Raman spectroscopic based chemometric models to support a dynamic capacitance based cell culture feeding strategy
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Multiple process analytical technology (PAT) tools are now being applied in tandem for cell culture. Research presented used two in-line probes, capacitance for a dynamic feeding strategy and Raman spectroscopy for real-time monitoring. Data collected from eight batches at the 15,000 L scale were used to develop process models. Raman spectroscopic data were modelled using Partial Least Squares (PLS) by two methods-(1) use of the full dataset and (2) split the dataset based on the capacitance feeding strategy. Root mean square error of prediction (RMSEP) for the first model method of capacitance was 1.54 pf/cm and the second modelling method was 1.40 pf/cm. The second Raman method demonstrated results within expected process limits for capacitance and a 0.01% difference in total nutrient feed compared to the capacitance probe. Additional variables modelled using Raman spectroscopy were viable cell density (VCD), viability, average cell diameter, and viable cell volume (VCV).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The model complexity was reduced by incorporating off-line parameter data.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [77]
In the citing paper
“they found that full-scale pH was too complex to model”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [77]
In the citing paper
“This approach slightly improved the model predictions, but there were prediction errors that were not consistent between the two cell lines.”
From The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing (2022) · cites this paper as [77]
Citations
Cites
PLS-regression: a basic tool of chemometrics
Wold, S., Sjöström, M., & Eriksson, L. (2001) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(01)00155-1 · Cited by 10,084
Multi- and megavariate data analysis
Eriksson, L. (2006) · Cited by 736
Abu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322
Gagnon, M., Hiller, G., Luan, Y., Kittredge, A., DeFelice, J., & Drapeau, D. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23072 · Cited by 181
Craven, S., Whelan, J., & Glennon, B. (2014) · Journal of Process Control · doi:10.1016/j.jprocont.2014.02.007 · Cited by 171
Whelan, J., Craven, S., & Glennon, B. (2012) · Biotechnology Progress · doi:10.1002/btpr.1590 · Cited by 159
Berry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142
Berry, B. N., Dobrowsky, T. M., Timson, R. C., Kshirsagar, R., Ryll, T., & Wiltberger, K. (2016) · Biotechnology Progress · doi:10.1002/btpr.2205 · Cited by 135
Process control in cell culture technology using dielectric spectroscopy
Justice, C., Brix, A., Freimark, D., Kraume, M., Pfromm, P. H., Eichenmueller, B., & Czermak, P. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.03.002 · Cited by 133
On‐line biomass monitoring of CHO perfusion culture with scanning dielectric spectroscopy
Cannizzaro, C., Gügerli, R., Marison, I., & von Stockar, U. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10809 · Cited by 130
Cited by
The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
Bioprocess systems analysis, modeling, estimation, and control
Luo, Y., Kurian, V., & Ogunnaike, B. A. (2021) · Current Opinion in Chemical Engineering · doi:10.1016/j.coche.2021.100705 · Cited by 81
Applications of bio-capacitance to cell culture manufacturing
Bergin, A., Carvell, J. P., & Butler, M. (2022) · Biotechnology Advances · doi:10.1016/j.biotechadv.2022.108048 · Cited by 60
Shen, D., He, X., Weng, P., Liu, Y., & Wu, Z. (2022) · FEMS Yeast Research · doi:10.1093/femsyr/foac050 · Cited by 57
Advances in bioreactor control for production of biotherapeutic products
Nikita, S., Mishra, S., Gupta, K., Runkana, V., Gomes, J., & Rathore, A. S. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28346 · Cited by 52
Metadata
- Authors
- Rafferty, C., O’Mahony, J., Rea, R., Burgoyne, B., Balss, K. M., Lyngberg, O., O’Mahony-Hartnett, C., Hill, D., & Schaefer, E.
- Affiliations
- Munster Technological University (IE)
- Janssen (Ireland) (IE)
- Biogen (United States) (US)
- Corresponding author
- Rafferty, Carl
- Venue
- Bioprocess and Biosystems Engineering
- Published
- 2020-04-18
- Volume
- 43
- Issue
- 8
- Pages
- 1415-1429
- ISSN
- 1615-7591 (ISSN-L)
- 1615-7605
- OpenAlex
- W3017332122
- Cited by
- 21
- References
- 30
- Citations by year
- 2026: 1 · 2025: 4 · 2024: 6 · 2023: 3 · 2022: 2 · 2021: 4
- FWCI
- 1.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
- Locations
- Bioprocess and Biosystems Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Irish Research Council (EPSPG/2015/150)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Fluid Dynamics and Mixing
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Keywords
- Raman spectroscopy, capacitance probe, process analytical technology, partial least squares, chemometric models, real-time monitoring, viable cell density, cell viability, cell diameter, bioreactor scale-up
- MeSH terms
- Models, Biological, Spectrum Analysis, Raman, Batch Cell Culture Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Raman spectroscopic based chemometric models to support a dynamic capacitance based cell culture feeding strategy. https://app.cochat.ai/papers/10.1007/s00449-020-02336-2
- The paper
- Rafferty, C., O’Mahony, J., Rea, R., Burgoyne, B., Balss, K. M., Lyngberg, O., O’Mahony-Hartnett, C., Hill, D., & Schaefer, E. (2020). Raman spectroscopic based chemometric models to support a dynamic capacitance based cell culture feeding strategy. Bioprocess and Biosystems Engineering. https://doi.org/10.1007/s00449-020-02336-2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.