Objective evaluation of laparoscopic surgical skills in wet lab training based on motion analysis and machine learning
Open accessAbstract
Background: Our aim was to build a skill assessment system, providing objective feedback to trainees based on the motion metrics of laparoscopic surgical instruments. Methods: Participants performed tissue dissection around the aorta (tissue dissection task) and renal parenchymal closure (parenchymal-suturing task), using swine organs in a box trainer under a motion capture (Mocap) system. Two experts assessed the recorded movies, according to the formula of global operative assessment of laparoscopic skills (GOALS: score range, 5–25), and the mean scores were utilized as objective variables in the regression analyses. The correlations between mean GOALS scores and Mocap metrics were evaluated, and potential Mocap metrics with a Spearman’s rank correlation coefficient value exceeding 0.4 were selected for each GOALS item estimation. Four regression algorithms, support vector regression (SVR), principal component analysis (PCA)-SVR, ridge regression, and partial least squares regression, were utilized for automatic GOALS estimation. Model validation was conducted by nested and repeated k-fold cross validation, and the mean absolute error (MAE) was calculated to evaluate the accuracy of each regression model. Results: Forty-five urologic, 9 gastroenterological, and 3 gynecologic surgeons, 4 junior residents, and 9 medical students participated in the training. In both tasks, a positive correlation was observed between the speed-related parameters (e.g., velocity, velocity range, acceleration, jerk) and mean GOALS scores, with a negative correlation between the efficiency-related parameters (e.g., task time, path length, number of opening/closing operations) and mean GOALS scores. Among the 4 algorithms, SVR showed the highest accuracy in the tissue dissection task ( $${\mathrm{MAE}}_{\mathrm{median}}=2.2352$$ MAE median = 2.2352 ), and PCA-SVR in the parenchymal-suturing task ( $${\mathrm{MAE}}_{\mathrm{median}}=1.2714$$ MAE median = 1.2714 ), based on 100 iterations of the validation process of automatic GOALS estimation. Conclusion: We developed a machine learning–based GOALS scoring system in wet lab training, with an error of approximately 1–2 points for the total score, and motion metrics that were explainable to trainees. Our future challenges are the further improvement of onsite GOALS feedback, exploring the educational benefit of our model and building an efficient training program.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In surgery and surgical subspecialties, AI has been used to learn and practice knot tying and laparoscopy training based on motion analysis and machine learning (ML); AI can enhance VR for medical skills training; one study reported unintended outcomes with both positive and negative consequences for learner competency in surgical skills, suggesting that intervention from human tutors may be
“In surgery and surgical subspecialties [86], it has been used to learn and practice knot tying [87] and laparoscopy training based on motion analysis and machine learning (ML) [88]. AI can enhance VR for medical skills training [89]. One study reported unintended outcomes with both positive and negative consequences for learner competency in surgical skills, suggesting that intervention from human”
From Artificial intelligence in undergraduate medical education: an updated scoping review (2025) · cites this paper as [88]
Split into 2 atoms — 1 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 1 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 12 · Cited by 38
- Authors
- Ebina, K., Abe, T., Hotta, K., Higuchi, M., Furumido, J., Iwahara, N., Kon, M., Miyaji, K., Shibuya, S., Lingbo, Y., Komizunai, S., Kurashima, Y., Kikuchi, H., Matsumoto, R., Osawa, T., Murai, S., Tsujita, T., Sase, K., Chen, X., Konno, A., & Shinohara, N.
- Affiliations
- Hokkaido University (JP)
- National Defense Academy of Japan (JP)
- Tohoku Gakuin University (JP)
- Hirosaki University (JP)
- Corresponding author
- Abe, Takashige
- ORCID
- Venue
- Langenbeck's Archives of Surgery
- Published
- 2022-04-08
- Volume
- 407
- Issue
- 5
- Pages
- 2123-2132
- ISSN
- 0023-8236 (ISSN-L)
- 1435-2451
- PMC
- PMC9399206
- OpenAlex
- W4225567947
- Cited by
- 38
- References
- 12
- Citations by year
- 2026: 8 · 2025: 14 · 2024: 11 · 2023: 3 · 2022: 2
- FWCI
- 7.16
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Langenbeck s Archives of Surgery (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Hokkaido University Collection of Scholarly and Academic Papers (Hokkaido University) (submittedVersion)
- Institutional Repositories DataBase (IRDB) (submittedVersion)
- Funders
- keirin (2018M-156)
- jsps grant-in-aid for scientific research (JP18H04102, JP17K08897, JP21H00893)
- Topics
- Health Sciences › Medicine › Surgery › Surgical Simulation and Training
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Innovations in Medical Education
- Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
- Keywords
- skill assessment, motion capture, wet lab training, tissue dissection, support vector regression, automatic scoring
- MeSH terms
- Simulation Training, Machine Learning, Animals, Clinical Competence, Female, Humans, Internship and Residency, Laparoscopy, Swine, Surgeons
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review