Cited by 38Surgical Simulation and TrainingInnovations in Medical EducationAnatomy and Medical Technology

Objective evaluation of laparoscopic surgical skills in wet lab training based on motion analysis and machine learning

Open access
Ebina, Koki, Abe, Takashige, Hotta, Kiyohiko, Higuchi, Madoka, Furumido, Jun, Iwahara, Naoya, Kon, Masafumi, Miyaji, Kou +13 more·2022·Langenbeck's Archives of Surgery

Abstract

Background: Our aim was to build a skill assessment system, providing objective feedback to trainees based on the motion metrics of laparoscopic surgical instruments. Methods: Participants performed tissue dissection around the aorta (tissue dissection task) and renal parenchymal closure (parenchymal-suturing task), using swine organs in a box trainer under a motion capture (Mocap) system. Two experts assessed the recorded movies, according to the formula of global operative assessment of laparoscopic skills (GOALS: score range, 5–25), and the mean scores were utilized as objective variables in the regression analyses. The correlations between mean GOALS scores and Mocap metrics were evaluated, and potential Mocap metrics with a Spearman’s rank correlation coefficient value exceeding 0.4 were selected for each GOALS item estimation. Four regression algorithms, support vector regression (SVR), principal component analysis (PCA)-SVR, ridge regression, and partial least squares regression, were utilized for automatic GOALS estimation. Model validation was conducted by nested and repeated k-fold cross validation, and the mean absolute error (MAE) was calculated to evaluate the accuracy of each regression model. Results: Forty-five urologic, 9 gastroenterological, and 3 gynecologic surgeons, 4 junior residents, and 9 medical students participated in the training. In both tasks, a positive correlation was observed between the speed-related parameters (e.g., velocity, velocity range, acceleration, jerk) and mean GOALS scores, with a negative correlation between the efficiency-related parameters (e.g., task time, path length, number of opening/closing operations) and mean GOALS scores. Among the 4 algorithms, SVR showed the highest accuracy in the tissue dissection task ( $${\mathrm{MAE}}_{\mathrm{median}}=2.2352$$ MAE median = 2.2352 ), and PCA-SVR in the parenchymal-suturing task ( $${\mathrm{MAE}}_{\mathrm{median}}=1.2714$$ MAE median = 1.2714 ), based on 100 iterations of the validation process of automatic GOALS estimation. Conclusion: We developed a machine learning–based GOALS scoring system in wet lab training, with an error of approximately 1–2 points for the total score, and motion metrics that were explainable to trainees. Our future challenges are the further improvement of onsite GOALS feedback, exploring the educational benefit of our model and building an efficient training program.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00423-022-02505-9

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In surgery and surgical subspecialties, AI has been used to learn and practice knot tying and laparoscopy training based on motion analysis and machine learning (ML); AI can enhance VR for medical skills training; one study reported unintended outcomes with both positive and negative consequences for learner competency in surgical skills, suggesting that intervention from human tutors may be

    “In surgery and surgical subspecialties [86], it has been used to learn and practice knot tying [87] and laparoscopy training based on motion analysis and machine learning (ML) [88]. AI can enhance VR for medical skills training [89]. One study reported unintended outcomes with both positive and negative consequences for learner competency in surgical skills, suggesting that intervention from human”

    From Artificial intelligence in undergraduate medical education: an updated scoping review (2025) · cites this paper as [88]

    Split into 2 atoms — 1 confirmed, 0 partially supported, 0 disputed, 0 misattributed, 1 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 12 · Cited by 38

Authors
Ebina, K., Abe, T., Hotta, K., Higuchi, M., Furumido, J., Iwahara, N., Kon, M., Miyaji, K., Shibuya, S., Lingbo, Y., Komizunai, S., Kurashima, Y., Kikuchi, H., Matsumoto, R., Osawa, T., Murai, S., Tsujita, T., Sase, K., Chen, X., Konno, A., & Shinohara, N.
Affiliations
  • Hokkaido University (JP)
  • National Defense Academy of Japan (JP)
  • Tohoku Gakuin University (JP)
  • Hirosaki University (JP)
Corresponding author
Abe, Takashige
Venue
Langenbeck's Archives of Surgery
Published
2022-04-08
Volume
407
Issue
5
Pages
2123-2132
ISSN
  • 0023-8236 (ISSN-L)
  • 1435-2451
OpenAlex
W4225567947
Cited by
38
References
12
Citations by year
2026: 8 · 2025: 14 · 2024: 11 · 2023: 3 · 2022: 2
FWCI
7.16
Type
journal article
Language
en
Open access
Locations
  • Langenbeck s Archives of Surgery (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Hokkaido University Collection of Scholarly and Academic Papers (Hokkaido University) (submittedVersion)
  • Institutional Repositories DataBase (IRDB) (submittedVersion)
Funders
  • keirin (2018M-156)
  • jsps grant-in-aid for scientific research (JP18H04102, JP17K08897, JP21H00893)
Topics
  • Health Sciences › Medicine › Surgery › Surgical Simulation and Training
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Innovations in Medical Education
  • Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
Keywords
skill assessment, motion capture, wet lab training, tissue dissection, support vector regression, automatic scoring
MeSH terms
Simulation Training, Machine Learning, Animals, Clinical Competence, Female, Humans, Internship and Residency, Laparoscopy, Swine, Surgeons

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review