Effectiveness of the HoloLens mixed-reality headset in minimally invasive surgery: a simulation-based feasibility study
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: HoloLens is a novel head-mounted display that has not been explored within surgical innovation research. This study aims to evaluate the HoloLens as a potential alternative to conventional monitors in endoscopic surgery. MATERIALS AND METHODS: This prospective, observational and comparative study recruited 72 participants consisting of novices (n = 28), intermediate-level (n = 24) and experts (n = 20). Participants performed ureteroscopy, within an inflatable operating environment, using a validated training model and the HoloLens mixed-reality device as a monitor. Novices also completed the assigned task using conventional monitors; whilst the experienced groups did not, due to their extensive familiarity. Outcome measures were procedural completion time and performance evaluation (OSATS) score. A final evaluation survey was distributed amongst all participants. RESULTS: The HoloLens facilitated improved outcomes for procedural times (absolute difference, - 73 s; 95% CI - 115 to - 30; P = 0.0011) and OSAT scores (absolute difference, 4.1 points; 95% CI 2.9-5.3; P < 0.0001) compared to conventional monitors. Feedback evaluation demonstrated 97% of participants agreed or strongly agreed that the HoloLens will have a role in surgical education (mean rating, 4.6 of 5; 95% CI 4.5-4.8). Furthermore, 95% of participants agreed or strongly agreed that the HoloLens is feasible to introduce clinically and will have a role within surgery (mean rating, 4.4 of 5; 95% CI 4.2-4.5). CONCLUSION: This study demonstrates that the device facilitated improved outcomes of performance in novices and was widely accepted as a surgical visual aid by all groups. The HoloLens represents a feasible alternative to the conventional setup, possibly by aligning the surgeon's visual-motor axis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Call for Auditable Virtual, Augmented and Mixed Reality
Cloete, R., Norval, C., & Singh, J. (2020) · 26th ACM Symposium on Virtual Reality Software and Technology · doi:10.1145/3385956.3418960 · Cited by 8
Metadata
- Authors
- Al Janabi, H. F., Aydin, A., Palaneer, S., Macchione, N., Al-Jabir, A., Khan, M. S., Dasgupta, P., & Ahmed, K.
- Venue
- Surgical Endoscopy
- Published
- 2019-06-18
- Volume
- 34
- Issue
- 3
- Pages
- 1143-1149
- ISSN
- 0930-2794 (ISSN-L)
- 1432-2218
- OpenAlex
- W2949380455
- Cited by
- 167
- References
- 0
- FWCI
- 17.07
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effectiveness of the HoloLens mixed-reality headset in minimally invasive surgery: a simulation-based feasibility study. https://app.cochat.ai/papers/10.1007/s00464-019-06862-3
- The paper
- Al Janabi, H. F., Aydin, A., Palaneer, S., Macchione, N., Al-Jabir, A., Khan, M. S., Dasgupta, P., & Ahmed, K. (2020). Effectiveness of the HoloLens mixed-reality headset in minimally invasive surgery: a simulation-based feasibility study. Surgical Endoscopy. https://doi.org/10.1007/s00464-019-06862-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.