The DOI matches its Crossref record; 72 of the 73 references it cites were found in a registry or an index.
Superparamagnetic iron oxide contrast agents: physicochemical characteristics and applications in MR imaging
Open accessAbstract
Superparamagnetic iron oxide MR imaging contrast agents have been the subjects of extensive research over the past decade. The iron oxide particle size of these contrast agents varies widely, and influences their physicochemical and pharmacokinetic properties, and thus clinical application. Superparamagnetic agents enhance both T1 and T2/T2* relaxation. In most situations it is their significant capacity to reduce the T2/T2* relaxation time to be utilized. The T1 relaxivity can be improved (and the T2/T2* effect can be reduced) using small particles and T1-weighted imaging sequences. Large iron oxide particles are used for bowel contrast [AMI-121 (i.e. Lumirem and Gastromark) and OMP (i.e. Abdoscan), mean diameter no less than 300 nm] and liver/spleen imaging [AMI-25 (i.e. Endorem and Feridex IV, diameter 80-150 nm); SHU 555A (i.e. Resovist, mean diameter 60 nm)]. Smaller iron oxide particles are selected for lymph node imaging [AMI-227 (i.e. Sinerem and Combidex, diameter 20-40 nm)], bone marrow imaging (AMI-227), perfusion imaging [NC100150 (i.e. Clariscan, mean diameter 20 nm)] and MR angiography (NC100150). Even smaller monocrystalline iron oxide nanoparticles are under research for receptor-directed MR imaging and magnetically labeled cell probe MR imaging. Iron oxide particles for bowel contrast are coated with insoluble material, and all iron oxide particles for intravenous injection are biodegradable. Superparamagnetic agents open up an important field for research in MR imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“SPION have been extensively used for diagnostic purposes, for visualizing tumors and metastases in liver, spleen and lymph nodes [137, 138], for angiography as a blood pool agent [139] and for visualizing inflammatory lesions like atherosclerotic plaques [140].”
From Iron oxide nanoparticles: Diagnostic, therapeutic and theranostic applications (2019) · cites this paper as [139]
Citations
Cites
Superparamagnetic iron oxide: pharmacokinetics and toxicity
Weissleder, R., Stark, D., Engelstad, B. L., Bacon, B., Compton, C. C., White, D., Jacobs, P. M., & Lewis, J. M. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.1.167 · Cited by 1,045
Weissleder, R., Elizondo, G., WITTENBERG, J., Rabito, C. A., Bengele, H. H., & Josephson, L. (1990) · Radiology · doi:10.1148/radiology.175.2.2326474 · Cited by 1,027
Jung, C. W., & Jacobs, P. M. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)00024-b · Cited by 625
Chouly, C., Pouliquen, D., Lucet, I., Jeune, J. J. L., & JALLET, P. (1996) · Journal of Microencapsulation · doi:10.3109/02652049609026013 · Cited by 468
Long-circulating iron oxides for MR imaging
Weissleder, R., Bogdanov, A. A., Jr., Neuwelt, E. A., & Papisov, M. I. (1995) · Advanced Drug Delivery Reviews · doi:10.1016/0169-409x(95)00033-4 · Cited by 399
Key factors in the acquisition of contrast kinetic data for oncology
Evelhoch, J. L. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3 · Cited by 366
Magnetically labeled cells can be detected by MR imaging
Weissleder, R., Cheng, H., Bogdanova, A., & Bogdanov, A. A., Jr. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070140 · Cited by 338
NMR imaging of changes in vascular morphology due to tumor angiogenesis
Dennie, J., Mandeville, J. B., Boxerman, J. L., Packard, S. D., Rosen, B. R., & Weisskoff, R. M. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400602 · Cited by 334
Senéterre, E., Taourel, P., Bouvier, Y., Pradel, J., BEERS, B. E. V., Daurès, J., Pringot, J., Mathieu, D. G., & Bruel, J. M. (1996) · Radiology · doi:10.1148/radiology.200.3.8756932 · Cited by 310
Ros, P. R., Freeny, P. C., Harms, S. E., Seltzer, S. E., Davis, P. L., Chan, T., Stillman, A. E., Muroff, L. R., Runge, V. M., & Nissenbaum, M. A. (1995) · Radiology · doi:10.1148/radiology.196.2.7617864 · Cited by 277
Bellin, M., Roy, C., Kinkel, K., Thoumas, D., Zaïm, S., Vanel, D., Tuchmann, C., Richard, F., Didier Jacqmin, D., Delcourt, A., et al. (1998) · Radiology · doi:10.1148/radiology.207.3.9609907 · Cited by 259
Anzai, Y., Blackwell, K. E., Hirschowitz, S. L., Rogers, J. W., Satō, Y., Yuh, W. T. C., Runge, V. M., Morris, M. R., McLachlan, S. J., & Lufkin, R. B. (1994) · Radiology · doi:10.1148/radiology.192.3.7520182 · Cited by 218
Phase I clinical evaluation of a new iron oxide MR contrast agent
McLachlan, S. J., Morris, M. R., Lucas, M. A., Fisco, R. A., Eakins, M. N., Fowler, D. R., Scheetz, R. B., & Olukotun, A. Y. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040313 · Cited by 194
Hepatic MRI with SPIO: detection and characterization of focal liver lesions
Reimer, P., & Tombach, B. (1998) · European Radiology · doi:10.1007/s003300050535 · Cited by 188
Weissleder, R., Lee, A. S., Khaw, B., Shen, T. T., & Brady, T. J. (1992) · Radiology · doi:10.1148/radiology.182.2.1732953 · Cited by 185
Clinical results with Resovist: a phase 2 clinical trial.
Reimer, P., Rummeny, E., Daldrup-Link, H. E., Balzer, T., Tombach, B., Berns, T., & Peters, P. E. (1995) · Radiology · doi:10.1148/radiology.195.2.7724772 · Cited by 182
Hahn, P. F., Stark, D. D., Lewis, J. M., Saini, S., Elizondo, G., Weissleder, R., Fretz, C. J., & Ferrucci, J. T. (1990) · Radiology · doi:10.1148/radiology.175.3.2343116 · Cited by 178
Tiefenauer, L., Kuehne, G., & Andres, R. Y. (1993) · Bioconjugate Chemistry · doi:10.1021/bc00023a007 · Cited by 156
Polyclonal human immunoglobulin G labeled with polymeric iron oxide: antibody MR imaging.
Weissleder, R., Lee, A. S., Fischman, A. J., Reimer, P., Shen, T. T., Wilkinson, R., Callahan, R. J., & Brady, T. J. (1991) · Radiology · doi:10.1148/radiology.181.1.1887040 · Cited by 153
Cellular Uptake and Trafficking of a Prototypical Magnetic Iron Oxide Label In Vitro
Schulze, E., Ferrucci, J. T., Poss, K., LAPOINTE, L., Bogdanova, A., & Weissleder, R. (1995) · Investigative Radiology · doi:10.1097/00004424-199510000-00006 · Cited by 142
Remsen, L. G., McCormick, C. I., Roman-Goldstein, S., Nilaver, G., Weissleder, R., Bogdanov, A. A., Jr., Hellström, K. E., Kroll, R. A., & Neuwelt, E. A. (1996) · PubMed Central · Cited by 123
Stillman, A. E., Wilke, N. M., Li, D., Haacke, E. M., & McLachlan, S. J. (1996) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199601000-00011 · Cited by 115
Experimental lymph node metastases: enhanced detection with MR lymphography.
Weissleder, R., Elizondo, G., Josephson, L., Compton, C. C., Fretz, C. J., Stark, D. D., & Ferrucci, J. T. (1989) · Radiology · doi:10.1148/radiology.171.3.2717761 · Cited by 115
Bone marrow: ultrasmall superparamagnetic iron oxide for MR imaging.
Senéterre, E., Weissleder, R., Jaramillo, D., Reimer, P., Lee, A. S., Brady, T. J., & WITTENBERG, J. (1991) · Radiology · doi:10.1148/radiology.179.2.2014305 · Cited by 109
Saini, S., Edelman, R. R., Sharma, P. K., Li, W., Mayo-Smith, W. W., Slater, G. J., Eisenberg, P. J., & Hahn, P. F. (1995) · American Journal of Roentgenology · doi:10.2214/ajr.164.5.7717222 · Cited by 103
Cerdán, S., Lötscher, H. R., Künnecke, B., & Seelig, J. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910120202 · Cited by 98
MR contrast material for vascular enhancement: value of superparamagnetic iron oxide.
Mayo-Smith, W. W., Saini, S., Slater, G. J., Kaufman, J. A., Sharma, P., & Hahn, P. F. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.1.8571910 · Cited by 91
Dose and scanning delay using USPIO for central nervous system macrophage imaging
Dousset, V., Gomez, C., Petry, K. G., Delalande, C., & Caillé, J. (1999) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/bf02594597 · Cited by 83
van Bruggen, N., Busch, E. W., Palmer, J. T., Williams, S., & de Crespigny, A. J. (1998) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199811000-00003 · Cited by 77
Grangier, C., Tourniaire, J., Mentha, G., Schiau, R., Howart, N., Chachuat, A., Grossholz, M., & Terrier, F. (1994) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199411000-00008 · Cited by 75
Hamberg, L. M., Boccalini, P., Stranjalis, G., Hunter, G. J. S., Huang, Z., Halpern, E. F., Weisskoff, R. M., Moskowitz, M. A., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350207 · Cited by 72
Canet‐Soulas, E., Revel, D., Forrat, R., Baldy, C., de Lorgeril, M., Sebbag, L., Vallée, J., Didier, D., & AMIEL, M. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90241-5 · Cited by 70
Imaging of nodal metastases in the head and neck
Anzai, Y., Brunberg, J. A., & Lufkin, R. B. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070503 · Cited by 70
Ahlström, K. H., Johansson, L. O. M., Rodenburg, J. B., Ragnarsson, A., Åkeson, P., & Børseth, A. (1999) · Radiology · doi:10.1148/radiology.211.3.r99jn10865 · Cited by 69
Harisinghani, M. G., Saini, S., Weissleder, R., Halpern, E. F., Schima, W., Rubin, D. L., Stillman, A. E., Sica, G. T., Small, W. C., & Hahn, P. F. (1997) · Radiology · doi:10.1148/radiology.202.3.9051017 · Cited by 66
Abdominal MR: liver and pancreas
Bartolozzi, C., Lencioni, R. A., Donati, F., & Cioni, D. (1999) · European Radiology · doi:10.1007/s003300050876 · Cited by 62
Mion-ASF: Biokinetics of an MR receptor agent
Schaffer, B. K., Linker, C., Papisov, M. I., Tsai, E., Nossiff, N. D., Shibata, T., Bogdanov, A. A., Jr., Brady, T. J., & Weissleder, R. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90074-n · Cited by 61
Sharma, R., Saini, S., Ros, P. R., Hahn, P. F., Small, W. C., de Lange, E. E., Stillman, A. E., Edelman, R. R., Runge, V. M., Outwater, E. K., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199902)9:2 · Cited by 53
Pancreatic receptors: initial feasibility studies with a targeted contrast agent for MR imaging.
Reimer, P., Weissleder, R., Shen, T., Knoefel, W. T., & Brady, T. J. (1994) · Radiology · doi:10.1148/radiology.193.2.7972773 · Cited by 53
Use of an intravascular T1 contrast agent to improve MR cine myocardial‐blood pool definition in man
Stillman, A. E., Wilke, N. M., & Jerosch‐Herold, M. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070425 · Cited by 53
Daldrup-Link, H. E., Link, T. M., Blasius, S., Strozyk, A., K�nemann, S., J�rgens, H., & Rummeny, E. J. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199905)9:5 · Cited by 53
Vassallo, P., Matei, C., Heston, W. D. W., McLachlan, S. J., Koutcher, J. A., & Castellino, R. A. (1995) · Investigative Radiology · doi:10.1097/00004424-199512000-00003 · Cited by 50
Saeed, M., Wendland, M. F., Engelbrecht, M. R. W., Sakuma, H., & Higgins, C. B. (1998) · European Radiology · doi:10.1007/s003300050512 · Cited by 47
Berry, I., Benderbous, S., Ranjeva, J., Gracia‐Meavilla, D., MANELFE, C., & Bihan, D. L. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360313 · Cited by 47
Ichikawa, T., Arbab, A. S., Araki, T., Touyama, K., Haradome, H., Hachiya, J., Yamaguchi, M., Kumagai, H., & Aoki, S. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.173.1.10397128 · Cited by 37
Mühler, A., Freise, C. E., Kuwatsuru, R., Rosenau, W., Liu, T., Mintorovitch, J., Clémеnt, O., Vexler, V. S., Mahboubi, S., & Lang, P. K. (1993) · Radiology · doi:10.1148/radiology.186.1.8416555 · Cited by 34
Determinants of in vivo MR imaging of slow axonal transport.
van Everdingen, K. J., Enochs, W. S., Bhide, P. G., Nossiff, N. D., Papisov, M. I., Bogdanov, A. A., Jr., Brady, T. J., & Weissleder, R. (1994) · Radiology · doi:10.1148/radiology.193.2.7526413 · Cited by 31
Trillaud, H., Grenier, N., Degrèze, P., Louail, C., Chambon, C., & Franconi, J. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030115 · Cited by 31
Ferrimagnetic susceptibility contrast agents.
Bach-Gansmo, T. (1993) · PubMed · Cited by 29
USPIO-Enhanced MR imaging of glycerol-induced acute renal failure in the rabbit
Trillaud, H., Degrèze, P., Combe, C., Deminière, C., Palussière, J., Benderbous, S., & Grenier, N. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00114-i · Cited by 28
White, C. A., Thomson, S. A., Cooper, L. T., Endert, P. V., Tampé, R., Coupar, B. E. H., Li, Q., Parsons, P. G., Moss, D. J., & Khanna, R. (1998) · International Journal of Cancer · doi:10.1002/(sici)1097-0215(19980209)75:4 · Cited by 27
Superparamagnetically labelled neutrophils as potential abscess-specific contrast agent for MRI
Krieg, F. M., Andres, R. Y., & Winterhalter, K. H. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00111-f · Cited by 26
Magnetic Resonance Imaging of Abscesses Using Lipid-Coated Iron Oxide Particles
Chan, T. W., Eley, C. G. S., LIBERTI, P., SO, A., & Kressel, H. Y. (1992) · Investigative Radiology · doi:10.1097/00004424-199206000-00009 · Cited by 25
Suzuki, M., Honda, H., Kobayashi, T., Wakabayashi, T., Yoshida, J., & Takahashi, M. (1996) · PubMed · Cited by 25
Brain water diffusion in normal and creatine-supplemented rats during transient global ischemia
Wick, M., Fujimori, H., Michaelis, T., & Frahm, J. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199910)42:4 · Cited by 25
Leveille-Webster, C., Rogers, J., & Arias, I. M. (1996) · Hepatology · doi:10.1002/hep.510230646 · Cited by 24
Apparent water diffusion measurements in electrically stimulated neural tissue
Gulani, V., Iwamoto, G. A., & Lauterbur, P. C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199902)41:2 · Cited by 22
Comparative efficacy of and sequence choice for two oral contrast agents used during MR imaging.
Grubnic, S., Padhani, A. R., Revell, P., & Husband, J. E. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.173.1.10397122 · Cited by 21
Kato, N., Takahashi, M., TSUJI, T., Ihara, S., Bräutigam, M., & Miyazawa, T. (1999) · Investigative Radiology · doi:10.1097/00004424-199909000-00001 · Cited by 20
Hilfiker, P. R., Zimmermann-Paul, G. G., Schmidt, M., Klotz, H. P., Kacl, G. M., & Debatin, J. F. (1998) · Radiology · doi:10.1148/radiology.209.3.9844672 · Cited by 18
MRI in acute cerebral ischaemia: perfusion imaging with superparamagnetic iron oxide in a rat model
Forsting, M., Reith, W., Dörfler, A., von Kummer, R., Hacke, W., & Sartor, K. J. (1994) · Neuroradiology · doi:10.1007/bf00599188 · Cited by 18
MR Imaging of Neuronal Transport in the Guinea Pig Facial Nerve: Initial Findings
Petropoulos, A. E., Schaffer, B., Cheney, M. L., Enochs, S., Zimmer, C., & Weissleder, R. (1995) · Acta Oto-Laryngologica · doi:10.3109/00016489509139358 · Cited by 18
Evaluation of an ultrasmall superparamagnetic iron oxide in MRI in a bone tumor model in rabbits
Bush, C. H., Mladinich, C. R. J., & Montgomery, W. J. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070320 · Cited by 17
Weishaupt, D., Hilfiker, P. R., Schmidt, M., & Debatin, J. F. (1999) · CardioVascular and Interventional Radiology · doi:10.1007/s002709900396 · Cited by 16
Kreft, B. P., Tanimoto, A., Leffler, S., Finn, J. P., Øksendal, A. N., & Stark, D. D. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040324 · Cited by 13
Rozenman, Y., Zou, X., & Kantor, H. L. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90538-w · Cited by 12
Bondareff, W., Matsuyama, S. S., & Dell’Albani, P. (1998) · Journal of Neuroscience Research · doi:10.1002/(sici)1097-4547(19980601)52:5 · Cited by 11
4827945 Biologically degradable superparamagnetic materials for use in clinical applications
Groman, E., Josephson, L., & Lewis, J. M. (1991) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(91)90026-i · Cited by 8
Dose and scanning delay using USPIO for central nervous system macrophage imaging
Dousset, V. (1999) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1016/s1352-8661(99)00028-9 · Cited by 5
Leveille-Webster, C. (1996) · Hepatology · doi:10.1053/jhep.1996.v23.pm0008675187 · Cited by 2
Wansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Buckley (1999) · doi:10.1002/(sici)1522-2594(199901)41:1
Cited by
Sorted by citations
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
Gupta, A. K., & Gupta, M. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.012 · Cited by 6,906
Magnetic nanoparticles in MR imaging and drug delivery
Sun, C., Lee, J. S. H., & Zhang, M. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.018 · Cited by 2,642
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Springer eBooks · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,571
Design and fabrication of magnetic nanoparticles for targeted drug delivery and imaging
Omid Veiseh, A., Gunn, J., & Zhang, M. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.002 · Cited by 1,854
Metadata
- Authors
- Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P.
- Affiliations
- Erasmus MC (NL)
- Venue
- European Radiology
- Published
- 2001-05-03
- Volume
- 11
- Issue
- 11
- Pages
- 2319-2331
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2086171977
- Cited by
- 1,381
- References
- 73
- Citations by year
- 2026: 7 · 2025: 26 · 2024: 26 · 2023: 29 · 2022: 40 · 2021: 42 · 2020: 57 · 2019: 64 · 2018: 60 · 2017: 68 · 2016: 62 · 2015: 83 · 2014: 88 · 2013: 87 · 2012: 114
- FWCI
- 15.26
- Type
- journal article
- Language
- en
- Open access
- green
- pure.eur.nl
- Licence
- other-oa
- www.springer.com/tdm (tdm)
- Locations
- European Radiology (publishedVersion)
- PubMed (publishedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (publishedVersion, other-oa)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion, other-oa)
- RePub (Erasmus University Rotterdam) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Materials Science › Materials Chemistry › Lanthanide and Transition Metal Complexes
- Keywords
- superparamagnetic iron oxide nanoparticles, MRI contrast agents, particle size, T1 relaxivity, lymph node imaging, bone marrow imaging, perfusion imaging, magnetic resonance angiography, magnetically labeled cells, biodegradable nanoparticles, pharmacokinetics
- MeSH terms
- Contrast Media, Ferric Compounds, Magnetic Resonance Imaging, Magnetics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review