Transrectal quantitative shear wave elastography in the detection and characterisation of prostate cancer
Open accessThe DOI matches its Crossref record.
Abstract
Background Shear wave imaging (SWI) is a new ultrasound technique whose application facilitates quantitative tissue elasticity assessment during transrectal ultrasound biopsies of the prostate gland. The aim of this study was to determine whether SWI quantitative data can differentiate between benign and malignant areas within prostate glands in men suspected of prostate cancer (PCa).Methods We conducted a protocol-based, prospective, prebiopsy quantitative SWI of prostate glands in 50 unscreened men suspected of prostate cancer between July 2011 and May 2012. The ultrasound image of whole prostate gland was arbitrarily divided into 12 zones for sampling biopsies, as is carried out in routine clinical practice. Each region was imaged by grey scale and SWI imaging techniques. Each region was further biopsied irrespective of findings of grey scale or SWI on ultrasound. Additional biopsies were taken if SWI abnormal area was felt to be outside of these 12 zones. Quantitative assessment of SWI abnormal areas was obtained in kilopascals (kPa) from abnormal regions shown by SWI and compared with histopathology. Sensitivity, specificity, positive and negative predictive values, and likelihood ratios were calculated for SWI (histopathology was a reference standard).Results Fifty patients, with a mean age of 69 ± 6.2 years, were recruited into the study. Thirty-three (66 %) patients were diagnosed with PCa, while an additional 4 (8 %) had atypia in at least one of the 12 prostate biopsies. Thirteen (26 %) patients had a benign biopsy. Data analysed per core for SWI findings showed that for patients with PSA <20 μg/L, the sensitivity and specificity of SWI for PCa detection were 0.9 and 0.88, respectively, while in patients with PSA >20 μg/L, the sensitivity and specificity were 0.93 and 0.93, respectively. In addition, PCa had significantly higher stiffness values compared to benign tissues (p <0.05), with a trend toward stiffness differences in different Gleason grades.ConclusionSWI provides quantitative assessment of the prostatic tissues and, in our preliminary observation, provides better diagnostic accuracy than grey-scale ultrasound imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Barr, R. G., Cosgrove, D., Brock, M., Cantisani, V., Correas, J. M., Postema, A. W., Salomon, G., Tsutsumi, M., Xu, H.-X., & Dietrich, C. F. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.06.020 · Cited by 259
Deep learning based classification of breast tumors with shear-wave elastography
Zhang, Q., Xiao, Y., Dai, W., Suo, J., Wang, C., Shi, J., & Zheng, H. (2016) · Ultrasonics · doi:10.1016/j.ultras.2016.08.004 · Cited by 240
Prostate Cancer: Diagnostic Performance of Real-time Shear-Wave Elastography
Correas, J.-M., Tissier, A.-M., Khairoune, A., Vassiliu, V., Méjean, A., Hélénon, O., Memo, R., & Barr, R. G. (2015) · Radiology · doi:10.1148/radiol.14140567 · Cited by 165
Elastography imaging: the 30 year perspective
Ormachea, J., & Parker, K. J. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abca00 · Cited by 104
A urologist’s perspective on prostate cancer imaging: past, present, and future
George, A. K., Turkbey, B., Valayil, S. G., Muthigi, A., Mertan, F., Kongnyuy, M., & Pinto, P. A. (2016) · Abdominal Radiology · doi:10.1007/s00261-016-0751-6 · Cited by 30
“Moreover, stiffness values were significantly higher in areas of confirmed CaP with the potential of association with Gleason scores [103].”
Background
Metadata
- Authors
- Ahmad, S., Cao, R., Varghese, T., Bidaut, L., & Nabi, G.
- Venue
- Surgical Endoscopy
- Published
- 2013-03-23
- Volume
- 27
- Issue
- 9
- Pages
- 3280-3287
- ISSN
- 0930-2794 (ISSN-L)
- 1432-2218
- OpenAlex
- W2036985568
- Cited by
- 114
- References
- 0
- FWCI
- 10.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.