PURPOSE: This study compared outcomes between end-to-end anastomosis and other anastomotic configurations after intestinal resection for patients with Crohn's disease by using meta-analytical techniques. METHODS: Comparative studies published between 1992 and 2005 of end-to-end anastomosis vs. other anastomotic configurations were included. Using a random effects model, end points evaluated were short-term complications and perianastomotic recurrence of Crohn's disease. Heterogeneity was assessed and sensitivity analysis was performed to account for bias in patient selection. RESULTS: Eight studies (2 prospective, randomized, controlled trials; 1 nonrandomized, prospective; 5 nonrandomized, retrospective studies) reported on 661 patients who underwent 712 anastomoses, of which 383 (53.8 percent) were sutured end-to-end anastomosis and 329 (46.2 percent) were other anastomotic configurations (259 stapled side-to-side, 59 end-to-side or side-to-end, 11 stapled circular end-to-end). Anastomotic leak rate was significantly reduced in the other anastomotic configurations group (odds ratio (OR), 4.37; P = 0.02) and remained significantly lower in studies comparing only side-to-side anastomosis vs. end-to-end anastomosis (OR, 4.37; P = 0.02) and studies including only ileocolonic anastomosis (OR, 3.8; P = 0.05). Overall postoperative complications (OR, 2.64; P < 0.001), complications other than anastomotic leak (OR, 1.89; P = 0.04), and postoperative hospital stay (weighted mean difference, 2.81; P = 0.007) were significantly reduced in the side-to-side anastomosis group when considering studies comparing only side-to-side anastomosis vs. end-to-end anastomosis. There was no significant difference between the groups in perianastomotic recurrence and reoperation needed because of perianastomotic recurrence. CONCLUSIONS: End-to-end anastomosis after resection for Crohn's disease may be associated with increased anastomotic leak rates. Side-to-side anastomosis may lead to fewer anastomotic leaks and overall postoperative complications, a shorter hospital stay, and a perianastomotic recurrence rate comparable to end-to-end anastomosis. Further randomized, controlled trials should be performed for confirmation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722 · cited 2×
“In this type of model, it is assumed that there is variation between studies and therefore the calculated odds ratio has a more conservative value.(31,32) Yates_ correction was used for those studies that contained a zero in one cell for the number of events of interest in one of the two groups.”
MethodMeta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552 · cited 2×
“In this type of model, it is assumed that there is variation between studies and therefore the calculated odds ratio has a more conservative value.(31,32) Yates_ correction was used for those studies that contained a zero in one cell for the number of events of interest in one of the two groups.”
Method(2014) · Medical Entomology and Zoology · Cited by 17,633
Assessing the quality of reports of randomized clinical trials: Is blinding necessary?
Jadad, A. R., Moore, R. A., Carroll, D., Jenkinson, C., Reynolds, D. J. M., Gavaghan, D. J., & McQuay, H. J. (1996) · Controlled Clinical Trials · doi:10.1016/0197-2456(95)00134-4 · Cited by 17,582 · cited 2×
“The quality of the studies could not be assessed by using the instrument developed by Jadad et al.(38) for assessing randomized, clinical trials or MINORS (methodologic index for nonrandomized studies) developed by Slim et al.”
MethodStatistical Aspects of the Analysis of Data From Retrospective Studies of Disease
(1959) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/22.4.719 · Cited by 14,689 · cited 1×
“Yates_ correction was used for those studies that contained a zero in one cell for the number of events of interest in one of the two groups.(33,34) A study was discarded from the meta-analysis of an outcome if there were no events for both EEA and OAC groups.”
MethodSlim, K., Nini, E., Forestier, D., Kwiatkowski, F., Panis, Y., & Chipponi, J. (2003) · ANZ Journal of Surgery · doi:10.1046/j.1445-2197.2003.02748.x · Cited by 7,603 · cited 1×
“(1992)11 NRR 47 (47) 39 ( 39 ) 31 (12–60) 31 (14–68) 1,2,3,4,5, 6,7,10,11 a,b,c,e,f,g, h,n,p 7”
Moher, D., Cook, D. J., Eastwood, S., Olkin, I., Rennie, D., & Stroup, D. F. (1999) · The Lancet · doi:10.1016/s0140-6736(99)04149-5 · Cited by 4,826
Beta blockade during and after myocardial infarction: An overview of the randomized trials
Yusuf, S., Peto, R., Lewis, J., Collins, R., & Sleight, P. (1985) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(85)80003-7 · Cited by 3,205 · cited 1×
“Yates_ correction was used for those studies that contained a zero in one cell for the number of events of interest in one of the two groups.(33,34) A study was discarded from the meta-analysis of an outcome if there were no events for both EEA and OAC groups.”
MethodEvaluating non-randomised intervention studies
Deeks, J., Dinnes, J., D'Amico, R., Sowden, A., Sakarovitch, C., Song, F., Petticrew, M., & Altman, D. (2003) · Health Technology Assessment · doi:10.3310/hta7270 · Cited by 2,907
Predictability of the postoperative course of Crohn's disease
Rutgeerts, P., Geboes, K., Vantrappen, G., Beyls, J., Kerremans, R., & Hiele, M. (1990) · Gastroenterology · doi:10.1016/0016-5085(90)90613-6 · Cited by 1,820
Cited by
Dignass, A., Van Assche, G., Lindsay, J. O., Lémann, M., Söderholm, J., Colombel, J. F., Danese, S., D'Hoore, A., Gassull, M., Gomollón, F., et al. (2010) · Journal of Crohn's and Colitis · doi:10.1016/j.crohns.2009.12.002 · Cited by 1,498
Guidelines for the management of inflammatory bowel disease in adults
Mowat, C., Cole, A., Windsor, A., Ahmad, T., Arnott, I., Driscoll, R., Mitton, S., Orchard, T., Rutter, M., Younge, L., et al. (2011) · Gut · doi:10.1136/gut.2010.224154 · Cited by 1,419
ECCO Guidelines on Therapeutics in Crohn’s Disease: Surgical Treatment
Adamina, M., Bonovas, S., Raine, T., Spinelli, A., Warusavitarne, J., Armuzzi, A., Bachmann, O., Bager, P., Biancone, L., Bokemeyer, B., et al. (2020) · Journal of Crohn's and Colitis · doi:10.1093/ecco-jcc/jjz187 · Cited by 1,106
Evidence-based clinical practice guidelines for inflammatory bowel disease
Matsuoka, K., Kobayashi, T., Ueno, F., Matsui, T., Hirai, F., Inoue, N., Kato, J., Kobayashi, K., Kobayashi, K., Koganei, K., et al. (2018) · Journal of Gastroenterology · doi:10.1007/s00535-018-1439-1 · Cited by 698
Stapled versus handsewn methods for ileocolic anastomoses
Choy, P. Y. G., Bissett, I. P., Docherty, J. G., Parry, B. R., Merrie, A., & Fitzgerald, A. (2011) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004320.pub3 · Cited by 346
ECCO Guidelines on Therapeutics in Crohn’s Disease: Surgical Treatment
Adamina, M., Minozzi, S., Warusavitarne, J., Buskens, C. J., Chaparro, M., Verstockt, B., Kopylov, U., Yanai, H., Vavricka, S. R., Sigall-Boneh, R., et al. (2024) · Journal of Crohn's and Colitis · doi:10.1093/ecco-jcc/jjae089 · Cited by 188
ANACO Study Group, Frasson, M., Granero-Castro, P., Ramos Rodríguez, J. L., Flor-Lorente, B., Braithwaite, M., Martí Martínez, E., Álvarez Pérez, J. A., Codina Cazador, A., Espí, A., et al. (2016) · International Journal of Colorectal Disease · doi:10.1007/s00384-015-2376-6 · Cited by 165
“Other meta-analyses previously published comparing stapled and hand-sewn anastomosis in colorectal surgery did not find any differences in terms of AL [25, 26].”
BackgroundInflammatory Bowel Disease: Crohn’s disease and ulcerative colitis
Wehkamp, J., Götz, M., Herrlinger, K., Steurer, W., & Stange, E. F. (2016) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2016.0072 · Cited by 160
Metadata
- Authors
- Simillis, C., Purkayastha, S., Yamamoto, T., Strong, S. A., Darzi, A. W., & Tekkis, P. P.
- Venue
- Diseases of the Colon & Rectum
- Published
- 2007-10
- Volume
- 50
- Issue
- 10
- Pages
- 1674-1687
- ISSN
- 0012-3706 (ISSN-L)
- OpenAlex
- W2014229988
- Cited by
- 210
- References
- 50
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.