Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.

The parameters of the porcine eyeball

Sanchez, Irene, Martin, Raul, Ussa, Fernando, Fernandez-Bueno, Ivan · 2011 · Graefe's Archive for Clinical and Experimental Ophthalmology

Abstract

Background The eye of the domestic pig (Sus scrofa domestica) is an ex vivo animal model often used in vision sciences research (retina studies, glaucoma, cataracts, etc.). However, only a few papers have compiled pig eye anatomical descriptions. The purpose of this paper is to describe pig and human eye anatomical parameters to help investigators in their choice of animal model depending on their study objective.Methods A wide search of current medical literature was performed (English language) using PubMed. Anteroposterior axial length and corneal radius, astigmatism, vertical and horizontal diameter, and pachymetry (slit-scan and ultrasound) were measured in five enucleated pig eyes of animals 6 to 8 months old.Results Horizontal corneal diameter was 14.31 ± 0.25 mm (CI 95% 14.03 mm-14.59 mm), vertical diameter was 12.00 ± 0 mm, anteroposterior length was 23.9 ± 0.08 mm (CI 95% 23.01 mm-29.99 mm), central corneal ultrasound pachymetry was 877.6 ± 13.58 μm (CI 95% 865.70 μm-889.50 μm) and slit-scan pachymetry was 906.2 ± 15.30 μm (CI 95% 892.78 μm-919.61 μm). Automatic keratometry (main meridians) was 41.19 ± 1.76D and 38.83 ± 2.89D (CI 95% 40.53D-41.81D and 37.76D-39.89D respectively) with an astigmatism of 2.36 ± 1.70D (CI 95% 1.72D-3.00D), and manual keratometry was 41.05 ± 0.54D and 39.30 ± 1.15D (CI 95% 40.57D-41.52D and 38.29D-40.31D respectively) with an astigmatism of 1.75 ± 1.31D (CI 95% 0.60D-2.90D).Conclusion This paper describes the anatomy of the pig eyeball for easy use and interpretation by researchers who are considering their choice of animal model in vision sciences research.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00417-011-1617-9

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 39 references

Research works printed but not linked: 2

  1. Newell FW (1993) Oftalmología fundamentos y conceptos, 7th edn. Mosby, España
  2. Forrester J, Dick A, McMenamin P, Lee W (1996) The eye basics sciences in practice. Saunders, London

Cited by

See all 315

Metadata

Authors
Sanchez, I., Martin, R., Ussa, F., & Fernandez-Bueno, I.
Affiliations
Universidad de Valladolid (ES)
Venue
Graefe's Archive for Clinical and Experimental Ophthalmology
Published
2011-02-02
Volume
249
Issue
4
Pages
475-482
ISSN
  • 0721-832X (ISSN-L)
  • 1435-702X
OpenAlex
W2025624506
Cited by
298
References
39
Citations by year
2026: 11 · 2025: 37 · 2024: 22 · 2023: 33 · 2022: 27 · 2021: 23 · 2020: 22 · 2019: 24 · 2018: 19 · 2017: 18 · 2016: 9 · 2015: 18 · 2014: 12 · 2013: 13 · 2012: 5
FWCI
10.48
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Graefe s Archive for Clinical and Experimental Ophthalmology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
  • Health Sciences › Medicine › Ophthalmology › Ocular Disorders and Treatments
  • Health Sciences › Medicine › Ophthalmology › Corneal surgery and disorders
Keywords
axial length, corneal diameter, pachymetry, keratometry, astigmatism, enucleated eyes, corneal thickness, corneal curvature, ocular biometry, glaucoma, cataract, ultrasonic pachymetry
MeSH terms
Anatomy, Comparative, Animals, Eye, Humans, Corneal Topography, Models, Animal, Sus scrofa

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The parameters of the porcine eyeball. https://app.cochat.ai/papers/10.1007/s00417-011-1617-9
The paper
Sanchez, I., Martin, R., Ussa, F., & Fernandez-Bueno, I. (2011). The parameters of the porcine eyeball. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-011-1617-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.