Assessing GPT-4 multimodal performance in radiological image analysis
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Objectives: This study aims to assess the performance of a multimodal artificial intelligence (AI) model capable of analyzing both images and textual data (GPT-4V), in interpreting radiological images. It focuses on a range of modalities, anatomical regions, and pathologies to explore the potential of zero-shot generative AI in enhancing diagnostic processes in radiology. Methods: We analyzed 230 anonymized emergency room diagnostic images, consecutively collected over 1 week, using GPT-4V. Modalities included ultrasound (US), computerized tomography (CT), and X-ray images. The interpretations provided by GPT-4V were then compared with those of senior radiologists. This comparison aimed to evaluate the accuracy of GPT-4V in recognizing the imaging modality, anatomical region, and pathology present in the images. Results: GPT-4V identified the imaging modality correctly in 100% of cases (221/221), the anatomical region in 87.1% (189/217), and the pathology in 35.2% (76/216). However, the model’s performance varied significantly across different modalities, with anatomical region identification accuracy ranging from 60.9% (39/64) in US images to 97% (98/101) and 100% (52/52) in CT and X-ray images ( p < 0.001). Similarly, pathology identification ranged from 9.1% (6/66) in US images to 36.4% (36/99) in CT and 66.7% (34/51) in X-ray images ( p < 0.001). These variations indicate inconsistencies in GPT-4V’s ability to interpret radiological images accurately. Conclusion: While the integration of AI in radiology, exemplified by multimodal GPT-4, offers promising avenues for diagnostic enhancement, the current capabilities of GPT-4V are not yet reliable for interpreting radiological images. This study underscores the necessity for ongoing development to achieve dependable performance in radiology diagnostics. Clinical relevance statement: Although GPT-4V shows promise in radiological image interpretation, its high diagnostic hallucination rate (> 40%) indicates it cannot be trusted for clinical use as a standalone tool. Improvements are necessary to enhance its reliability and ensure patient safety. Key Points: GPT-4V’s capability in analyzing images offers new clinical possibilities in radiology . GPT-4V excels in identifying imaging modalities but demonstrates inconsistent anatomy and pathology detection . Ongoing AI advancements are necessary to enhance diagnostic reliability in radiological applications .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Convolutional Neural Networks for Radiologic Images: A Radiologist’s Guide
Soffer, S., Ben-Cohen, A., Shimon, O., Amitai, M. M., Greenspan, H., & Klang, E. (2019) · Radiology · doi:10.1148/radiol.2018180547 · Cited by 577
Self-citationCapabilities of GPT-4 on Medical Challenge Problems
Nori, H., King, N., McKinney, S. M., Carignan, D., & Horvitz, E. (2023) · arXiv · doi:10.48550/arxiv.2303.13375 · Cited by 509
Health system-scale language models are all-purpose prediction engines
Jiang, L. Y., Liu, X. C., Nejatian, N. P., Nasir-Moin, M., Wang, D., Abidin, A., Eaton, K., Riina, H. A., Laufer, I., Punjabi, P., et al. (2023) · Nature · doi:10.1038/s41586-023-06160-y · Cited by 460
Evaluating ChatGPT as an Adjunct for Radiologic Decision-Making
Rao, A., Kim, J., Kamineni, M., Pang, M., Lie, W., & Succi, M. D. (2023) · doi:10.1101/2023.02.02.23285399 · Cited by 257
The influence of clinical information on the reporting of CT by radiologists.
Leslie, A., Jones, A. J., & Goddard, P. R. (2000) · The British Journal of Radiology · doi:10.1259/bjr.73.874.11271897 · Cited by 172 · cited 1×
“Pathology diagnosis accuracy was also the lowest in US images, speci fi cally in testicular and renal US, which demonstrated 7.7% and 4.7% accuracy, respectively.”
InfluentialThe Future of AI and Informatics in Radiology: 10 Predictions
Langlotz, C. P. (2023) · Radiology · doi:10.1148/radiol.231114 · Cited by 56
Cited by
ChatGPT in healthcare: A taxonomy and systematic review
Li, J., Dada, A., Puladi, B., Kleesiek, J., & Egger, J. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108013 · Cited by 452
Takita, H., Kabata, D., Walston, S. L., Tatekawa, H., Saito, K., Tsujimoto, Y., Miki, Y., & Ueda, D. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01543-z · Cited by 203
CXR-LLaVA: a multimodal large language model for interpreting chest X-ray images
Lee, S., Youn, J., Kim, H., Kim, M., & Yoon, S. H. (2025) · European Radiology · doi:10.1007/s00330-024-11339-6 · Cited by 76
Medical multimodal large language models: A systematic review
Hu, Y., Xu, C., Lin, B., Yang, W., & Tang, Y. Y. (2025) · Intelligent Oncology · doi:10.1016/j.intonc.2025.09.005 · Cited by 14
Hamamoto, R., Koyama, T., Takahashi, S., Yasuda, T., Kobayashi, K., Akagi, Y., Kouno, N., Sudo, K., Hirata, M., Sunami, K., et al. (2026) · Journal of Hematology & Oncology · doi:10.1186/s13045-026-01781-y · Cited by 8
“Some studies have reported that attempts to directly generate “Impressions” in zero-shot settings yield suboptimal text and clinical metrics under rigorous cross-dataset evaluation, whereas others demonstrate comparable accuracy through careful configuration and task decomposition [87–90].”
Metadata
- Authors
- Brin, D., Sorin, V., Barash, Y., Konen, E., Glicksberg, B. S., Nadkarni, G. N., & Klang, E.
- Venue
- European Radiology
- Published
- 2024-08-30
- Volume
- 35
- Issue
- 4
- Pages
- 1959-1965
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W4402037259
- Cited by
- 112
- References
- 6
- FWCI
- 8.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.