Comparative assessment of physical and cognitive ergonomics associated with robotic and traditional laparoscopic surgeries
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transoral Robotic Surgery (TORS) for Base of Tongue Neoplasms
O'Malley, B. W., Weinstein, G. S., Snyder, W., & Hockstein, N. G. (2006) · The Laryngoscope · doi:10.1097/01.mlg.0000227184.90514.1a · Cited by 740 · cited 1×
“Among patients with complex conditions, such as heart disease, cancers of the prostate, cervix, uterus, and rectum, the benefits of these uniquely robotic features include greater precision, smaller incisions, decreased blood loss, less pain, and shorter healing time [14–17].”
BackgroundPatients Benefit While Surgeons Suffer: An Impending Epidemic
Park, A., Lee, G., Seagull, J. F., Meenaghan, N., & Dexter, D. (2010) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2009.10.017 · Cited by 520 · cited 1×
“Thus, laparoscopic surgeons exposed to heavy surgical caseloads may be subjected to excessive physical fatigue, increased mental workload, and various physical symptoms, such as carpal tunnel syndrome [8–13].”
BackgroundSelf-citationPayne, T. N., & Dauterive, F. R. (2008) · Journal of Minimally Invasive Gynecology · doi:10.1016/j.jmig.2008.01.008 · Cited by 267
Stefanidis, D., Wang, F., Korndorffer, J. R., Dunne, J. B., & Scott, D. J. (2010) · Surgical Endoscopy · doi:10.1007/s00464-009-0578-0 · Cited by 250 · cited 1×
“formed intracorporeal suturing, and it was found that robotic suturing resulted in better task performance and required less mental workload and a shorter learning curve [19].”
BackgroundAssessing Mental Workload During Laparoscopic Surgery
Carswell, C. M., Clarke, D., & Seales, W. B. (2005) · Surgical Innovation · doi:10.1177/155335060501200112 · Cited by 196 · cited 1×
“Thus, laparoscopic surgeons exposed to heavy surgical caseloads may be subjected to excessive physical fatigue, increased mental workload, and various physical symptoms, such as carpal tunnel syndrome [8–13].”
BackgroundInteractive effects of physical and mental workload on subjective workload assessment
DiDomenico, A., & Nussbaum, M. A. (2008) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2008.01.012 · Cited by 178
Berguer, R., & Smith, W. (2006) · Journal of Surgical Research · doi:10.1016/j.jss.2005.10.003 · Cited by 160 · cited 1×
“In terms of performance and time, Berguer and Smith [22] showed that robotic surgery had advantages for complex tasks, such as suturing, but not with simple tasks, such as pin moving.”
BackgroundMinimal access surgery (MAS)-related surgeon morbidity syndromes
Reyes, D., Tang, B., & Cuschieri, A. (2005) · Surgical Endoscopy · doi:10.1007/s00464-005-0315-2 · Cited by 149 · cited 1×
“Laparoscopic surgical intervention offers notable benefits to patients, including smaller incisions, reduced postoperative pain, shorter hospital stay, increased postoperative comfort, and quicker return to work [5].”
BackgroundLee, E. C., Rafiq, A., Merrell, R. C., Ackerman, R., & Dennerlein, J. T. (2005) · Surgical Endoscopy · doi:10.1007/s00464-004-8213-6 · Cited by 96 · cited 1×
“[18] compared the postural and mental stresses of performing simulated surgical tasks, such as passing a spherical object through rings, running suturing, running a 32-inch-long ribbon, and cannulation with 13 novice medical students and residents using a Zeus surgical robotic system and laparoscopic surgical platform.”
MethodKlein, M. I., Warm, J. S., Riley, M. A., Matthews, G., Doarn, C. R., Donovan, J. F., & Gaitonde, K. (2012) · Journal of Endourology · doi:10.1089/end.2011.0641 · Cited by 87 · cited 1×
“Mental workload levels were similar with both systems; however, task performance with the robotic system was better and caused less mental stress [24].”
Cited by
Systematic review of measurement tools to assess surgeons' intraoperative cognitive workload
Dias, R. D., Ngo-Howard, M. C., Boskovski, M. T., Zenati, M. A., & Yule, S. J. (2018) · British Journal of Surgery · doi:10.1002/bjs.10795 · Cited by 273
Ergonomics in Surgery: A Review
Catanzarite, T., Tan-Kim, J., Whitcomb, E. L., & Menefee, S. (2018) · Female Pelvic Medicine & Reconstructive Surgery · doi:10.1097/spv.0000000000000456 · Cited by 239
Prabhu, A. S., Carbonell, A., Hope, W., Warren, J., Higgins, R., Jacob, B., Blatnik, J., Haskins, I., Alkhatib, H., Tastaldi, L., et al. (2020) · JAMA Surgery · doi:10.1001/jamasurg.2020.0034 · Cited by 216
Li, M., Ganni, S., Ponten, J., Albayrak, A., Rutkowski, A.-F., & Jakimowicz, J. (2020) · 2020 IEEE Conference on Virtual Reality and 3D User Interfaces (VR) · doi:10.1109/vr46266.2020.1581301697128 · Cited by 32
“This validated tool has already extensively been used for assessing the task demand of surgeons when performing laparoscopic surgeries or training [20, 46].”
Method
Metadata
- Authors
- Lee, G. I., Lee, M. R., Clanton, T., Sutton, E., Park, A. E., & Marohn, M. R.
- Venue
- Surgical Endoscopy
- Published
- 2013-10-03
- Volume
- 28
- Issue
- 2
- Pages
- 456-465
- ISSN
- 0930-2794 (ISSN-L)
- 1432-2218
- OpenAlex
- W2012497014
- Cited by
- 195
- References
- 13
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.