Automated Estimation of Collagen Fibre Dispersion in the Dermis and its Contribution to the Anisotropic Behaviour of Skin
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Collagen fibres play an important role in the mechanical behaviour of many soft tissues. Modelling of such tissues now often incorporates a collagen fibre distribution. However, the availability of accurate structural data has so far lagged behind the progress of anisotropic constitutive modelling. Here, an automated process is developed to identify the orientation of collagen fibres using inexpensive and relatively simple techniques. The method uses established histological techniques and an algorithm implemented in the MATLAB image processing toolbox. It takes an average of 15 s to evaluate one image, compared to several hours if assessed visually. The technique was applied to histological sections of human skin with different Langer line orientations and a definite correlation between the orientation of Langer lines and the preferred orientation of collagen fibres in the dermis \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$(p<0.001, R^{2}= 0.95)$$\end{document} was observed. The structural parameters of the Gasser–Ogden–Holzapfel (GOH) model were all successfully evaluated. The mean dispersion factor for the dermis was \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\kappa = 0.1404 \pm 0.0028.$$\end{document} The constitutive parameters μ, k1 and k2 were evaluated through physically-based, least squares curve-fitting of experimental test data. The values found for μ, k1 and k2 were 0.2014 MPa, 243.6 and 0.1327, respectively. Finally, the above model was implemented in ABAQUS/Standard and a finite element (FE) computation was performed of uniaxial extension tests on human skin. It is expected that the results of this study will assist those wishing to model skin, and that the algorithm described will be of benefit to those who wish to evaluate the collagen dispersion of other soft tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Threshold Selection Method from Gray-Level Histograms
Otsu, N. (1979) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1979.4310076 · Cited by 43,398
Hyperelastic modelling of arterial layers with distributed collagen fibre orientations
Gasser, T. C., Ogden, R. W., & Holzapfel, G. A. (2006) · Journal of The Royal Society Interface · doi:10.1098/rsif.2005.0073 · Cited by 2,411 · cited 9×
“where b is the concentration parameter associated with the Von Mises distribution and Θ is the mean orientation of fibres (for a graph of the variation of the dispersion parameter κ with the concentration parameter b, see Gasser et al [10]).”
BackgroundMethodInfluentialFitting hyperelastic models to experimental data
Ogden, R. W., Saccomandi, G., & Sgura, I. (2004) · Computational Mechanics · doi:10.1007/s00466-004-0593-y · Cited by 775 · cited 2×
“It is possible that the optimisation procedure finds a local minimum and assumes that this is the global minimum [23].”
BackgroundSelf-citationCharacterization of the anisotropic mechanical properties of excised human skin
Ní Annaidh, A., Bruyère, K., Destrade, M., Gilchrist, M. D., & Otténio, M. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2011.08.016 · Cited by 763
Self-citationConstitutive equations for fibrous connective tissues
Lanir, Y. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90041-6 · Cited by 741 · cited 1×
“Lanir [19] was the first to attempt to account for fibre dispersion.”
BackgroundHOLZAPFEL, G. A. (2001) · Handbook of Materials Behavior Models · doi:10.1016/b978-012443341-0/50107-1 · Cited by 415
Holzapfel, G. A. (2005) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2005.05.006 · Cited by 394 · cited 1×
“An extensive experimental data set would include planar biaxial tests with in-plane shear and separate through thickness shear tests [9][15], however in the absence of these advanced testing protocols tensile tests coupled with a histological study of the collagen fibre alignment can be used for reasonable determinati…”
Finite element modeling of human skin using an isotropic, nonlinear elastic constitutive model
Bischoff, J. E., Arruda, E. M., & Grosh, K. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00018-x · Cited by 213 · cited 1×
“Due to the complex nature of fibre arrangements, such tissues are often represented as either isotropic or transversely isotropic [6, 2, 3].”
BackgroundOn planar biaxial tests for anisotropic nonlinearly elastic solids. A continuum mechanical framework
Holzapfel, G. A., & Ogden, R. W. (2009) · Mathematics and Mechanics of Solids · doi:10.1177/1081286507084411 · Cited by 206 · cited 1×
“An extensive experimental data set would include planar biaxial tests with in-plane shear and separate through thickness shear tests [9][15], however in the absence of these advanced testing protocols tensile tests coupled with a histological study of the collagen fibre alignment can be used for reasonable determinati…”
Yasui, T., Tohno, Y., & Araki, T. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1644116 · Cited by 149
Cited by
Characterization of the anisotropic mechanical properties of excised human skin
Ní Annaidh, A., Bruyère, K., Destrade, M., Gilchrist, M. D., & Otténio, M. (2012) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2011.08.016 · Cited by 763
Self-citationBandodkar, A. J., Molinnus, D., Mirza, O., Guinovart, T., Windmiller, J. R., Valdés-Ramírez, G., Andrade, F. J., Schöning, M. J., & Wang, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.039 · Cited by 490
Skin mechanical properties and modeling: A review
Joodaki, H., & Panzer, M. B. (2018) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411918759801 · Cited by 480
Bioprinting: From Tissue and Organ Development to in Vitro Models
Mota, C., Camarero-Espinosa, S., Baker, M. B., Wieringa, P., & Moroni, L. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00789 · Cited by 345
Strain rate and anisotropy effects on the tensile failure characteristics of human skin
Ottenio, M., Tran, D., Ní Annaidh, A., Gilchrist, M. D., & Bruyère, K. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.10.006 · Cited by 220
Self-citation
Metadata
- Authors
- Ní Annaidh, A., Bruyère, K., Destrade, M., Gilchrist, M. D., Maurini, C., Otténio, M., & Saccomandi, G.
- Venue
- Annals of Biomedical Engineering
- Published
- 2012-03-17
- Volume
- 40
- Issue
- 8
- Pages
- 1666-1678
- ISSN
- 0090-6964 (ISSN-L)
- 1573-9686
- OpenAlex
- W2159227957
- Cited by
- 202
- References
- 23
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.