CoChat

Comparability of automated human induced pluripotent stem cell culture: a pilot study

Open access
Archibald, Peter R. T., Chandra, Amit, Thomas, Dave, Chose, Olivier, Massouridès, Emmanuelle, Laâbi, Yacine, Williams, David J. · 2016 · Bioprocess and Biosystems Engineering
Cited by 30

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Consistent and robust manufacturing is essential for the translation of cell therapies, and the utilisation automation throughout the manufacturing process may allow for improvements in quality control, scalability, reproducibility and economics of the process. The aim of this study was to measure and establish the comparability between alternative process steps for the culture of hiPSCs. Consequently, the effects of manual centrifugation and automated non-centrifugation process steps, performed using TAP Biosystems' CompacT SelecT automated cell culture platform, upon the culture of a human induced pluripotent stem cell (hiPSC) line (VAX001024c07) were compared. This study, has demonstrated that comparable morphologies and cell diameters were observed in hiPSCs cultured using either manual or automated process steps. However, non-centrifugation hiPSC populations exhibited greater cell yields, greater aggregate rates, increased pluripotency marker expression, and decreased differentiation marker expression compared to centrifugation hiPSCs. A trend for decreased variability in cell yield was also observed after the utilisation of the automated process step. This study also highlights the detrimental effect of the cryopreservation and thawing processes upon the growth and characteristics of hiPSC cultures, and demonstrates that automated hiPSC manufacturing protocols can be successfully transferred between independent laboratories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00449-016-1659-9

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • A ROCK inhibitor permits survival of dissociated human embryonic stem cells

    Watanabe, K., Ueno, M., Kamiya, D., Nishiyama, A., Matsumura, M., Wataya, T., Takahashi, J. B., Nishikawa, S., Nishikawa, S.-I., Muguruma, K., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1310 · Cited by 2,055 · cited 1×

    “Rho-associated protein kinase (ROCK) inhibitor has been shown to allow for the survival and maintenance of pluripotency of pluripotent stem cells after dissociation [11], as well as improved viable hiPSC recovery after cryopreservation [12, 13].”
    Background
  • Generation of human induced pluripotent stem cells from dermal fibroblasts

    Lowry, W. E., Richter, L., Yachechko, R., Pyle, A. D., Tchieu, J., Sridharan, R., Clark, A. T., & Plath, K. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711983105 · Cited by 1,041 · cited 6×

    “Briefly, after fixation, the cells were added to flow cytometry tubes (BD Biosciences) containing either; one of the FITC SSEA-1, PE SSEA-3 and Alexa Fluor 647 TRA1-81 antibodies, or one of the FITC, PE and Alexa Fluor 647 isotype controls.”
    BackgroundInfluential
  • Why tissue engineering needs process engineering

    Archer, R., & Williams, D. J. (2005) · Nature Biotechnology · doi:10.1038/nbt1105-1353 · Cited by 101 · cited 1×

    “The automation of cell culture holds significant promise for the improvement of quality control, scalability, reproducibility and economics of the process [2, 3].”
    BackgroundSelf-citation

Cited by

See all 30

Metadata

Authors
Archibald, P. R. T., Chandra, A., Thomas, D., Chose, O., Massouridès, E., Laâbi, Y., & Williams, D. J.
Venue
Bioprocess and Biosystems Engineering
Published
2016-08-08
Volume
39
Issue
12
Pages
1847-1858
ISSN
  • 1615-7591 (ISSN-L)
  • 1615-7605
OpenAlex
W2491383018
Cited by
30
References
3
FWCI
1.35
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.