CoChat

Concurrent validity of photogrammetric and inclinometric techniques based on assessment of anteroposterior spinal curvatures

Open access
Walicka-Cupryś, Katarzyna, Wyszyńska, Justyna, Podgórska-Bednarz, Justyna, Drzał-Grabiec, Justyna · 2018 · European Spine Journal

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

PURPOSE: The purpose of the study was to investigate correlations between parameters of anteroposterior spinal curvatures in the sagittal plane, measured with the use of photogrammetric technique and inclinometer in healthy elderly women. METHODS: Randomized study involved 50 females, ranging from 50 to 70 years of age (mean 62.26 ± 6.94); mean body mass index (BMI) 27.69 ± 4.79. The examined parameters included angle of inclination in lumbosacral spine (ALFA), thoracolumbar transition (BETA), upper thoracic segment (GAMMA), angle of lumbar lordosis (LLA) and thoracic kyphosis (TKA). Results obtained with gravitational inclinometer were compared with those identified with photogrammetry method. Statistical analyses were performed with Mann-Whitney U test, regression analysis and Bland-Altman analysis. RESULTS: In Mann-Whitney U test, with correction due to continuity, no statistically significant differences for any variable were found. Regression analysis was significant only for the variable of BETA angle. Bland-Altman coefficient for the respective angles was: ALFA 2.0%, BETA 4%, GAMMA 0%, LLA 2% and TKA 0%. CONCLUSIONS: The results acquired with gravitational inclinometer and with photogrammetric technique are comparable, as the parameters of anteroposterior spinal curvatures acquired with these two methods are found to be compatible in the case of measurements of lumbar lordosis and thoracic kyphosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00586-017-5409-8

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Flow diagram
Fig. 1 Flow diagramCC-BY · From the PDF
Fig. 3 Image of the anteroposterior curvatures obtained in photogrammetric assessment
Fig. 3 Image of the anteroposterior curvatures obtained in photogrammetric assessmentCC-BY · From the PDF
Fig. 4 Characteristic points used for measurements
Fig. 4 Characteristic points used for measurementsCC-BY · From the PDF
Image 4
CC-BY · From the PDF
Image 5
CC-BY · From the PDF
Fig. 9 Bland-Altman plot comparing measurements of angle of thoracic kyphosis (TKA) performed with the two techniques
Fig. 9 Bland-Altman plot comparing measurements of angle of thoracic kyphosis (TKA) performed with the two techniquesCC-BY · From the PDF
Image 7
CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Research works printed but not linked: 5

  1. Borek R, Sereda M, Stec W, Walicka-Cupryś K, Wilk G (2006) Ocena wpływu niepewności danych pomiarowych na rezultat wnioskowania statystycznego o rozkładzie mierzonych cech antropometrycznych (Assessment of the relationship between measurement data uncertainty and statistical inference results regarding distribution of examined anthropometric characteristics). In: Zeszyty Naukowe Politechniki Rzeszowskiej, Oficyna Wydawnicza Politechniki Rzeszowskiej, Elektrotechnika (Science papers of Rzeszów University of Technology, Publishing House of Rzeszów University of Technology, Electrical Engineering), vol 233, pp 81–88
  2. Kużdżał A, Szczygieł A, Ćwirlej A (2004) Comparison of spinal curvature parameters in sagittal plane obtained in anthropostereometric and inclinometric assessment. Post Rehabil 18:11–14
  3. Walicka-Cupryś K, Puszczałowska-Lizis E, Gaziarz K (2008) Assessment of anteroposterior spinal curvatures in middle and secondary school students. Rehabil Med 12:28–36
  4. Walicka Cupryś K, Stec M, Mrozkowiak M (2006) Comparison of spinal curvature parameters in sagittal plane measured with Moiré-based photogrammetric technique and with inclinometer. Rehabil Med 10:48–49
  5. Iunes D, Castro F, Salgado H, Moura I, Oliveira A, Bevilaqua-Grossi D (2005) Intra and inter-examiner reliability and method repeatability of postural evaluation via photogrammetry. Rev Bras Fisioter 9:327–334

Cited by

See all 31

Metadata

Authors
Walicka-Cupryś, K., Wyszyńska, J., Podgórska-Bednarz, J., & Drzał-Grabiec, J.
Affiliations
University of Rzeszów (PL)
Corresponding author
Walicka-Cupryś, Katarzyna
Venue
European Spine Journal
Published
2017-11-28
Volume
27
Issue
2
Pages
497-507
ISSN
  • 0940-6719 (ISSN-L)
  • 1432-0932
OpenAlex
W2768346542
Cited by
31
References
29
Citations by year
2026: 2 · 2025: 9 · 2024: 4 · 2023: 4 · 2022: 1 · 2021: 1 · 2020: 5 · 2019: 4 · 2018: 1
FWCI
2.81
Type
journal article
Language
en
Open access
Locations
  • European Spine Journal (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Scoliosis diagnosis and treatment
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Spine and Intervertebral Disc Pathology
  • Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
Keywords
photogrammetry, spinal curvature measurement, lumbar lordosis, thoracic kyphosis, older women, measurement agreement, concurrent validity
MeSH terms
Aged, Anthropometry, Female, Humans, Kyphosis, Lordosis, Lumbar Vertebrae, Lumbosacral Region, Middle Aged, Photogrammetry, Random Allocation, Regression Analysis, Spinal Curvatures, Thoracic Vertebrae, Body Mass Index

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Concurrent validity of photogrammetric and inclinometric techniques based on assessment of anteroposterior spinal curvatures. https://app.cochat.ai/papers/10.1007/s00586-017-5409-8
The paper
Walicka-Cupryś, K., Wyszyńska, J., Podgórska-Bednarz, J., & Drzał-Grabiec, J. (2018). Concurrent validity of photogrammetric and inclinometric techniques based on assessment of anteroposterior spinal curvatures. European Spine Journal. https://doi.org/10.1007/s00586-017-5409-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.