Vortex-assisted dispersive liquid–liquid microextraction based on the hydrophobic deep eutectic solvent–based ferrofluid for extraction and detection of myclobutanil
Abstract
A vortex-assisted dispersive liquid-liquid microextraction (VA-DLLME) procedure using hydrophobic deep eutectic solvent-based ferrofluid (HDES-FF) as an extractant was established. The developed sample preparation method coupled with high-performance liquid chromatography-diode array detector (HPLC-DAD) was applied to the pretreatment and determination of myclobutanil (MYC) in fruit juice. Hydrophobic deep eutectic solvent, synthesized by n-decanoic acid and DL-menthol, was as a carrier and combined with magnetic nanoparticles (Fe 3 O 4 @OA) to form HDES-FF as an extractant with high extraction capacity. The synthesized materials were characterized by Fourier transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD), and vibrating sample magnetometer (VSM). Parameters affecting extraction efficiency were optimized using single-factor experiments and Box-Behnken design via response surface methodology (BBD-RSM). Parallel tests were performed three times under the optimal conditions predicted by the model, yielding an actual mean recovery of 94.77% with RSD of 2.7% (n = 3) and an enrichment factor of 41.8 ± 0.98 (mean value ± SD, n = 3). Under the optimal conditions, the linear range was 1.0-100.0 µg·mL -1 ; the limit of detection (LOD) and limit of quantification (LOQ) were 0.25 and 0.80 µg·mL -1 , respectively. The average spiked recoveries in the samples ranged from 98.2 to 100.5% with intra-day relative standard deviations (RSDs) of 1.2-3.5% (n = 3) and inter-day RSD…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Green DESs are considered replacements for organic extraction solvents because they are readily available, natural, low in toxicity and volatility, biodegradable, and biocompatible.
“In addition, green deep eutectic solvents (DESs) are noticed as a substitute for organic extraction solvents due to their convenient availability, natural sources, low toxicity and volatility, biodegradability, and biocompatibility benefits [27,28].”
Cites
Shishov, A., Volodina, N., Nechaeva, D., Gagarinova, S., & Bulatov, A. (2018) · RSC Advances · doi:10.1039/c8ra07300g · Cited by 63 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Salehi, E., Dehghan, K., Najarzadekan, H., Karami, S., & Joolaei Ahranjani, P. (2025) · Journal of Separation Science · doi:10.1002/jssc.70315 · Cited by 11 · see citing works
- Authors
- Na, Y., Gao, X., Hong, J., Zhou, X., Liang, N., & Zhao, L.
- Affiliations
- Shenyang Pharmaceutical University (CN)
- Jiangsu Ocean University (CN)
- Corresponding author
- Liang, Ning
- Zhao, Longshan
- Venue
- Microchimica Acta
- Published
- 2023-08-15
- Volume
- 190
- Issue
- 9
- Pages
- 352-352
- ISSN
- 0026-3672 (ISSN-L)
- 1436-5073
- OpenAlex
- W4385827243
- Cited by
- 31
- References
- 1
- Citations by year
- 2026: 8 · 2025: 9 · 2024: 13 · 2023: 1
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Microchimica Acta (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Youqing lift Program of Shenyang Pharmaceutical University (YQ202206)
- Middle-aged Backbone Personnel Training Program of Shenyang Pharmaceutical University (ZQN2016011)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
- Physical Sciences › Chemical Engineering › Catalysis › Ionic liquids properties and applications
- Keywords
- myclobutanil, vortex-assisted dispersive liquid-liquid microextraction, hydrophobic deep eutectic solvents, ferrofluids, magnetic nanoparticles, capric acid, DL-menthol, triazole fungicides, fruit juice, pesticide residue detection, sample preparation
- MeSH terms
- Deep Eutectic Solvents, Nitriles, Solvents, Triazoles, Spectroscopy, Fourier Transform Infrared, Liquid Phase Microextraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review