Face and construct validation of a next generation virtual reality (Gen2-VR©) surgical simulator
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
IntroductionSurgical performance is affected by distractors and interruptions to surgical workflow that exist in the operating room. However, traditional surgical simulators are used to train surgeons in a skills laboratory that does not recreate these conditions. To overcome this limitation, we have developed a novel, immersive virtual reality (Gen2-VR©) system to train surgeons in these environments. This study was to establish face and construct validity of our system.Methods and proceduresThe study was a within-subjects design, with subjects repeating a virtual peg transfer task under three different conditions: Case I: traditional VR; Case II: Gen2-VR© with no distractions and Case III: Gen2-VR© with distractions and interruptions. In Case III, to simulate the effects of distractions and interruptions, music was played intermittently, the camera lens was fogged for 10 s and tools malfunctioned for 15 s at random points in time during the simulation. At the completion of the study subjects filled in a 5-point Likert scale feedback questionnaire. A total of sixteen subjects participated in this study.ResultsFriedman test showed significant difference in scores between the three conditions (p < 0.0001). Post hoc analysis using Wilcoxon signed-rank tests with Bonferroni correction further showed that all the three conditions were significantly different from each other (Case I, Case II, p < 0.0001), (Case I, Case III, p < 0.0001) and (Case II, Case III, p = 0.009). Subjects rated that fog (mean 4.18) and tool malfunction (median 4.56) significantly hindered their performance.ConclusionThe results showed that Gen2-VR© simulator has both face and construct validity and that it can accurately and realistically present distractions and interruptions in a simulated OR, in spite of limitations of the current HMD hardware technology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Situated Learning: Legitimate Peripheral Participation
Lave, J., & Wenger, E. (1991) · Cambridge University Press eBooks · doi:10.1017/cbo9780511815355 · Cited by 35,324
Cited by
Bracq, M.-S., Michinov, E., & Jannin, P. (2019) · Simulation in Healthcare: The Journal of the Society for Simulation in Healthcare · doi:10.1097/sih.0000000000000347 · Cited by 332
Augmented reality in medical education: students’ experiences and learning outcomes
Dhar, P., Rocks, T., Samarasinghe, R. M., Stephenson, G., & Smith, C. (2021) · Medical Education Online · doi:10.1080/10872981.2021.1953953 · Cited by 325
Frederiksen, J. G., Sørensen, S. M. D., Konge, L., Svendsen, M. B. S., Nobel-Jørgensen, M., Bjerrum, F., & Andersen, S. A. W. (2020) · Surgical Endoscopy · doi:10.1007/s00464-019-06887-8 · Cited by 294
Using Virtual Reality to Improve Apathy in Residential Aged Care: Mixed Methods Study
Saredakis, D., Keage, H. A., Corlis, M., & Loetscher, T. (2020) · Journal of Medical Internet Research · doi:10.2196/17632 · Cited by 82
Li, M., Ganni, S., Ponten, J., Albayrak, A., Rutkowski, A.-F., & Jakimowicz, J. (2020) · 2020 IEEE Conference on Virtual Reality and 3D User Interfaces (VR) · doi:10.1109/vr46266.2020.1581301697128 · Cited by 32
“That environment reproduces distractions as well as generates a good sense of presence, meaning the perception of “being there” in a real OR [15, 24, 34].”
Background
Metadata
- Authors
- Sankaranarayanan, G., Li, B., Manser, K., Jones, S. B., Jones, D. B., Schwaitzberg, S., Cao, C. G. L., & De, S.
- Venue
- Surgical Endoscopy
- Published
- 2015-06-20
- Volume
- 30
- Issue
- 3
- Pages
- 979-985
- ISSN
- 0930-2794 (ISSN-L)
- 1432-2218
- OpenAlex
- W2464369960
- Cited by
- 38
- References
- 1
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.