Detecting glaucoma based on spectral domain optical coherence tomography imaging of peripapillary retinal nerve fiber layer: a comparison study between hand-crafted features and deep learning model
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Purpose To develop a deep learning (DL) model for automated detection of glaucoma and to compare diagnostic capability against hand-craft features (HCFs) based on spectral domain optical coherence tomography (SD-OCT) peripapillary retinal nerve fiber layer (pRNFL) images.Methods A DL model with pre-trained convolutional neural network (CNN) based was trained using a retrospective training set of 1501 pRNFL OCT images, which included 690 images from 153 glaucoma patients and 811 images from 394 normal subjects. The DL model was further tested in an independent test set of 50 images from 50 glaucoma patients and 52 images from 52 normal subjects. A customized software was used to extract and measure HCFs including pRNFL thickness in average and four different sectors. Area under the receiver operator characteristics (AROC) curves was calculated to compare the diagnostic capability between DL model and hand-crafted pRNFL parameters.Results In this study, the DL model achieved an AROC of 0.99 [CI: 0.97 to 1.00] which was significantly larger than the AROC values of all other HCFs (AROCs 0.661 with 95% CI 0.549 to 0.772 for temporal sector, AROCs 0.696 with 95% CI 0.549 to 0.799 for nasal sector, AROCs 0.913 with 95% CI 0.855 to 0.970 for superior sector, AROCs 0.938 with 95% CI 0.894 to 0.982 for inferior sector, and AROCs 0.895 with 95% CI 0.832 to 0.957 for average).Conclusion Our study demonstrated that DL models based on pre-trained CNN are capable of identifying glaucoma with high sensitivity and specificity based on SD-OCT pRNFL images.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Only eight studies14–21 used prospectively collected data”
From Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis (2021) · cites this paper as [20]
Citations
Cites
ImageNet Large Scale Visual Recognition Challenge
Russakovsky, O., Deng, J., Su, H., Krause, J., Satheesh, S., Ma, S., Huang, Z., Karpathy, A., Khosla, A., Bernstein, M., et al. (2015) · International Journal of Computer Vision · doi:10.1007/s11263-015-0816-y · Cited by 39,380
Rethinking the Inception Architecture for Computer Vision
Szegedy, C., Vanhoucke, V., Ioffe, S., Shlens, J., & Wojna, Z. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.308 · Cited by 32,138
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Learning Deep Features for Discriminative Localization
Zhou, B., Khosla, A., Lapedriza, A., Oliva, A., & Torralba, A. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.319 · Cited by 11,428 · cited 1×
“To visualize the most predictive features for detecting glaucomatous pRNFL changes, a class activation map (CAM) was used to open the “ black box ” of DL model [19].”
MethodGulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Wang, X., Peng, Y., Lu, L., Lu, Z., Bagheri, M., & Summers, R. M. (2017) · 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2017.369 · Cited by 4,616 · cited 1×
“Transfer learning has proven to be a highly effective technique and been widely used in multiple medical domains with limited data [7, 23].”
MethodThe Pathophysiology and Treatment of Glaucoma: A Review
Weinreb, R. N., Aung, T., & Medeiros, F. A. (2014) · JAMA · doi:10.1001/jama.2014.3192 · Cited by 4,210
Lakhani, P., & Sundaram, B. (2017) · Radiology · doi:10.1148/radiol.2017162326 · Cited by 1,775
Understanding Neural Networks Through Deep Visualization
Yosinski, J., Clune, J., Nguyen, A. M., Fuchs, T. J., & Lipson, H. (2015) · arXiv (Cornell University) · doi:10.48550/arxiv.1506.06579 · Cited by 1,358
Quigley, H. A. (2011) · The Lancet · doi:10.1016/s0140-6736(10)61423-7 · Cited by 1,121
Cited by
Transfer learning for medical image classification: a literature review
Kim, H. E., Cosa-Linan, A., Santhanam, N., Jannesari, M., Maros, M. E., & Ganslandt, T. (2022) · BMC Medical Imaging · doi:10.1186/s12880-022-00793-7 · Cited by 965
Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
Aggarwal, R., Sounderajah, V., Martin, G., Ting, D. S. W., Karthikesalingam, A., King, D., Ashrafian, H., & Darzi, A. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00438-z · Cited by 946
Digital technology, tele-medicine and artificial intelligence in ophthalmology: A global perspective
Li, J.-P. O., Liu, H., Ting, D. S. J., Jeon, S., Chan, R. V. P., Kim, J. E., Sim, D. A., Thomas, P. B. M., Lin, H., Chen, Y., et al. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100900 · Cited by 626
“…practice is expected to revolu-tionise the current disease management process, improve early detection and there are hopes that it will ultimately improve outcomes (Balyen and Peto, 2019; Tan et al., 2019), although the cost-effectiveness of these systems remain unclear (Xie et al., 2020).”
InfluentialArtificial intelligence in glaucoma: opportunities, challenges, and future directions
Huang, X., Islam, M. R., Prome, S. A., Ahmed, F., Kazami, E., Serhan, H. A. A., Abd-Alrazaq, A. A., & Yousefi, S. (2023) · BioMedical Engineering OnLine · doi:10.1186/s12938-023-01187-8 · Cited by 83
Applications of deep learning in detection of glaucoma: A systematic review
Mirzania, D., Thompson, A. C., & Muir, K. W. (2020) · European Journal of Ophthalmology · doi:10.1177/1120672120977346 · Cited by 79
“Overall, the majority of studies focused on differentiation of glaucoma from non-glaucoma, 92,100,102 while the study by Thompson et al. 93 tested their DL algorithm across different levels of disease severity.”
BackgroundLing, X. C., Chen, H. S.-L., Yeh, P., Cheng, Y.-C., Huang, C.-Y., Shen, S., & Lee, Y. (2025) · Biomedicines · doi:10.3390/biomedicines13020420 · Cited by 85
“…forest plots and sROC curves for both internal (black) and external (red) photography, the externally tested performance of the AI algorithm using OCT for glaucoma diagnosis has lower overall accuracy compared to the internal testing, as shown in Figure 5. imaging [20,32,34–36 ,47,48,54,56,57,60].”
Dolar-Szczasny, J., Barańska, A., & Ręjdak, R. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12093161 · Cited by 72
“In a recent investigation, another DL model was developed utilizing spectral domain OCT images to automatize glaucoma detection [88].”
MethodWu, J., Nishida, T., Weinreb, R. N., & Lin, J. (2021) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2021.12.008 · Cited by 60
Diagnostic Accuracy of Artificial Intelligence in Glaucoma Screening and Clinical Practice
Chaurasia, A. K., Greatbatch, C. J., & Hewitt, A. W. (2022) · Journal of Glaucoma · doi:10.1097/ijg.0000000000002015 · Cited by 54
Deep Learning–Assisted Detection of Glaucoma Progression in Spectral-Domain OCT
Mariottoni, E. B., Datta, S., Shigueoka, L., Jammal, A. A., Tavares, I. M., Henao, R., Carin, L., & Medeiros, F. A. (2022) · Ophthalmology Glaucoma · doi:10.1016/j.ogla.2022.11.004 · Cited by 51
The AI revolution in glaucoma: Bridging challenges with opportunities
Li, F., Wang, D., Yang, Z., Zhang, Y., Jiang, J., Liu, X., Kong, K., Zhou, F., Tham, C. C. Y., Medeiros, F. A., et al. (2024) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2024.101291 · Cited by 49
Artificial Intelligence and Advanced Technology in Glaucoma: A Review
Tonti, E., Tonti, S., Mancini, F., Bonini, C., Spadea, L., D’Esposito, F., Gagliano, C., Musa, M., & Zeppieri, M. (2024) · Journal of Personalized Medicine · doi:10.3390/jpm14101062 · Cited by 55
“The limitations of current studies on OCT and AI mainly involve segmentation errors, the limited ethnic diversity in the datasets, and the exclusion of cases of secondary glaucoma or angle-closure glaucoma [64–67].”
BackgroundBuisson, M., Navel, V., Labbé, A., Watson, S. L., Baker, J. S., Murtagh, P. J., Chiambaretta, F., & Dutheil, F. (2021) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.14000 · Cited by 31
Shi, N., Liu, G., & Cao, M.-F. (2024) · International Journal of Ophthalmology · doi:10.18240/ijo.2024.03.02 · Cited by 30
Telehealth and Screening Strategies in the Diagnosis and Management of Glaucoma
Wong, S. H., & Tsai, J. C. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10163452 · Cited by 18
Thompson, A. C., Falconi, A., & Sappington, R. M. (2022) · Frontiers in Ophthalmology · doi:10.3389/fopht.2022.937205 · Cited by 17
Yuen, J., Pike, S., Khachikyan, S., & Nallasamy, S. (2022) · Exon Publications eBooks · doi:10.36255/exon-publications-digital-health-telehealth-ophthalmology · Cited by 23
“99, respectively, with some models having a higher sensitivity in detecting early glaucoma than with standard OCT and VF (47-49).”
BackgroundZheng, C., Koh, V., Bian, F., Luo, L., Xie, X., Wang, Z., Yang, J., Chew, P., & Zhang, M. (2021) · Annals of Translational Medicine · doi:10.21037/atm-20-7436 · Cited by 16
Self-citationKako, N. A., & Abdulazeez, A. M. (2022) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/1573405618666220308112732 · Cited by 18
Peng, J., Xie, X., Lu, Z., Xu, Y., Xie, M., Luo, L., Xiao, H., Ye, H., Chen, L., Yang, J., et al. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1424749 · Cited by 12
Self-citationHao, L., Hu, Y., Xu, Y., Fu, H., Miao, H., Zheng, C., & Liu, J. (2022) · Eye and Vision · doi:10.1186/s40662-022-00314-1 · Cited by 12
“In the current study, we defined the normal visual field as follows: a mean deviation (MD) and pattern standard deviation (PSD) within 95% confidence limits and a glaucoma hemifield test (GHT) result within normal limits [25].”
BackgroundSelf-citationApplication of artificial intelligence in glaucoma care: An updated review
Wu, J., Lin, S. C., & Moghimi, S. (2024) · Taiwan Journal of Ophthalmology · doi:10.4103/tjo.tjo-d-24-00044 · Cited by 12
Sadikan, M. Z., Nasir, N. A. A., Ghani, N. A. A., Lambuk, L., Iezhitsa, I. N., & Agarwal, A. R. (2021) · Asian Journal of Medicine and Biomedicine · doi:10.37231/ajmb.2021.5.1.422 · Cited by 8
“based on existing works [6, 21, 22, 23] and is a cheaper”
MethodRetinal nerve fibre layer thickness and choroidal thickness: An evaluation in psoriasis patients
Aksoy, M., Toptan, M., & An, İ. (2020) · International Journal of Clinical Practice · doi:10.1111/ijcp.13904 · Cited by 6
Xie, X., Chen, B., Yang, J., Huang, C., Qiu, K., Zheng, C., & Zhang, M. (2021) · Scientific Reports · doi:10.1038/s41598-021-88604-x · Cited by 5
Self-citationScreening Strategies and Methodologies
Founti, P., Stuart, K. V., Nolan, W. P., Khawaja, A. P., & Foster, P. J. (2024) · Journal of Glaucoma · doi:10.1097/ijg.0000000000002426 · Cited by 8
“47 50 In addition, AI algorithms trained on structural 51 – 56 and functional 57 – 60 test modalities have shown impressive performance, comparable or better than humans, 53,60 in discriminating between potentially glaucomatous and non-glaucomatous eyes.”
Vision-based Human Detection by Fine-Tuned SSD Models
Cheng, T. J., Nasir, A. F. A., Majeed, A. P. P. A., Razman, M. A. M., & Lim, T. L. (2022) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2022.0131143 · Cited by 3
“To ensure the fine-tuning of the object detection models are neither underfitting nor overfitting, the learning behaviour of the models were monitored throughout the fine-tuning process via the training and validation loss graph [24], [25].”
MethodCavanela, C. R., & López-Alegría, F. (2023) · Revista Mexicana de Oftalmología · doi:10.5005/rmo-11013-0040 · Cited by 3
Chiang, C. Y. N., Miléa, D., & Girard, M. J. A. (2025) · Springer eBooks · doi:10.1007/978-3-031-72156-4_26 · Cited by 3
Cavanela, C. R., & López-Alegría, F. (2023) · Revista Mexicana de Oftalmología · doi:10.5005/rmo-11013-0044
“Zheng et al, 2019 20 China 50 glaucomatous patients with an average age of 50.7 years, 42 of whom were male.”
InfluentialInnovations in glaucoma diagnostics
Szewczuk, A., & Zaleska-Żmijewska, A. (2023) · Klinika Oczna · doi:10.5114/ko.2023.133452
Antara, I. G. F. B., Winata, I. M. P. A., Dewi, P. E., Sari, N. P. E. F., Ariana, K. T. A., & Widhiada, I. W. (2024) · AIP conference proceedings · doi:10.1063/5.0199793
Additional file 3 of Transfer learning for medical image classification: a literature review
Kim, H. E., Cosa‐Linan, A., Santhanam, N., Jannesari, M., Maros, M. E., & Ganslandt, T. (2022) · Figshare · doi:10.6084/m9.figshare.19593962
Hao, L., Hu, Y., Xu, Y., Fu, H., Miao, H., Zheng, C., & Liu, J. (2022) · Figshare · doi:10.6084/m9.figshare.21506786
Self-citationAdditional file 1 of Transfer learning for medical image classification: a literature review
Kim, H. E., Cosa‐Linan, A., Santhanam, N., Jannesari, M., Maros, M. E., & Ganslandt, T. (2022) · Figshare · doi:10.6084/m9.figshare.19593956
Additional file 2 of Transfer learning for medical image classification: a literature review
Kim, H. E., Cosa‐Linan, A., Santhanam, N., Jannesari, M., Maros, M. E., & Ganslandt, T. (2022) · Figshare · doi:10.6084/m9.figshare.19593959
Advancing Teleophthalmology and Remote Monitoring Using Artificial Intelligence
Espaillat, A. (2026) · Springer eBooks · doi:10.1007/978-3-032-19336-0_22
Diabetic Retinopathy Classification from OCT Images using CNNs and Hybrid Multifractal Architectures
Dadiyala, C., Welekar, R. R., Jaiswal, A., Pande, A., & Ainchwar, O. (2026) · IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET) · doi:10.1109/sefet69291.2026.11687016
“Comparative investigations that compare features attained from deep learning approaches with traditional handcrafted features have revealed that CNN features were superior to their handcrafted counterpart in detecting retinal diseases [17].”
Metadata
- Authors
- Zheng, C., Xie, X., Huang, L., Chen, B., Yang, J., Lu, J., Qiao, T., Fan, Z., & Zhang, M.
- Affiliations
- Chinese University of Hong Kong (HK)
- Shantou University (CN)
- Shanghai Jiao Tong University (CN)
- Corresponding author
- Zhang, Mingzhi
- Venue
- Graefe's Archive for Clinical and Experimental Ophthalmology
- Published
- 2019-12-07
- Volume
- 258
- Issue
- 3
- Pages
- 577-585
- ISSN
- 0721-832X (ISSN-L)
- 1435-702X
- OpenAlex
- W2993661103
- Cited by
- 40
- References
- 27
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 8 · 2023: 5 · 2022: 12 · 2021: 8 · 2020: 3
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Graefe s Archive for Clinical and Experimental Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (81371010)
- Clinical Research Funds of Shantou University Medical College (20130101)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
- Keywords
- glaucoma detection, peripapillary retinal nerve fiber layer, spectral-domain optical coherence tomography, deep learning, convolutional neural networks, handcrafted features, automated diagnosis, pre-trained convolutional neural networks
- MeSH terms
- Deep Learning, Adolescent, Adult, Aged, Aged, 80 and over, Female, Glaucoma, Humans, Intraocular Pressure, Male, Middle Aged, Nerve Fibers, Optic Disk, Prospective Studies, Retinal Ganglion Cells, Visual Fields, Tomography, Optical Coherence, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.