Three-year results from a preclinical implantation study of a long-term resorbable surgical mesh with time-dependent mechanical characteristics
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this study was to evaluate the biocompatibility, local tissue effects and performance of a synthetic long-term resorbable test mesh (TIGR(®) Matrix Surgical Mesh) compared to a non-resorbable polypropylene control mesh following implantation in a sheep model. METHODS: Full-thickness abdominal wall defects were created in 14 sheep and subsequently repaired using test or control meshes. Sacrifices were made at 4, 9, 15, 24 and 36 months and results in terms of macroscopic observations, histology and collagen analysis are described for 4, 9, 15, 24 and 36 months. RESULTS: The overall biocompatibility was good, and equivalent in the test and control meshes while the resorbable mesh was characterized by a collagen deposition more similar to native connective tissue and an increased thickness of the integrating tissue. The control polypropylene mesh provoked a typical chronic inflammation persistent over the 36-month study period. As the resorbable test mesh gradually degraded it was replaced by a newly formed collagen matrix with an increasing ratio of collagen type I/III, indicating a continuous remodeling of the collagen towards a strong connective tissue. After 36 months, the test mesh was fully resorbed and only microscopic implant residues could be found in the tissue. CONCLUSIONS: This study suggests that the concept of a long-term resorbable mesh with time-dependent mechanical characteristics offers new possibilities for soft tissue repair and reinforcement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthetic biodegradable polymers as orthopedic devices
Middleton, J. C., & Tipton, A. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00101-0 · Cited by 2,741
Inflammation in surgical wound healing: Friend or foe?
Szpaderska, A. M., & DiPietro, L. A. (2005) · Surgery · doi:10.1016/j.surg.2005.01.006 · Cited by 96 · cited 1×
“inflammatory process impairs normal wound healing and tissue regeneration [5] but it may still be acceptable in the”
Background
Cited by
Design of biodegradable, implantable devices towards clinical translation
Li, C., Guo, C., Fitzpatrick, V., Ibrahim, A., Zwierstra, M. J., Hanna, P., Lechtig, A., Nazarian, A., Lin, S. J., & Kaplan, D. L. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0150-z · Cited by 808
Mechanical properties of the abdominal wall and biomaterials utilized for hernia repair
Deeken, C. R., & Lake, S. P. (2017) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2017.05.008 · Cited by 258
Deeken, C. R., & Matthews, B. D. (2013) · ISRN Surgery · doi:10.1155/2013/238067 · Cited by 139
Characterization of poly-4-hydroxybutyrate mesh for hernia repair applications
Martin, D. P., Badhwar, A., Shah, D. V., Rizk, S., Eldridge, S. N., Gagne, D. H., Ganatra, A., Darois, R. E., Williams, S. F., Tai, H.-C., et al. (2013) · Journal of Surgical Research · doi:10.1016/j.jss.2013.03.044 · Cited by 118
Ruiz-Jasbon, F., Norrby, J., Ivarsson, M.-L., & Björck, S. (2014) · Hernia · doi:10.1007/s10029-014-1249-1 · Cited by 49
Metadata
- Authors
- Hjort, H., Mathisen, T., Alves, A., Clermont, G., & Boutrand, J. P.
- Venue
- Hernia
- Published
- 2011-10-05
- Volume
- 16
- Issue
- 2
- Pages
- 191-197
- ISSN
- 1248-9204 (ISSN-L)
- 1265-4906
- OpenAlex
- W2094860052
- Cited by
- 110
- References
- 2
- FWCI
- 4.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three-year results from a preclinical implantation study of a long-term resorbable surgical mesh with time-dependent mechanical characteristics. https://app.cochat.ai/papers/10.1007/s10029-011-0885-y
- The paper
- Hjort, H., Mathisen, T., Alves, A., Clermont, G., & Boutrand, J. P. (2012). Three-year results from a preclinical implantation study of a long-term resorbable surgical mesh with time-dependent mechanical characteristics. Hernia. https://doi.org/10.1007/s10029-011-0885-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.