To buy or not to buy—evaluating commercial AI solutions in radiology (the ECLAIR guidelines)
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Artificial intelligence (AI) has made impressive progress over the past few years, including many applications in medical imaging. Numerous commercial solutions based on AI techniques are now available for sale, forcing radiology practices to learn how to properly assess these tools. While several guidelines describing good practices for conducting and reporting AI-based research in medicine and radiology have been published, fewer efforts have focused on recommendations addressing the key questions to consider when critically assessing AI solutions before purchase. Commercial AI solutions are typically complicated software products, for the evaluation of which many factors are to be considered. In this work, authors from academia and industry have joined efforts to propose a practical framework that will help stakeholders evaluate commercial AI solutions in radiology (the ECLAIR guidelines) and reach an informed decision. Topics to consider in the evaluation include the relevance of the solution from the point of view of each stakeholder, issues regarding performance and validation, usability and integration, regulatory and legal aspects, and financial and support services. Key Points: • Numerous commercial solutions based on artificial intelligence techniques are now available for sale, and radiology practices have to learn how to properly assess these tools. • We propose a framework focusing on practical points to consider when assessing an AI solution in medical imaging, allowing all stakeholders to conduct relevant discussions with manufacturers and reach an informed decision as to whether to purchase an AI commercial solution for imaging applications. • Topics to consider in the evaluation include the relevance of the solution from the point of view of each stakeholder, issues regarding performance and validation, usability and integration, regulatory and legal aspects, and financial and support services.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Another look at measures of forecast accuracy
Hyndman, R. J., & Koehler, A. B. (2006) · International Journal of Forecasting · doi:10.1016/j.ijforecast.2006.03.001 · Cited by 5,757
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · BMJ · doi:10.1136/bmj.g7594 · Cited by 4,388
Moons, K. G. M., de Groot, J. A. H., Bouwmeester, W., Vergouwe, Y., Mallett, S., Altman, D. G., Reitsma, J. B., & Collins, G. S. (2014) · PLoS Medicine · doi:10.1371/journal.pmed.1001744 · Cited by 2,018 · cited 2×
“In general, one may refer to detailed guidelines [3, 21, 24], but several points are of particular importance:”
BackgroundChecklist for Artificial Intelligence in Medical Imaging (CLAIM): a guide for authors and reviewers
Mongan, J., Moy, L., & Kahn, C. E. (2020) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2020200029 · Cited by 1,443
Self-citationLiu, X., Cruz Rivera, S., Moher, D., Calvert, M. J., Denniston, A. K., The SPIRIT-AI and CONSORT-AI Working Group, SPIRIT-AI and CONSORT-AI Steering Group, Chan, A.-W., Darzi, A., Holmes, C., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1034-x · Cited by 1,421
Self-citationSTARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.246280 · Cited by 984
Cruz Rivera, S., Liu, X., Chan, A.-W., Denniston, A. K., Calvert, M. J., The SPIRIT-AI and CONSORT-AI Working Group, SPIRIT-AI and CONSORT-AI Steering Group, Darzi, A., Holmes, C., Yau, C., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-1037-7 · Cited by 933
Self-citationReporting of artificial intelligence prediction models
Collins, G. S., & Moons, K. G. M. (2019) · The Lancet · doi:10.1016/s0140-6736(19)30037-6 · Cited by 701
Geographic Distribution of US Cohorts Used to Train Deep Learning Algorithms
Kaushal, A., Altman, R., & Langlotz, C. (2020) · JAMA · doi:10.1001/jama.2020.12067 · Cited by 239
A Clinician's Guide to Artificial Intelligence: How to Critically Appraise Machine Learning Studies
Faes, L., Liu, X., Wagner, S. K., Fu, D. J., Balaskas, K., Sim, D. A., Bachmann, L. M., Keane, P. A., & Denniston, A. K. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.2.7 · Cited by 162 · cited 2×
“Nevertheless, AI-based products have specific features that require particular guidance (e.g., TRIPOD-ML, CONSORT-AI, SPIRIT-AI, and CLAIM guidelines) [1 – 6].”
Background
Cited by
Evaluation framework to guide implementation of AI systems into healthcare settings
Reddy, S., Rogers, W., Makinen, V.-P., Coiera, E., Brown, P., Wenzel, M., Weicken, E., Ansari, S., Mathur, P., Casey, A., et al. (2021) · BMJ Health & Care Informatics · doi:10.1136/bmjhci-2021-100444 · Cited by 230
Methods for clinical evaluation of artificial intelligence algorithms for medical diagnosis
Park, S. H., Han, K., Jang, H. Y., Park, J. E., Lee, J.-G., Kim, D. W., & Choi, J. (2023) · Radiology · doi:10.1148/radiol.220182 · Cited by 163
van de Sande, D., Van Genderen, M. E., Smit, J. M., Huiskens, J., Visser, J. J., Veen, R. E. R., van Unen, E., BA, O. H., Gommers, D., & Bommel, J. V. (2022) · BMJ Health & Care Informatics · doi:10.1136/bmjhci-2021-100495 · Cited by 135
Empirical data drift detection experiments on real-world medical imaging data
Kore, A., Abbasi Bavil, E., Subasri, V., Abdalla, M., Fine, B., Dolatabadi, E., & Abdalla, M. (2024) · Nature Communications · doi:10.1038/s41467-024-46142-w · Cited by 124
“To ensure the safe use of these algorithms, researchers and practitioners are developing a wide-set of evaluative and deployment best practices 1 – 3 .”
Oncologic Imaging and Radiomics: A Walkthrough Review of Methodological Challenges
Stanzione, A., Cuocolo, R., Ugga, L., Verde, F., Romeo, V., Brunetti, A., & Maurea, S. (2022) · Cancers · doi:10.3390/cancers14194871 · Cited by 64
Metadata
- Authors
- Omoumi, P., Ducarouge, A., Tournier, A., Harvey, H., Kahn, C. E., Louvet-de Verchère, F., Pinto Dos Santos, D., Kober, T., & Richiardi, J.
- Venue
- European Radiology
- Published
- 2021-03-05
- Volume
- 31
- Issue
- 6
- Pages
- 3786-3796
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W3134020135
- Cited by
- 167
- References
- 12
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: To buy or not to buy—evaluating commercial AI solutions in radiology (the ECLAIR guidelines). https://app.cochat.ai/papers/10.1007/s00330-020-07684-x
- The paper
- Omoumi, P., Ducarouge, A., Tournier, A., Harvey, H., Kahn, C. E., Louvet-de Verchère, F., Pinto Dos Santos, D., Kober, T., & Richiardi, J. (2021). To buy or not to buy—evaluating commercial AI solutions in radiology (the ECLAIR guidelines). European Radiology. https://doi.org/10.1007/s00330-020-07684-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.