Confocal Endomicroscopy: Instrumentation and Medical Applications
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Advances in fiber optic technology and miniaturized optics and mechanics have propelled confocal endomicroscopy into the clinical realm. This high resolution, non-invasive imaging technology provides the ability to microscopically evaluate cellular and sub-cellular features in tissue in vivo by optical sectioning. Because many cancers originate in epithelial tissues accessible by endoscopes, confocal endomicroscopy has been explored to detect regions of possible neoplasia at an earlier stage by imaging morphological features in vivo that are significant in histopathologic evaluation. This technique allows real-time assessment of tissue which may improve diagnostic yield by guiding biopsy. Research and development continues to reduce the overall size of the imaging probe, increase the image acquisition speed, and improve resolution and field of view of confocal endomicroscopes. Technical advances will continue to enable application to less accessible organs and more complex systems in the body. Lateral and axial resolutions down to 0.5 and 3 μm, respectively, field of view as large as 800 × 450 μm, and objective lens and total probe outer diameters down to 0.35 and 1.25 mm, respectively, have been achieved. We provide a review of the historical developments of confocal imaging in vivo, the evolution of endomicroscope instrumentation, and the medical applications of confocal endomicroscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Memoir on inventing the confocal scanning microscope
Minsky, M. (1988) · Scanning · doi:10.1002/sca.4950100403 · Cited by 1,556
In Vivo Confocal Scanning Laser Microscopy of Human Skin: Melanin Provides Strong Contrast
Rajadhyaksha, M., Grossman, M., Esterowitz, D., Webb, R. H., & Rox Anderson, R. (1995) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12606215 · Cited by 1,093
Confocal laser endoscopy for diagnosing intraepithelial neoplasias and colorectal cancer in vivo
Kiesslich, R., Burg, J., Vieth, M., Gnaendiger, J., Enders, M., Delaney, P., Polglase, A., McLaren, W., Janell, D., Thomas, S., et al. (2004) · Gastroenterology · doi:10.1053/j.gastro.2004.06.050 · Cited by 843
Rajadhyaksha, M., González, S., Zavislan, J. M., Rox Anderson, R., & Webb, R. H. (1999) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.1999.00690.x · Cited by 834
Fiber-optic fluorescence imaging
Flusberg, B. A., Cocker, E. D., Piyawattanametha, W., Jung, J. C., Cheung, E. L. M., & Schnitzer, M. J. (2005) · Nature Methods · doi:10.1038/nmeth820 · Cited by 732
A Miniature Head-Mounted Two-Photon Microscope
Helmchen, F., Fee, M. S., Tank, D. W., & Denk, W. (2001) · Neuron · doi:10.1016/s0896-6273(01)00421-4 · Cited by 622
Receptor-targeted optical imaging of tumors with near-infrared fluorescent ligands
Becker, A., Hessenius, C., Licha, K., Ebert, B., Sukowski, U., Semmler, W., Wiedenmann, B., & Grötzinger, C. (2001) · Nature Biotechnology · doi:10.1038/86707 · Cited by 518
In Vivo Histology of Barrett’s Esophagus and Associated Neoplasia by Confocal Laser Endomicroscopy
Kiesslich, R., Gossner, L., Goetz, M., Dahlmann, A., Vieth, M., Stolte, M., Hoffman, A., Jung, M., Nafe, B., Galle, P. R., et al. (2006) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2006.05.010 · Cited by 473
Detection of colonic dysplasia in vivo using a targeted heptapeptide and confocal microendoscopy
Hsiung, P.-L., Hardy, J., Friedland, S., Soetikno, R., Du, C. B., Wu, A. P., Sahbaie, P., Crawford, J. M., Lowe, A. W., Contag, C. H., et al. (2008) · Nature Medicine · doi:10.1038/nm1692 · Cited by 444
A fluorescence confocal endomicroscope for in vivo microscopy of the upper- and the lower-GI tract
Polglase, A. L., McLaren, W. J., Skinner, S. A., Kießlich, R., Neurath, M. F., & Delaney, P. M. (2005) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2005.05.021 · Cited by 389
Cited by
Digital confocal microscopy through a multimode fiber
Loterie, D., Farahi, S., Papadopoulos, I., Goy, A., Psaltis, D., & Moser, C. (2015) · Optics Express · doi:10.1364/oe.23.023845 · Cited by 180
Jedrzejczak-Silicka, M. (2017) · New Insights into Cell Culture Technology · doi:10.5772/66905 · Cited by 87
Metadata
- Authors
- Jabbour, J. M., Saldua, M. A., Bixler, J. N., & Maitland, K. C.
- Venue
- Annals of Biomedical Engineering
- Published
- 2011-10-13
- Volume
- 40
- Issue
- 2
- Pages
- 378-397
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2058856043
- Cited by
- 173
- References
- 46
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Confocal Endomicroscopy: Instrumentation and Medical Applications. https://app.cochat.ai/papers/10.1007/s10439-011-0426-y
- The paper
- Jabbour, J. M., Saldua, M. A., Bixler, J. N., & Maitland, K. C. (2012). Confocal Endomicroscopy: Instrumentation and Medical Applications. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-011-0426-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.