assessment method for further exploring the relationship between epicardial fat and cardio-vascular event risk as well as metabolic diseases like metabolic syndrome [21], [22].”
COMPUTER-AIDED DIAGNOSIS AND DETECTION IN CHEST RADIOGRAPHY
Karačić, P. (2025) · Zdravstveni glasnik · doi:10.47960/2303-8616.2025.1.11.111
Machine learning applications on healthcare systems
Karunanithi, J., & Sundaravalli, E. (2025) · AIP conference proceedings · doi:10.1063/5.0293187
Kong, H., Wang, Z., Zhou, Z., Yu, D., Li, G., Li, J., Yuan, J., Li, X., & He, Y. (2025) · Journal of Cardiovascular Magnetic Resonance · doi:10.1016/j.jocmr.2025.101983
Automated prediction of major adverse cardiovascular events
Viti, M. (2022) · theses.fr (ABES) · doi:10.70675/152e1b37ze0c3z49efz832fza7886f46defe
Muthukumar, A., Schreck, A., Guerra‐Londono, C. E., Tabbara, A. K., & Uribe‐Marquez, S. (2026) · World Journal of Critical Care Medicine · doi:10.5492/wjccm.v15.i2.114201 · Cited by 1
ARTIFICIAL INTELLIGENCE IN THE DIAGNOSIS, TREATMENT AND PROGNOSIS OF CARDIOVASCULAR DISEASES
Soboleva, M. A., Kargaev, O. G., Chekurishvili, M. A., Tedeeva, M. V., Gopantsov, I. V., Zakaryan, N. G., Babayan, A. A., Tsogoeva, D. A., Tsagaraev, A. B., Yuzbasheva, V. E., et al. (2026) · Complex Issues of Cardiovascular Diseases · doi:10.17802/2306-1278-2026-15-4-225-241
Artificial Intelligence Reporting Guidelines in Radiology: A Systematic Review
Ochman, K., Korbaś, M., Kaczyńska, D., Mitręga, A., Zaucha, R., & Kufel, J. (2026) · Diagnostics · doi:10.3390/diagnostics16183054
“The ESCR position statement [42] combined high clarity of presentation (D4: 88.9”
InfluentialChapter 11 Optimization Techniques in Thermal Systems
Heeramana, J., Kumar, R. V., Tejaswib, S. P., & Babu, B. S. (2026) · De Gruyter eBooks · doi:10.1515/9783112230084-011
Metadata
- Authors
- Weikert, T., Francone, M., Abbara, S., Baessler, B., Choi, B. W., Gutberlet, M., Hecht, E. M., Loewe, C., Mousseaux, E., Natale, L., Nikolaou, K., Ordovas, K. G., Peebles, C., Prieto, C., Salgado, R., Velthuis, B., Vliegenthart, R., Bremerich, J., & Leiner, T.
- Affiliations
- University of Basel (CH)
- Policlinico Umberto I (IT)
- The University of Texas Southwestern Medical Center (US)
- University Hospital Zurich (CH)
- Yonsei University (KR)
- Leipzig University (DE)
- Weill Cornell Medicine (US)
- Medical University of Vienna (AT)
- Università Cattolica del Sacro Cuore (IT)
- Universitätsklinikum Tübingen (DE)
- University of California, San Francisco (US)
- University Hospital Southampton NHS Foundation Trust (GB)
- St Thomas' Hospital (GB)
- Antwerp University Hospital (BE)
- University Medical Center Utrecht (NL)
- University Medical Center Groningen (NL)
- Corresponding author
- Weikert, Thomas
- ORCID
- Venue
- European Radiology
- Published
- 2020-11-19
- Volume
- 31
- Issue
- 6
- Pages
- 3909-3922
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- PMC
- PMC8128798
- OpenAlex
- W3102655416
- Cited by
- 34
- References
- 29
- Citations by year
- 2026: 6 · 2025: 6 · 2024: 4 · 2023: 3 · 2022: 10 · 2021: 5
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- European Radiology (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Research Portal (King's College London) (publishedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, cc-by)
- IRIS Research product catalog (Sapienza University of Rome) (submittedVersion, cc-by)
- University of Groningen research database (University of Groningen / Centre for Information Technology) (submittedVersion, cc-by)
- Utrecht University Repository (Utrecht University) (submittedVersion, other-oa)
- YUHSpace (Yonsei University Medical Library) (submittedVersion, cc-by-nc-nd)
- PubliCatt (Università Cattolica del Sacro Cuore) (submittedVersion, other-oa)
- Zurich Open Repository and Archive (University of Zurich) (submittedVersion, cc-by)
- Zurich Open Repository and Archive (University of Zurich)
- Funders
- University of Basel
- Topics
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiomics and Machine Learning in Medical Imaging
- Keywords
- machine learning, cardiovascular imaging, alcoholic beverages, STARD, multi-center dataset
- MeSH terms
- Machine Learning, Algorithms, Humans, Radiography, Radiology, Societies, Medical
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.