Validating a new generation filter system for visualizing 5-ALA-induced PpIX fluorescence in malignant glioma surgery: a proof of principle study
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: The BLUE 400 filter system (Carl Zeiss Meditec, Oberkochen, Germany) has provided visualization of 5-ALA-induced fluorescence-guided surgery for more than 20 years. Nevertheless, constraints, e.g., limited background discrimination during hemostasis, obstruct fluency of surgery. A novel filter with improved background visualization was developed, requiring validation regarding fluorescence discrimination. The aim of this article is to determine diagnostic accuracy and perception of protoporphyrin IX (PpIX) discrimination of a novel filter system with higher background illumination (BLUE 400 AR) compared with the gold standard, BLUE 400. Methods: A surgical microscope equipped with both BLUE 400 and BLUE 400 AR was used. Comparisons were performed on a biological basis and on the visual perception of margins. High-resolution images were compared during and after surgery by senior neurosurgeons. In a predefined biopsy algorithm, four biopsies per patient at tumor margins of PpIX fluorescence and adjacent brain were acquired using BLUE 400 AR only from regions intended for resection and assessed for cell count and density. Results: Thirty-two patients with malignant gliomas were included in this study. BLUE 400 AR markedly enhanced the brightness of the surgical field, allowing superior discrimination of brain anatomy. A total of 128 biopsies from fluorescence margins were collected. Positive predictive value (PPV) was 98.44% (95% CI, 90.06–99.77%) for malignant glioma. Residual median cell density in non-fluorescent tissue was 13% (IQR 13 to 31). Perception of the location of fluorescent margins on HD images was equivalent for both filter combinations. Conclusions: BLUE 400 AR demonstrated superior background compared with conventional BLUE 400 in malignant glioma surgery but comparable fluorescence margins and PPV. Therefore, BLUE 400 AR can be considered safe and effective in supporting malignant glioma surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stummer, W., Novotny, A., Stepp, H., Goetz, C., Bise, K., & Reulen, H. J. (2000) · Journal of Neurosurgery · doi:10.3171/jns.2000.93.6.1003 · Cited by 881
Self-citationBravo, J. J., Olson, J. D., Davis, S. C., Roberts, D. W., Paulsen, K. D., & Kanick, S. C. (2017) · Scientific Reports · doi:10.1038/s41598-017-09727-8 · Cited by 53
Erkkilä, M. T., Bauer, B., Hecker‐Denschlag, N., Madera Medina, M. J., Leitgeb, R. A., Unterhuber, A., Gesperger, J., Roetzer, T., Hauger, C., Drexler, W., et al. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201800378 · Cited by 39 · cited 1×
“Others are using hyperspectral [1] or fluorescence lifetime imaging [2] for highlighting regions of fluorescence using augmented reality overlays.”
Cited by
Erkkilä, M. T., Bauer, B., Hecker‐Denschlag, N., Madera Medina, M. J., Leitgeb, R. A., Unterhuber, A., Gesperger, J., Roetzer, T., Hauger, C., Drexler, W., et al. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201800378 · Cited by 39
5-Aminolevulinic Acid as a Theranostic Agent for Tumor Fluorescence Imaging and Photodynamic Therapy
Howley, R., Chandratre, S., & Chen, B. (2023) · Bioengineering · doi:10.3390/bioengineering10040496 · Cited by 33
Suero Molina, E., Black, D., Kaneko, S., Müther, M., & Stummer, W. (2022) · Journal of Neurosurgery · doi:10.3171/2021.12.jns211724 · Cited by 28
Self-citationStrickland, B. A., Wedemeyer, M., Ruzevick, J., Micko, A., Shahrestani, S., Daneshmand, S., Shiroishi, M. S., Hwang, D. H., Attenello, F., Chen, T., et al. (2022) · Journal of Neurosurgery · doi:10.3171/2022.1.jns212562 · Cited by 15
Metadata
- Authors
- Suero Molina, E., Stögbauer, L., Jeibmann, A., Warneke, N., & Stummer, W.
- Venue
- Acta Neurochirurgica
- Published
- 2020-02-07
- Volume
- 162
- Issue
- 4
- Pages
- 785-793
- ISSN
- 0001-6268 (ISSN-L)
- 0942-0940
- OpenAlex
- W3005338156
- Cited by
- 33
- References
- 3
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validating a new generation filter system for visualizing 5-ALA-induced PpIX fluorescence in malignant glioma surgery: a proof of principle study. https://app.cochat.ai/papers/10.1007/s00701-020-04227-7
- The paper
- Suero Molina, E., Stögbauer, L., Jeibmann, A., Warneke, N., & Stummer, W. (2020). Validating a new generation filter system for visualizing 5-ALA-induced PpIX fluorescence in malignant glioma surgery: a proof of principle study. Acta Neurochirurgica. https://doi.org/10.1007/s00701-020-04227-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.