Optimising high-intensity treadmill training using the running speed at maximal O2 uptake and the time for which this can be maintained
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The aim of this study was to compare the effects of two high-intensity, treadmill interval-training programs on 3000-m and 5000-m running performance. Maximal oxygen uptake (V̇O2max), the running speed associated with V̇O2max (vV̇O2max), the time for which vV̇O2max can be maintained (Tmax), running economy (RE), ventilatory threshold (VT) and 3000-m and 5000-m running times were determined in 27 well-trained runners. Subjects were then randomly assigned to three groups; (1) 60% Tmax, (2) 70% Tmax and (3) control. Subjects in the control group continued their normal training and subjects in the two Tmax groups undertook a 4-week treadmill interval-training program with the intensity set at vV̇O2max and the interval duration at the assigned Tmax. These subjects completed two interval-training sessions per week (60% Tmax=six intervals/session, 70% Tmax group=five intervals/session). Subjects were re-tested on all parameters at the completion of the training program. There was a significant improvement between pre- and post-training values in 3000-m time trial (TT) performance in the 60% Tmax group compared to the 70% Tmax and control groups [mean (SE); 60% Tmax=17.6 (3.5) s, 70% Tmax =6.3 (4.2) s, control=0.5 (7.7) s]. There was no significant effect of the training program on 5000-m TT performance [60% Tmax=25.8 (13.8) s, 70% Tmax=3.7 (11.6) s, control=9.9 (13.1) s]. Although there were no significant improvements in V̇O2max, vV̇O2max and RE between groups, changes in V̇O2max and RE were significantly correlated with the improvement in the 3000-m TT. Furthermore, VT and Tmax were significantly higher in the 60% Tmax group post- compared to pre-training. In conclusion, 3000-m running performance can be significantly improved in a group of well-trained runners, using a 4-week treadmill interval training program at vV̇O2max with interval durations of 60% Tmax.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Billat, V. L., Slawinski, J., Bocquet, V., Demarle, A., Lafitte, L., Chassaing, P., & Koralsztein, J.-P. (2000) · European Journal of Applied Physiology · doi:10.1007/s004210050029 · Cited by 221 · cited 3×
“V O2max for 10 min or 83% of total running time ( Billat et al. 2000 ).”
Background
Cited by
Buchheit, M., & Laursen, P. B. (2013) · Sports Medicine · doi:10.1007/s40279-013-0029-x · Cited by 1,490
Buchheit, M., & Laursen, P. B. (2013) · Sports Medicine · doi:10.1007/s40279-013-0066-5 · Cited by 869
Training for intense exercise performance: high‐intensity or high‐volume training?
Laursen, P. B. (2010) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2010.01184.x · Cited by 444
Midgley, A. W., McNaughton, L. R., & Jones, A. M. (2007) · Sports Medicine · doi:10.2165/00007256-200737100-00003 · Cited by 319
Midgley, A. W., McNaughton, L. R., & Wilkinson, M. (2006) · Sports Medicine · doi:10.2165/00007256-200636020-00003 · Cited by 283
Metadata
- Authors
- Smith, T. P., Coombes, J. S., & Geraghty, D. P.
- Venue
- European Journal of Applied Physiology
- Published
- 2003-05
- Volume
- 89
- Issue
- 3
- Pages
- 337-343
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- OpenAlex
- W1988965630
- Cited by
- 120
- References
- 1
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimising high-intensity treadmill training using the running speed at maximal O2 uptake and the time for which this can be maintained. https://app.cochat.ai/papers/10.1007/s00421-003-0806-6
- The paper
- Smith, T. P., Coombes, J. S., & Geraghty, D. P. (2003). Optimising high-intensity treadmill training using the running speed at maximal O2 uptake and the time for which this can be maintained. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-003-0806-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.