CoChat

Treatment outcomes and compliance according to obesity in patients with obstructive sleep apnea

Kim, Heejin, Kim, Min-Su, Lee, Ji-Eun, Kim, Jeong-Whun, Lee, Chul Hee, Yoon, In-Young, Rhee, Chae-Seo · 2013 · European Archives of Oto-Rhino-Laryngology

The DOI matches its Crossref record; 34 of the 35 references it cites were found in a registry or an index.

Abstract

The objective of this study was to assess treatment outcomes and compliance according to obesity among groups of patients with obstructive sleep apnea (OSA) receiving different treatments. A total of 297 patients with OSA treated between 2006 and 2009 underwent pre- and post-treatment polysomnography. One hundred and fifty-one patients were treated with continuous airway positive pressure (CPAP), 76 with mandible advancement device (MAD), and 70 with oropharyngeal surgery. All patients were classified according to obesity. Treatment success rate and compliance of CPAP were analyzed according to obesity. For each treatment modality, the overall treatment success rate was not significantly different between obese and non-obese patients. However, the oxygen desaturation index was different in patients who were treated with MAD and surgery. Additionally, obese patients with severe OSA showed an unfavorable response to CPAP treatment. For CPAP compliance, obese patients showed a tendency to be highly compliant with CPAP treatment at 12 months than non-obese patients. This study showed that obesity might be a factor in determining the success or failure of treatment. Additionally, obesity may be a predictive factor to determine CPAP compliance.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00405-013-2397-0

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 34 references

Cited by

See all 15

Metadata

Authors
Kim, H., Kim, M.-S., Lee, J.-E., Kim, J.-W., Lee, C. H., Yoon, I.-Y., & Rhee, C.-S.
Affiliations
  • Seoul National University (KR)
  • Chosun University Hospital (KR)
Corresponding author
Rhee, Chae-Seo
Venue
European Archives of Oto-Rhino-Laryngology
Published
2013-02-28
Volume
270
Issue
11
Pages
2885-2890
ISSN
  • 0937-4477 (ISSN-L)
  • 1434-4726
OpenAlex
W1966560710
Cited by
15
References
35
Citations by year
2024: 1 · 2023: 1 · 2022: 2 · 2021: 1 · 2020: 3 · 2019: 1 · 2017: 2 · 2015: 2 · 2014: 2
FWCI
0.93
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • European Archives of Oto-Rhino-Laryngology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
  • Health Sciences › Dentistry › Oral Surgery › Temporomandibular Joint Disorders
Keywords
obstructive sleep apnea, obesity, CPAP adherence, CPAP treatment outcomes, mandibular advancement device, oropharyngeal surgery, oxygen desaturation index, treatment success rate, polysomnography
MeSH terms
Adult, Aged, Aged, 80 and over, Equipment and Supplies, Female, Humans, Male, Middle Aged, Obesity, Oropharynx, Palate, Patient Compliance, Otorhinolaryngologic Surgical Procedures, Uvula, Body Mass Index, Treatment Outcome, Polysomnography, Mandibular Advancement, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Treatment outcomes and compliance according to obesity in patients with obstructive sleep apnea. https://app.cochat.ai/papers/10.1007/s00405-013-2397-0
The paper
Kim, H., Kim, M.-S., Lee, J.-E., Kim, J.-W., Lee, C. H., Yoon, I.-Y., & Rhee, C.-S. (2013). Treatment outcomes and compliance according to obesity in patients with obstructive sleep apnea. European Archives of Oto-Rhino-Laryngology. https://doi.org/10.1007/s00405-013-2397-0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.