The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Electroosmotic pumps and their applications in microfluidic systems
Open accessAbstract
Electroosmotic pumping is receiving increasing attention in recent years owing to the rapid development in micro total analytical systems. Compared with other micropumps, electroosmotic pumps (EOPs) offer a number of advantages such as creation of constant pulse-free flows and elimination of moving parts. The flow rates and pumping pressures of EOPs matches well with micro analysis systems. The common materials and fabrication technologies make it readily integrateable with lab-on-a-chip devices. This paper reviews the recent progress on EOP fabrications and applications in order to promote the awareness of EOPs to researchers interested in using micro- and nano-fluidic devices. The pros and cons of EOPs are also discussed, which helps these researchers in designing and constructing their micro platforms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mathematical Theory of the Kinetics of the Coagulation of Colloidal Solutions
Smoluchowski, M. (1917) · Zeitschrift für Physikalische Chemie · Cited by 2,814
Laser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
Modern Electrochemistry: An Introduction to an Interdisciplinary Area Volume 1
Bockris, J. O., & Reddy, A. K. N. (1970) · Springer eBooks · doi:10.1007/978-1-4615-8600-5 · Cited by 1,797
Růžička, J., & Stewart, J. W. B. (1975) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)89421-0 · Cited by 1,511
Studien über electrische Grenzschichten
Helmholtz, H. (1879) · Annalen der Physik · doi:10.1002/andp.18792430702 · Cited by 955
Bemerkungen zu der Abhandlung der HH. Weselsky und Benedikt „Ueber einige Azoverbindungen”︁
Griess, P. (1879) · Berichte der deutschen chemischen Gesellschaft · doi:10.1002/cber.187901201117 · Cited by 941
Colorimetric Microdetermination of Nitrogen Dioxide in Atmosphere
Saltzman, B. E. (1954) · Analytical Chemistry · doi:10.1021/ac60096a025 · Cited by 685
Ion-Enrichment and Ion-Depletion Effect of Nanochannel Structures
Pu, Q., Yun, J., Temkin, H., & Liu, S. (2004) · Nano Letters · doi:10.1021/nl0494811 · Cited by 532
Self-citationAC Electric-Field-Induced Fluid Flow in Microelectrodes
Ramos, A., Morgan, H., Green, N. G., & Castellanos, A. (1999) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1999.6346 · Cited by 527
Monolithic silica columns for high-efficiency chromatographic separations
Tanaka, N., Kobayashi, H., Ishizuka, N., Minakuchi, H., Nakanishi, K., Hosoya, K., & Ikegami, T. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)01582-5 · Cited by 497
Cited by
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Mixing in microfluidic devices and enhancement methods
Ward, K., & Fan, Z. H. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/9/094001 · Cited by 453
Organ-on-chip models of cancer metastasis for future personalized medicine: From chip to the patient
Caballero, D., Kaushik, S., Correlo, V. M., Oliveira, J. M., Reis, R. L., & Kundu, S. C. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.005 · Cited by 221
Metadata
- Authors
- Wang, X., Cheng, C., Wang, S., & Liu, S.
- Venue
- Microfluidics and Nanofluidics
- Published
- 2009-01-09
- Volume
- 6
- Issue
- 2
- Pages
- 145-162
- ISSN
- 1613-4982 (ISSN-L)
- 1613-4990
- OpenAlex
- W1980980118
- Cited by
- 343
- References
- 24
- FWCI
- 8.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electroosmotic pumps and their applications in microfluidic systems. https://app.cochat.ai/papers/10.1007/s10404-008-0399-9
- The paper
- Wang, X., Cheng, C., Wang, S., & Liu, S. (2009). Electroosmotic pumps and their applications in microfluidic systems. Microfluidics and Nanofluidics. https://doi.org/10.1007/s10404-008-0399-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.