Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Selective upper airway stimulation for obstructive sleep apnea: a single center clinical experience

Heiser, Clemens, Knopf, Andreas, Bas, Murat, Gahleitner, Constanze, Hofauer, Benedikt · 2017 · European Archives of Oto-Rhino-Laryngology

Abstract

Selective upper airway stimulation (UAS) is a novel therapy for patients with obstructive sleep apnea (OSA). The aim of this study was to analyze the application and outcome of UAS in patients with moderate to severe OSA in the clinical routine of a tertiary referral center. The design of this study is single-center, prospective clinical trial. Thirty-one patients who received a UAS device (Inspire Medical Systems) were included. Treatment outcome was evaluated at 2, 3, 6, and 12 months after surgery. Data collection included demographics, body mass index (BMI), apnea hypopnea index (AHI), oxygen saturation and desaturation index (ODI), Epworth Sleepiness Score (ESS), adverse events, and adherence to therapy. Sher criteria were used to evaluate treatment response. The mean age was 59.6 years with thirty patients being male. Mean BMI was 28.8 kg/m 2 . The mean pre-implantation AHI of 32.9/h could be reduced to 7.1/h after 12 months (p < 0.001). The mean pre-implantation ODI of 30.7/h could be reduced to 9.9/h after 12 months (p = 0.004). The mean pre-implantation ESS of 12.6 could be reduced to 5.9 after 12 months (p = 0.006). Serious adverse events did not occur. Therapy adherence was a usage of 6.6 h/night after 12 months. OSA severity and subjective daytime sleepiness were improved in patients with moderate to severe OSA after receiving UAS therapy. Patients maintained high adherence to therapy use after 12 months. It is encouraging that UAS has been shown to be successfull…

Overview

Integrity signals

Registry

Crossref · 10.1007/s00405-016-4297-6

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 34 references

Cited by

See all 94

Metadata

Authors
Heiser, C., Knopf, A., Bas, M., Gahleitner, C., & Hofauer, B.
Affiliations
TUM Klinikum (DE)
Corresponding author
Hofauer, Benedikt
Venue
European Archives of Oto-Rhino-Laryngology
Published
2016-09-12
Volume
274
Issue
3
Pages
1727-1734
ISSN
  • 0937-4477 (ISSN-L)
  • 1434-4726
OpenAlex
W2518998053
Cited by
93
References
34
Citations by year
2026: 1 · 2025: 3 · 2024: 10 · 2023: 5 · 2022: 4 · 2021: 6 · 2020: 10 · 2019: 11 · 2018: 25 · 2017: 14 · 2016: 3
FWCI
14.21
Type
journal article
Language
en
Open access
closed
Locations
  • European Archives of Oto-Rhino-Laryngology (publishedVersion)
  • PubMed (publishedVersion)
  • mediaTUM – the media and publications repository of the Technical University Munich (Technical University Munich) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
upper airway stimulation, obstructive sleep apnea, apnea-hypopnea index, oxygen desaturation index, daytime sleepiness, medication adherence, adverse events, treatment outcomes
MeSH terms
Adult, Aged, Electric Stimulation Therapy, Female, Humans, Male, Middle Aged, Patient Compliance, Prospective Studies, Respiratory System, Treatment Outcome, Polysomnography, Sleep Apnea, Obstructive

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Selective upper airway stimulation for obstructive sleep apnea: a single center clinical experience. https://app.cochat.ai/papers/10.1007/s00405-016-4297-6
The paper
Heiser, C., Knopf, A., Bas, M., Gahleitner, C., & Hofauer, B. (2017). Selective upper airway stimulation for obstructive sleep apnea: a single center clinical experience. European Archives of Oto-Rhino-Laryngology. https://doi.org/10.1007/s00405-016-4297-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.