Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 224

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

The APPLE score: a novel and simple score for the prediction of rhythm outcomes after catheter ablation of atrial fibrillation

Open access
Kornej, Jelena, Hindricks, Gerhard, Shoemaker, M. Benjamin, Husser, Daniela, Arya, Arash, Sommer, Philipp, Rolf, Sascha, Saavedra, Pablo, Kanagasundram, Arvindh, Patrick Whalen, S., Montgomery, Jay, Ellis, Christopher R., Darbar, Dawood, Bollmann, Andreas · 2015 · Clinical Research in Cardiology

Abstract

BackgroundRecurrent atrial fibrillation (AF) occurs in up to 50 % of patients within 1 year after catheter ablation, and a clinical risk score to predict recurrence remains a critical unmet need. The aim of this study was to (1) develop a simple score for the prediction of rhythm outcome following catheter ablation; (2) compare it with the CHADS2 and CHA2DS2-VASc scores, and (3) validate it in an external cohort.MethodsRhythm outcome between 3 and 12 months after AF catheter ablation were documented. The APPLE score [one point for age >65 years, persistent AF, impaired eGFR (<60 ml/min/1.73 m2), LA diameter ≥43 mm, EF < 50 %] was associated with AF recurrence and was validated in an external cohort in 261 patients with comparable ablation and follow-up.ResultsIn 1145 patients (60 ± 10 years, 65 % male, 62 % paroxysmal AF) the APPLE score showed better prediction of AF recurrences (AUC 0.634, 95 % CI 0.600–0.668, p < 0.001) than CHADS2 (AUC 0.538) and CHA2DS2-VASc (AUC 0.542). Compared to patients with an APPLE score of 0, the odds ratio for AF recurrences was 1.73, 2.79 and 4.70 for APPLE scores 1, 2, or ≥3, respectively (all p < 0.05). In the external validation cohort, the APPLE score showed similar results (AUC 0.624, 95 % CI 0.562–0.687, p < 0.001).ConclusionsThe novel APPLE score is superior to the CHADS2 and CHA2DS2-VASc scores for prediction of rhythm outcome after catheter ablation. It holds promise as a useful tool to identify patients with low, intermediate, and high risk for AF recurrence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00392-015-0856-x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 224

Metadata

Authors
Kornej, J., Hindricks, G., Shoemaker, M. B., Husser, D., Arya, A., Sommer, P., Rolf, S., Saavedra, P., Kanagasundram, A., Patrick Whalen, S., Montgomery, J., Ellis, C. R., Darbar, D., & Bollmann, A.
Venue
Clinical Research in Cardiology
Published
2015-04-17
Volume
104
Issue
10
Pages
871-876
ISSN
  • 1861-0684 (ISSN-L)
  • 1861-0692
OpenAlex
W1970633047
Cited by
224
References
5
FWCI
8.25
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The APPLE score: a novel and simple score for the prediction of rhythm outcomes after catheter ablation of atrial fibrillation. https://app.cochat.ai/papers/10.1007/s00392-015-0856-x
The paper
Kornej, J., Hindricks, G., Shoemaker, M. B., Husser, D., Arya, A., Sommer, P., Rolf, S., Saavedra, P., Kanagasundram, A., Patrick Whalen, S., Montgomery, J., Ellis, C. R., Darbar, D., & Bollmann, A. (2015). The APPLE score: a novel and simple score for the prediction of rhythm outcomes after catheter ablation of atrial fibrillation. Clinical Research in Cardiology. https://doi.org/10.1007/s00392-015-0856-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.