The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Multiplex isothermal solid-phase recombinase polymerase amplification for the specific and fast DNA-based detection of three bacterial pathogens
Open accessAbstract
We report on the development of an on-chip RPA (recombinase polymerase amplification) with simultaneous multiplex isothermal amplification and detection on a solid surface. The isothermal RPA was applied to amplify specific target sequences from the pathogens Neisseria gonorrhoeae, Salmonella enterica and methicillin-resistant Staphylococcus aureus (MRSA) using genomic DNA. Additionally, a positive plasmid control was established as an internal control. The four targets were amplified simultaneously in a quadruplex reaction. The amplicon is labeled during on-chip RPA by reverse oligonucleotide primers coupled to a fluorophore. Both amplification and spatially resolved signal generation take place on immobilized forward primers bount to expoxy-silanized glass surfaces in a pump-driven hybridization chamber. The combination of microarray technology and sensitive isothermal nucleic acid amplification at 38 °C allows for a multiparameter analysis on a rather small area. The on-chip RPA was characterized in terms of reaction time, sensitivity and inhibitory conditions. A successful enzymatic reaction is completed in <20 min and results in detection limits of 10 colony-forming units for methicillin-resistant Staphylococcus aureus and Salmonella enterica and 100 colony-forming units for Neisseria gonorrhoeae. The results show this method to be useful with respect to point-of-care testing and to enable simplified and miniaturized nucleic acid-based diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shen, F., Davydova, E. K., Du, W., Kreutz, J. E., Piepenburg, O., & Ismagilov, R. F. (2011) · Analytical Chemistry · doi:10.1021/ac200247e · Cited by 240
Cited by
Recombinase polymerase amplification: Basics, applications and recent advances
Lobato, I. M., & O'Sullivan, C. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.10.015 · Cited by 1,146
Recombinase Polymerase Amplification for Diagnostic Applications
Daher, R. K., Stewart, G., Boissinot, M., & Bergeron, M. G. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.245829 · Cited by 740
Review: a comprehensive summary of a decade development of the recombinase polymerase amplification
Li, J., Macdonald, J., & von Stetten, F. (2019) · The Analyst · doi:10.1039/c8an01621f · Cited by 648
Kersting, S., Rausch, V., Bier, F. F., & von Nickisch-Rosenegk, M. (2014) · Malaria Journal · doi:10.1186/1475-2875-13-99 · Cited by 287
Self-citation
Metadata
- Authors
- Kersting, S., Rausch, V., Bier, F. F., & von Nickisch-Rosenegk, M.
- Venue
- Microchimica Acta
- Published
- 2014-02-18
- Volume
- 181
- Issue
- 13-14
- Pages
- 1715-1723
- ISSN
- 0026-3672 (ISSN-L)
- 1436-5073
- OpenAlex
- W2051177688
- Cited by
- 183
- References
- 1
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiplex isothermal solid-phase recombinase polymerase amplification for the specific and fast DNA-based detection of three bacterial pathogens. https://app.cochat.ai/papers/10.1007/s00604-014-1198-5
- The paper
- Kersting, S., Rausch, V., Bier, F. F., & von Nickisch-Rosenegk, M. (2014). Multiplex isothermal solid-phase recombinase polymerase amplification for the specific and fast DNA-based detection of three bacterial pathogens. Microchimica Acta. https://doi.org/10.1007/s00604-014-1198-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.