US Regulatory Considerations for Low Field Magnetic Resonance Imaging Systems
Open accessAbstract
Although there has been a resurgence of interest in low field magnetic resonance imaging (MRI) systems in recent years, low field MRI is not a new concept. FDA has a long history of evaluating the safety and effectiveness of MRI systems encompassing a wide range of field strengths. Many systems seeking marketing authorization today include new technological features (such as artificial intelligence), but this does not fundamentally change the regulatory paradigm for MR systems. In this review, we discuss some of the US regulatory considerations for low field magnetic resonance imaging (MRI) systems, including applicability of existing laws and regulations and how the U.S. Food and Drug Administration (FDA) evaluates low field MRI systems for market authorization. We also discuss regulatory considerations in the review of low field MRI systems incorporating novel AI technology. We foresee that MRI systems of all field strengths intended for general diagnostic use will continue to be evaluated for marketing clearance by the metric of substantial equivalence set forth in the premarket notification pathway.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
User characteristics, interface design, and the environment of use can influence safety and effectiveness.
“Factors such as user characteristics, interface design, and the environment of use can influence safety and effectiveness [327].”
From Toward Safer Diagnoses: A SEIPS-Based Narrative Review of Diagnostic Errors (2026) · cites this paper as [327]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 6 · Cited by 5
Research works printed but not linked: 4
- [4]Docket Nos. 87P-0214/CP through 87P0214/CP0013. (1989) Federal Register. 54(20):5077–8. 10291710
- [28]Yu AC Eng J One algorithm may not fit all: how selection bias affects machine learning performance Radiographics 2020 10.1148/rg.2020200040 32976062 · DOI
- [29]Antun V Renna F Poon C Hansen AC On instabilities of deep learning in image reconstruction and the potential costs of AI Proc Natl Acad Sci U S A 2020 10.1073/pnas.1907377117 32393633 PMC7720232 · DOI
- [32]Bhusal B Nguyen B Sanpitak PP Vu J Elahi B Rosenow J Nolt MJ Lopez-Rosado R Pilitsis J DiMarzio M Golestanirad L Effect of device configuration and patient's Body composition on the RF heating and nonsusceptibility artifact of deep brain stimulation implants during MRI at 1.5 T and 3T J Magn Reson Imaging 2021 10.1002/jmri.27346 32860322 · DOI
- Authors
- Krainak, D. M., Zeng, R., Li, N., Woods, T. O., & Delfino, J. G.
- Affiliations
- United States Food and Drug Administration (US)
- Corresponding author
- Delfino, Jana Gut
- Venue
- Magnetic Resonance Materials in Physics, Biology and Medicine
- Published
- 2023-05-16
- Volume
- 36
- Issue
- 3
- Pages
- 347-354
- ISSN
- 0968-5243 (ISSN-L)
- 1352-8661
- PMC
- PMC10386952
- OpenAlex
- W4376642284
- Cited by
- 5
- References
- 6
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 3
- FWCI
- 0.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Magnetic Resonance Materials in Physics Biology and Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Health Information Management › Healthcare Regulation
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Health Professions › Medical Laboratory Technology › Quality and Safety in Healthcare
- Keywords
- low-field MRI, substantial equivalence, premarket notification, artificial intelligence in medical devices
- MeSH terms
- Artificial Intelligence, Magnetic Resonance Imaging, United States, United States Food and Drug Administration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review