Quantifying fat replacement of muscle by quantitative MRI in muscular dystrophy
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The muscular dystrophies are rare orphan diseases, characterized by progressive muscle weakness: the most common and well known is Duchenne muscular dystrophy which affects young boys and progresses quickly during childhood. However, over 70 distinct variants have been identified to date, with different rates of progression, implications for morbidity, mortality, and quality of life. There are presently no curative therapies for these diseases, but a range of potential therapies are presently reaching the stage of multi-centre, multi-national first-in-man clinical trials. There is a need for sensitive, objective end-points to assess the efficacy of the proposed therapies. Present clinical measurements are often too dependent on patient effort or motivation, and lack sensitivity to small changes, or are invasive. Quantitative MRI to measure the fat replacement of skeletal muscle by either chemical shift imaging methods (Dixon or IDEAL) or spectroscopy has been demonstrated to provide such a sensitive, objective end-point in a number of studies. This review considers the importance of the outcome measures, discusses the considerations required to make robust measurements and appropriate quality assurance measures, and draws together the existing literature for cross-sectional and longitudinal cohort studies using these methods in muscular dystrophy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Emery, A. E. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07815-7 · Cited by 1,667
Cited by
Quantitative analysis of skeletal muscle by computed tomography imaging—State of the art
Engelke, K., Museyko, O., Wang, L., & Laredo, J.-D. (2018) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2018.10.004 · Cited by 248
Ahn, H., Kim, D. W., Ko, Y., Ha, J., Shin, Y. B., Lee, J., Sung, Y. S., & Kim, K. W. (2021) · Ageing Research Reviews · doi:10.1016/j.arr.2021.101398 · Cited by 218
MRI in the assessment of adipose tissues and muscle composition: how to use it
Huber, F. A., Del Grande, F., Rizzo, S., Guglielmi, G., & Guggenberger, R. (2020) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims.2020.02.06 · Cited by 102
Grimm, A., Nickel, M. D., Chaudry, O., Uder, M., Jakob, F., Kemmler, W., Quick, H. H., & Engelke, K. (2019) · European Journal of Radiology · doi:10.1016/j.ejrad.2019.03.019 · Cited by 16
Metadata
- Authors
- Burakiewicz, J., Sinclair, C. D. J., Fischer, D., Walter, G. A., Kan, H. E., & Hollingsworth, K. G.
- Venue
- Journal of Neurology
- Published
- 2017-07-01
- Volume
- 264
- Issue
- 10
- Pages
- 2053-2067
- ISSN
- 0012-1037 (ISSN-L)
- 0340-5354
- 1432-1459
- OpenAlex
- W2724098443
- Cited by
- 225
- References
- 1
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantifying fat replacement of muscle by quantitative MRI in muscular dystrophy. https://app.cochat.ai/papers/10.1007/s00415-017-8547-3
- The paper
- Burakiewicz, J., Sinclair, C. D. J., Fischer, D., Walter, G. A., Kan, H. E., & Hollingsworth, K. G. (2017). Quantifying fat replacement of muscle by quantitative MRI in muscular dystrophy. Journal of Neurology. https://doi.org/10.1007/s00415-017-8547-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.