Dynamic and fluid–structure interaction simulations of bioprosthetic heart valves using parametric design with T-splines and Fung-type material models
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
This paper builds on a recently developed immersogeometric fluid–structure interaction (FSI) methodology for bioprosthetic heart valve (BHV) modeling and simulation. It enhances the proposed framework in the areas of geometry design and constitutive modeling. With these enhancements, BHV FSI simulations may be performed with greater levels of automation, robustness and physical realism. In addition, the paper presents a comparison between FSI analysis and standalone structural dynamics simulation driven by prescribed transvalvular pressure, the latter being a more common modeling choice for this class of problems. The FSI computation achieved better physiological realism in predicting the valve leaflet deformation than its standalone structural dynamics counterpart.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isogeometric analysis: CAD, finite elements, NURBS, exact geometry and mesh refinement
Hughes, T. J. R., Cottrell, J. A., & Bazilevs, Y. (2005) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2004.10.008 · Cited by 6,335
Self-citationBiomechanics. Mechanical Properties of Living Tissues
Fung, Y. C., & Skalak, R. (1982) · Journal of Applied Mechanics · doi:10.1115/1.3162171 · Cited by 6,025
Brooks, A. N., & Hughes, T. J. R. (1982) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(82)90071-8 · Cited by 5,332
Peskin, C. S. (2002) · Acta Numerica · doi:10.1017/s0962492902000077 · Cited by 4,603
Mittal, R., & Iaccarino, G. (2005) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.37.061903.175743 · Cited by 3,472
Flow patterns around heart valves: A numerical method
Peskin, C. S. (1972) · Journal of Computational Physics · doi:10.1016/0021-9991(72)90065-4 · Cited by 3,047
Piegl, L., & Tiller, W. (1997) · Monographs in Visual Communication · doi:10.1007/978-3-642-59223-2 · Cited by 2,871
Nonlinear Solid Mechanics: A Continuum Approach for Engineering
Holzapfel, G. A. (2000) · Cited by 2,700
Simo, J. C., & Hughes, T. J. R. (1998) · Springer eBooks · doi:10.1007/b98904 · Cited by 2,425
Chung, J., & Hulbert, G. M. (1993) · Journal of Applied Mechanics · doi:10.1115/1.2900803 · Cited by 2,335
Fung, Y.-C. (1993) · Springer eBooks · doi:10.1007/978-1-4757-2257-4 · Cited by 2,051
Isogeometric Analysis: Toward Integration of CAD and FEA
Cottrell, J. A., Hughes, T. J. R., & Bazilevs, Y. (2009) · Wiley eBooks · doi:10.1002/9780470749081 · Cited by 1,635
Self-citationLagrangian-Eulerian finite element formulation for incompressible viscous flows
Hughes, T. J. R., Liu, W. K., & Zimmermann, T. K. (1981) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(81)90049-9 · Cited by 1,524
Donea, J., Giuliani, S., & Halleux, J. P. (1982) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(82)90128-1 · Cited by 1,517
Isogeometric shell analysis with Kirchhoff–Love elements
Kiendl, J., Bletzinger, K.-U., Linhard, J., & Wüchner, R. (2009) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2009.08.013 · Cited by 993
Self-citationStabilized Finite Element Formulations for Incompressible Flow Computations
Tezduyar, T. E. (1991) · Advances in Applied Mechanics · doi:10.1016/s0065-2156(08)70153-4 · Cited by 913
Jansen, K. E., Whiting, C. H., & Hulbert, G. M. (2000) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(00)00203-6 · Cited by 800
Prosthetic Heart Valves: Selection of the Optimal Prosthesis and Long-Term Management
Pibarot, P., & Dumesnil, J. G. (2009) · Circulation · doi:10.1161/circulationaha.108.778886 · Cited by 786
Calcification of Tissue Heart Valve Substitutes: Progress Toward Understanding and Prevention
Schoen, F. J., & Levy, R. J. (2005) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2004.06.033 · Cited by 725
Isogeometric Fluid–structure Interaction Analysis with Applications to Arterial Blood Flow
Bazilevs, Y., Calo, V. M., Zhang, Y., & Hughes, T. J. R. (2006) · Computational Mechanics · doi:10.1007/s00466-006-0084-3 · Cited by 658
Self-citationJohnson, A. A., & Tezduyar, T. E. (1994) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(94)00077-8 · Cited by 532
Weak imposition of Dirichlet boundary conditions in fluid mechanics
Bazilevs, Y., & Hughes, T. J. R. (2007) · Computers & Fluids · doi:10.1016/j.compfluid.2005.07.012 · Cited by 478
Self-citationImmersed boundary methods for simulating fluid–structure interaction
Sotiropoulos, F., & Yang, X. (2014) · Progress in Aerospace Sciences · doi:10.1016/j.paerosci.2013.09.003 · Cited by 473
Kamensky, D., Hsu, M.-C., Schillinger, D., Evans, J. A., Aggarwal, A., Bazilevs, Y., Sacks, M. S., & Hughes, T. J. R. (2015) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2014.10.040 · Cited by 470
Self-citationFinite element stabilization parameters computed from element matrices and vectors
Tezduyar, T. E., & Osawa, Y. (2000) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(00)00211-5 · Cited by 458
Computation of moving boundaries and interfaces and stabilization parameters
Tezduyar, T. E. (2003) · International Journal for Numerical Methods in Fluids · doi:10.1002/fld.505 · Cited by 456
Finite element methods for flow problems with moving boundaries and interfaces
Tezduyar, T. E. (2001) · Archives of Computational Methods in Engineering · doi:10.1007/bf02897870 · Cited by 386
Bazilevs, Y., Gohean, J. R., Hughes, T. J. R., Moser, R. D., & Zhang, Y. (2009) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2009.04.015 · Cited by 386
Self-citationHsu, M.-C., Kamensky, D., Bazilevs, Y., Sacks, M. S., & Hughes, T. J. R. (2014) · Computational Mechanics · doi:10.1007/s00466-014-1059-4 · Cited by 304
Self-citationParallel finite-element computation of 3D flows
Tezduyar, T. E., Aliabadi, S., Behr, M., et al. (1993) · Computer · doi:10.1109/2.237441 · Cited by 286
Multiscale space–time fluid–structure interaction techniques
Takizawa, K., & Tezduyar, T. E. (2011) · Computational Mechanics · doi:10.1007/s00466-011-0571-z · Cited by 283
Modeling of Congenital Hearts Alliance (MOCHA), Esmaily Moghadam, M., Bazilevs, Y., Hsia, T.-Y., Vignon-Clementel, I. E., & Marsden, A. L. (2011) · Computational Mechanics · doi:10.1007/s00466-011-0599-0 · Cited by 268
Self-citationBioprosthetic heart valves: modes of failure
Siddiqui, R. F., Abraham, J. R., & Butany, J. (2009) · Histopathology · doi:10.1111/j.1365-2559.2008.03190.x · Cited by 267
Bazilevs, Y., Hsu, M.-C., Zhang, Y., Wang, W., Kvamsdal, T., Hentschel, S., & Isaksen, J. G. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0189-7 · Cited by 244
Self-citationNobile, F., & Vergara, C. (2008) · SIAM Journal on Scientific Computing · doi:10.1137/060678439 · Cited by 206
Takizawa, K., Bazilevs, Y., & Tezduyar, T. E. (2012) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-012-9071-3 · Cited by 193
Self-citationSacks, M. S., & Schoen, F. J. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10293 · Cited by 179
Self-citationMultiscale and Stabilized Methods
Hughes, T. J. R., Scovazzi, G., & Franca, L. P. (2004) · Encyclopedia of Computational Mechanics · doi:10.1002/0470091355.ecm051.pub2 · Cited by 176
Dynamic Simulation of Bioprosthetic Heart Valves Using a Stress Resultant Shell Model
Kim, H., Lu, J., Sacks, M. S., & Chandran, K. B. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9409-4 · Cited by 141
Self-citationPatient-specific isogeometric structural analysis of aortic valve closure
Morganti, S., Auricchio, F., Benson, D. J., Gambarin, F. I., Hartmann, S., Hughes, T. J. R., & Reali, A. (2014) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2014.10.010 · Cited by 141
Self-citationTranscatheter Aortic Valve Implantation for Failing Surgical Aortic Bioprosthetic Valve
Piazza, N., Bleiziffer, S., Brockmann, G., Hendrick, R., Deutsch, M.-A., Opitz, A., Mazzitelli, D., Tassani‐Prell, P., Schreiber, C., & Lange, R. (2011) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2011.03.016 · Cited by 133
Transcatheter Aortic Valve Implantation for Failing Surgical Aortic Bioprosthetic Valve
Piazza, N., Bleiziffer, S., Brockmann, G., Hendrick, R., Deutsch, M.-A., Opitz, A., Mazzitelli, D., Tassani‐Prell, P., Schreiber, C., & Lange, R. (2011) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2011.05.007 · Cited by 128
Isogeometric Kirchhoff–Love shell formulations for biological membranes
Tepole, A. B., Kabaria, H., Bletzinger, K., & Ellen Kuhl, A. (2015) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2015.05.006 · Cited by 118
Biaxial Mechanical Response of Bioprosthetic Heart Valve Biomaterials to High In-plane Shear
Sun, W., Sacks, M. S., Sellaro, T. L., Slaughter, W. S., & Scott, M. J. (2003) · Journal of Biomechanical Engineering · doi:10.1115/1.1572518 · Cited by 115
Self-citationMirnajafi, A., Raymer, J., Scott, M. J., & Sacks, M. S. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.03.004 · Cited by 90
Self-citationLi, K., & Sun, W. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0009-3 · Cited by 85
An Experimentally Derived Stress Resultant Shell Model for Heart Valve Dynamic Simulations
Kim, H., Chandran, K. B., Sacks, M. S., & Lu, J. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9203-8 · Cited by 62
Self-citationSacks, M. S., Mirnajafi, A., Sun, W., & Schmidt, P. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.6.817 · Cited by 48
Self-citationYap, C. H., Saikrishnan, N., Tamilselvan, G., & Yoganathan, A. P. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004232 · Cited by 41
Cited by
Immersed Methods for Fluid–Structure Interaction
Griffith, B. E., & Patankar, N. A. (2020) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010719-060228 · Cited by 330
Emmert, M. Y., Schmitt, B. A., Loerakker, S., Sanders, B., Spriestersbach, H., Fioretta, E. S., Bruder, L., Brakmann, K., Motta, S. E., Lintas, V., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aan4587 · Cited by 184
“However, despite the widespread use of modeling to optimize the performance of traditional valve replacements (28, 29), it has been used only rarely to improve TEHV functionality (30, 31).”
Metadata
- Authors
- Hsu, M.-C., Kamensky, D., Xu, F., Kiendl, J., Wang, C., Wu, M. C. H., Mineroff, J., Reali, A., Bazilevs, Y., & Sacks, M. S.
- Venue
- Computational Mechanics
- Published
- 2015-05-26
- Volume
- 55
- Issue
- 6
- Pages
- 1211-1225
- ISSN
- 0178-7675 (ISSN-L)
- 1432-0924
- OpenAlex
- W384006447
- Cited by
- 260
- References
- 49
- FWCI
- 18.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.