Sub-retinal hemorrhage during internal limiting membrane peeling for a macular hole
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Purpose To report the occurrence of sub-retinal hemorrhage during peeling of the internal limiting membrane (ILM). Case reports In case 1, a three-port pars plana vitrectomy was performed on a 57-year-old woman with a macular hole. Following the staining of the ILM with indocyanine green, the ILM was peeled with forceps, and a sub-retinal and vitreous hemorrhage resulted from a vein during the peeling. The bleeding was stopped by elevating the intraocular pressure. The final visual acuity was 20/30. In case 2, similar procedures were performed on a 68-year-old woman with a macular hole. A sub-retinal hemorrhage occurred while peeling the ILM. The pre-operative visual acuity was 20/300, and final visual acuity was 20/200. Conclusions Surgeons should be aware that sub-retinal and vitreous hemorrhage can be a complication of ILM peeling.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This limitation can be overcome by incorporating force sensing elements along the distal portion of the instrument shaft, such that the active sensing part of the sensor is completely situated along the tool shaft inside the eye [26].”
From Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery (2012) · cites this paper as [26]
In the citing paper
“a hook tool with 3 integrated FBG sensors was manufactured following the design of Iordachita et al. as shown in Fig. 1 [26].”
From Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery (2012) · cites this paper as [26]
In the citing paper
“FBGs are robust optical sensors capable of detecting changes in strain. By measuring the bending of the tool they allow for calculation of the force in the transverse plane with a sensitivity of 0.25 mN.”
From Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery (2012) · cites this paper as [26]
Citations
Cites
Macular hole surgery with and without internal limiting membrane peeling
Brooks, H. L. (2000) · Ophthalmology · doi:10.1016/s0161-6420(00)00331-6 · Cited by 642
Macular hole surgery with internal-limiting membrane peeling and intravitreous air
Park, D. W., Sipperley, J. O., Sneed, S. R., Dugel, P. U., & Jacobsen, J. (1999) · Ophthalmology · doi:10.1016/s0161-6420(99)00730-7 · Cited by 414
Indocyanine green-assisted peeling of the internal limiting membrane may cause retinal damage
Gandorfer, A., Haritoglou, C., Gass, C. A., Ulbig, M. W., & Kampik, A. (2001) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(01)01087-x · Cited by 310
Da Mata, A. P., Burk, S. E., Riemann, C. D., Rosa, R. H., Snyder, M. E., Petersen, M. R., & Foster, R. E. (2001) · Ophthalmology · doi:10.1016/s0161-6420(01)00593-0 · Cited by 283
Macular changes after peeling of the internal limiting membrane in macular hole surgery
Haritoglou, C., Gass, C. A., Schaumberger, M., Ehrt, O., Gandorfer, A., & Kampik, A. (2001) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(01)01093-5 · Cited by 233
Indocyanine green selectively stains the internal limiting membrane
Gandorfer, A., Messmer, E. M., Ulbig, M. W., & Kampik, A. (2001) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00924-7 · Cited by 176
Cited by
Internal Limiting Membrane Peeling in Vitreo-retinal Surgery
Abdelkader, E., & Lois, N. (2008) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.04.006 · Cited by 111
Nam, K. Y., & Kim, J. (2014) · Retina · doi:10.1097/iae.0000000000000421 · Cited by 88
3-DOF Force-Sensing Motorized Micro-Forceps for Robot-Assisted Vitreoretinal Surgery
Gonenc, B., Chamani, A., Handa, J. T., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2694965 · Cited by 79
Preliminary evaluation of a micro-force sensing handheld robot for vitreoretinal surgery
Gonenc, B., Balicki, M. A., Handa, J., Gehlbach, P., Riviere, C. N., Taylor, R. H., & Iordachita, I. (2012) · 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems · doi:10.1109/iros.2012.6385715 · Cited by 54
Design of 3-DOF force sensing micro-forceps for robot assisted vitreoretinal surgery
Gonenc, B., Handa, J. T., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610841 · Cited by 34
A comparative study for robot assisted vitreoretinal surgery: Micron vs. the Steady-Hand Robot
Gonenc, B., Handa, J. T., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2013) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2013.6631266 · Cited by 32
Gonenc, B., Feldman, E., Gehlbach, P. L., Handa, J. T., Taylor, R. H., & Iordachita, I. I. (2014) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2014.6907035 · Cited by 33
Complications of Macular Peeling
Durán, M. A., Manzano-Muñoz, B., Vallejo-García, J. L., & García-Martínez, J. (2015) · Journal of Ophthalmology · doi:10.1155/2015/467814 · Cited by 32
FBG-based transverse and axial force-sensing micro-forceps for retinal microsurgery
Gonenc, B., & Iordachita, I. I. (2016) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2016.7808628 · Cited by 29
Uchida, A., Srivastava, S. K., & Ehlers, J. P. (2017) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.17-21584 · Cited by 29
Gonenc, B., Gehlbach, P. L., Handa, J. T., Taylor, R. H., & Iordachita, I. I. (2014) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2014.6913784 · Cited by 28
INDOCYANINE GREEN???ASSISTED INTERNAL LIMITING MEMBRANE PEELING FOR MACULAR HOLES
Mavrofrides, E. C., Smiddy, W. E., Kitchens, J. W., SALICONE, A., & Feuer, W. J. (2006) · Retina · doi:10.1097/01.iae.0000226602.34867.f9 · Cited by 27
An FBG-Based 3-DOF Force Sensor With Simplified Structure for Retinal Microsurgery
Zhang, H., Yi, H., Fan, Z., Pang, L., Bai, M., Wang, C., & Zhao, J. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3187771 · Cited by 22
Hybrid position/force control of an active handheld micromanipulator for membrane peeling
Wells, T. S., Yang, S., MacLachlan, R. A., Lobes, L. A., Martel, J. N., & Riviere, C. N. (2015) · International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.1659 · Cited by 21
Gao, A., Gonenc, B., Guo, J., Liu, H., Gehlbach, P. L., & Iordachita, I. I. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523674 · Cited by 20
Abushagur, A. A. G., Bakar, A. A. A., Zan, M. S. D., & Arsad, N. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2602239 · Cited by 17
Effects of micro-vibratory modulation during robot-assisted membrane peeling
Gonenc, B., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2015) · IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) · doi:10.1109/iros.2015.7353912 · Cited by 13
Sub-millinewton force sensor for Vitreoretinal microsurgery using linear chirp fiber Bragg grating
Abushagur, A. A. G., Bakar, A. A. A., Arsad, N., & Shaari, S. B. (2014) · IEEE International Conference on Photonics · doi:10.1109/icp.2014.7002305 · Cited by 10
A Robotic Microforceps for Retinal Microsurgery With Adaptive Clamping Method
Zhang, H., Yi, H., Wang, C., Yang, J., Jin, T., & Zhao, J. (2024) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2024.3378275 · Cited by 10
Single Scan OCT-Based Retina Detection for Robot-Assisted Retinal Vein Cannulation
Borghesan, G., Ourak, M., Lankenau, E. M., Hüttmann, G., Schulz‐Hildebrandt, H., Willekens, K., Stalmans, P., Reynaerts, D., & Poorten, E. V. (2018) · Journal of Medical Robotics Research · doi:10.1142/s2424905x18400056 · Cited by 9
Comparison of Surgical Times Between Manual and Robot-Assisted Epiretinal Membrane Peeling
Eberle, A., Turgut, F., Somfai, G. M., Saad, A., de Smet, M. D., Hasler, P. W., Heussen, F. M., & Becker, M. D. (2024) · Translational Vision Science & Technology · doi:10.1167/tvst.13.8.27 · Cited by 9
Safe tissue manipulation in retinal microsurgery via motorized instruments with force sensing
Gonenc, B., Gehlbach, P. L., Taylor, R. H., & Iordachita, I. I. (2017) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2017.8234070 · Cited by 8
Use Case for European Robotics in Ophthalmologic Micro-Surgery
Poorten, E. V., Esteveny, L., Gijbels, A., Rosa, B., Schoevaerdts, L., Willekens, K., Stalmans, P., Reynaerts, D., Naus, G. J. L., Beelen, M. J., et al. (2015) · Lirias · Cited by 5
Abushagur, A. A. G., Bakar, A. A. A., Zan, M. S. D., Arsad, N., & Shaari, S. B. (2015) · International Conference on Sensing Technology · doi:10.1109/icsenst.2015.7438410 · Cited by 2
Arshad, A., Saleem, M. M., Jabbar, H., Ali, M. U., Tiwana, M. I., & Cheung, R. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3494875 · Cited by 1
Choi, Y. J., Kim, S. W., Oh, I. K., Oh, J., & Huh, K. (2008) · Journal of the Korean Ophthalmological Society · doi:10.3341/jkos.2008.49.4.595
Pametni hirurški instrumenti kod minimalno invazivnih operativnih zahvata
Aličić, A., & Aličić, M. (2022) · Tehnika · doi:10.5937/tehnika2206714a
Borghesan, G., Ourak, M., Lankenau, E. M., Neffin, R., Koch, P., Schulz‐Hildebrandt, H., Willekens, K., Stalmans, P., Reynaerts, D., & Poorten, E. V. (2017) · Lirias
Deep dive into ilm in nontractional dme: why we should or should not remove it
Sembiring, S. B., Harley, O., Siregar, A. M. K., & Adriono, G. A. (2025) · Journal of Retina-Vitreous · doi:10.37845/ret.vit.2025.34.48
Adaptive Force Control for Time-Varying Parameter Systems in Film Peeling
Yi, H., Fan, Z., Qin, W., Zhang, H., & Zhao, J. (2026) · Eksploatacja i Niezawodnosc - Maintenance and Reliability · doi:10.17531/ein/220212
Metadata
- Authors
- Nakata, K., Ohji, M., Ikuno, Y., Kusaka, S., Gomi, F., & Tano, Y.
- Affiliations
- The University of Osaka (JP)
- Venue
- Graefe's Archive for Clinical and Experimental Ophthalmology
- Published
- 2003-05-09
- Volume
- 241
- Issue
- 7
- Pages
- 582-584
- ISSN
- 0721-832X (ISSN-L)
- 1435-702X
- OpenAlex
- W1979471043
- Cited by
- 28
- References
- 6
- Citations by year
- 2026: 1 · 2024: 3 · 2022: 2 · 2018: 1 · 2017: 3 · 2016: 3 · 2015: 5 · 2014: 4 · 2013: 2 · 2012: 1
- FWCI
- 0.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Graefe s Archive for Clinical and Experimental Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Retinal and Macular Surgery
- Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
- Health Sciences › Medicine › Ophthalmology › Retinopathy of Prematurity Studies
- Keywords
- subretinal hemorrhage, internal limiting membrane peeling, macular hole, vitrectomy complications, vitreous hemorrhage, indocyanine green staining, intraocular pressure elevation, pars plana vitrectomy
- MeSH terms
- Aged, Female, Humans, Intraoperative Complications, Middle Aged, Postoperative Period, Retinal Hemorrhage, Retinal Perforations, Visual Acuity, Vitrectomy, Epiretinal Membrane
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.