The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
An electrochemical immunosensor for the corona virus associated with the Middle East respiratory syndrome using an array of gold nanoparticle-modified carbon electrodes
Open accessAbstract
AbstractThe Middle East respiratory syndrome corona virus (MERS-CoV) is highly pathogenic. An immunosensor for the determination of MERS-CoV is described here. It is based on a competitive assay carried out on an array of carbon electrodes (DEP) modified with gold nanoparticles. Recombinant spike protein S1 was used as a biomarker for MERS CoV. The electrode array enables multiplexed detection of different CoVs. The biosensor is based on indirect competition between free virus in the sample and immobilized MERS-CoV protein for a fixed concentration of antibody added to the sample. Voltammetric response is detected by monitoring the change in the peak current (typically acquired at a working potential of −0.05 V vs. Ag/AgCl) after addition of different concentrations of antigen against MERS-CoV. Electrochemical measurements using ferrocyanide/ferricyanide as a probe were recorded using square wave voltammetry (SWV). Good linear response between the sensor response and the concentrations from 0.001 to 100 ng.mL−1 and 0.01 to 10,000 ng.mL−1 were observed for MERS-CoV and HCoV, respectively. The assay was performed in 20 min with detection limit as low as 0.4 and 1.0 pg.mL−1 for HCoV and MERS-CoV, respectively. The method is highly selective over non-specific proteins such as Influenza A and B. The method is single-step, sensitive and accurate. It was successfully applied to spiked nasal samples. Graphical abstractAn electrochemical immunoassay is described for the Middle East Respiratory Syndrome Corona Virus (MERS-CoV). The method is based on a competitive assay carried out on a carbon array electrodes (DEP) nanostructured with gold nanoparticles. The array electrodes enable the multiplexed detection of different types of Corona Virus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assiri, A., Al-Tawfiq, J. A., Al-Rabeeah, A. A., Al-Rabiah, F. A., Al-Hajjar, S., Al-Barrak, A., Flemban, H., Al-Nassir, W. N., Balkhy, H. H., Al-Hakeem, R. F., et al. (2013) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(13)70204-4 · Cited by 1,435
Cited by
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Alafeef, M., Dighe, K., Moitra, P., & Pan, D. (2020) · ACS Nano · doi:10.1021/acsnano.0c06392 · Cited by 492
Huang, Y., Guo, X., Wu, Y., Chen, X., Feng, L., Xie, N., & Shen, G. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01745-z · Cited by 490
Opportunities and Challenges for Biosensors and Nanoscale Analytical Tools for Pandemics: COVID-19
Bhalla, N., Pan, Y., Yang, Z., & Payam, A. F. (2020) · ACS Nano · doi:10.1021/acsnano.0c04421 · Cited by 385
Diagnostic methods and potential portable biosensors for coronavirus disease 2019
Cui, F., & Zhou, H. S. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112349 · Cited by 373
Metadata
- Authors
- Layqah, L. A., & Eissa, S.
- Venue
- Microchimica Acta
- Published
- 2019-03-07
- Volume
- 186
- Issue
- 4
- Pages
- 224-224
- ISSN
- 0026-3672 (ISSN-L)
- 1436-5073
- OpenAlex
- W2922060538
- Cited by
- 380
- References
- 1
- FWCI
- 23.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An electrochemical immunosensor for the corona virus associated with the Middle East respiratory syndrome using an array of gold nanoparticle-modified carbon electrodes. https://app.cochat.ai/papers/10.1007/s00604-019-3345-5
- The paper
- Layqah, L. A., & Eissa, S. (2019). An electrochemical immunosensor for the corona virus associated with the Middle East respiratory syndrome using an array of gold nanoparticle-modified carbon electrodes. Microchimica Acta. https://doi.org/10.1007/s00604-019-3345-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.