The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Pulsed Eddy Current Non-destructive Testing and Evaluation: A Review
Open accessAbstract
Pulsed eddy current (PEC) non-destructive testing and evaluation (NDT&E) has been around for some time and it is still attracting extensive attention from researchers around the globe, which can be witnessed through the reports reviewed in this paper. Thanks to its richness of spectral components, various applications of this technique have been proposed and reported in the literature covering both structural integrity inspection and material characterization in various industrial sectors. To support its development and for better understanding of the phenomena around the transient induced eddy currents, attempts for its modelling both analytically and numerically have been made by researchers around the world. This review is an attempt to capture the state-of-the-art development and applications of PEC, especially in the last 15 years and it is not intended to be exhaustive. Future challenges and opportunities for PEC NDT&E are also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Induction coil sensors—a review
Tumanski, S. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/3/r01 · Cited by 590
Advances in Magnetic Field Sensors
Ripka, P., & Janosek, M. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2043429 · Cited by 546
A feature extraction technique based on principal component analysis for pulsed Eddy current NDT
Sophian, A., Tian, G. Y., Taylor, D., & Rudlin, J. (2003) · NDT & E International · doi:10.1016/s0963-8695(02)00069-5 · Cited by 343
Self-citationDesign of a pulsed eddy current sensor for detection of defects in aircraft lap-joints
Sophian, A., Tian, G. Y., TAYLOR, D. J., & Rudlin, J. (2002) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(02)00195-4 · Cited by 158
Self-citationPan, M., He, Y., Tian, G. Y., et al. (2012) · NDT & E International · doi:10.1016/j.ndteint.2012.08.007 · Cited by 125
Self-citationClassification of pulsed eddy current GMR data on aircraft structures
Kim, J. J., Yang, G., Удпа, Л., & Udpa, S. S. (2009) · NDT & E International · doi:10.1016/j.ndteint.2009.10.003 · Cited by 100
Wavelet-based PCA defect classification and quantification for pulsed eddy current NDT
Tian, G., Sophian, A., TAYLOR, D. J., & Rudlin, J. (2005) · IEE Proceedings - Science Measurement and Technology · doi:10.1049/ip-smt:20045011 · Cited by 93
Self-citationPulse-modulation eddy current inspection of subsurface corrosion in conductive structures
Li, Y., Li, Y., Yan, B., et al. (2016) · NDT & E International · doi:10.1016/j.ndteint.2016.02.001 · Cited by 59
Qiu, X., Zhang, P., Wei, J., Cui, X., Wei, C. F., & Liu, L. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.09.004 · Cited by 28
Corrosion characterisation using pulsed eddy current sensor systems
Tian, G. Y., He, Y., Alamin, M., Zhang, H., & Jackson, P. (2011) · International Conference on Sensing Technology · doi:10.1109/icsenst.2011.6137030 · Cited by 2
Self-citation
Cited by
Nsengiyumva, W., Zhong, S., Lin, J., Zhang, Q., Zhong, J., & Huang, Y. (2021) · Composite Structures · doi:10.1016/j.compstruct.2020.112951 · Cited by 325
Jia, J., & Li, Y. (2023) · Sensors · doi:10.3390/s23218824 · Cited by 182
Metadata
- Authors
- Sophian, A., Tian, G., & Fan, M.
- Venue
- Chinese Journal of Mechanical Engineering
- Publisher
- Elsevier BV
- Published
- 2017-04-17
- Volume
- 30
- Issue
- 3
- Pages
- 500-514
- ISSN
- 1000-9345 (ISSN-L)
- 2192-8258
- OpenAlex
- W2616799910
- Cited by
- 325
- References
- 10
- FWCI
- 15.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulsed Eddy Current Non-destructive Testing and Evaluation: A Review. https://app.cochat.ai/papers/10.1007/s10033-017-0122-4
- The paper
- Sophian, A., Tian, G., & Fan, M. (2017). Pulsed Eddy Current Non-destructive Testing and Evaluation: A Review. Chinese Journal of Mechanical Engineering. https://doi.org/10.1007/s10033-017-0122-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.