The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Expansion of human mesenchymal stem cells on microcarriers
Open accessAbstract
The effects on human mesenchymal stem cell growth of choosing either of two spinner flask impeller geometries, two microcarrier concentrations and two cell concentrations (seeding densities) were investigated. Cytodex 3 microcarriers were not damaged when held at the minimum speed, NJS, for their suspension, using either impeller, nor was there any observable damage to the cells. The maximum cell density was achieved after 8–10 days of culture with up to a 20-fold expansion in terms of cells per microcarrier. An increase in microcarrier concentration or seeding density generally had a deleterious or neutral effect, as previously observed for human fibroblast cultures. The choice of impeller was significant, as was incorporation of a 1 day delay before agitation to allow initial attachment of cells. The best conditions for cell expansion on the microcarriers in the flasks were 3,000 microcarriers ml−1 (ca. 1 g dry weight l−1), a seeding density of 5 cells per microcarrier with a 1 day delay before agitation began at NJS (30 rpm), using a horizontally suspended flea impeller with an added vertical paddle. These findings were interpreted using Kolmogorov’s theory of isotropic turbulence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reactor Engineering in Large Scale Animal Cell Culture
Nienow, A. W. (2006) · Cytotechnology · doi:10.1007/s10616-006-9005-8 · Cited by 433 · cited 4×
“However, even for mammalian cells, little work has been done to study the impact of the fluid dynamic conditions on bioreactor performance because quite early in the development of that technology, free suspension culture became available and quickly dominated because it is easier to perform (Schutt et al. 1997; Nieno…”
BackgroundMethodInfluentialSelf-citation
Cited by
Scaffolding Biomaterials for 3D Cultivated Meat: Prospects and Challenges
Bomkamp, C., Skaalure, S. C., Fernando, G. F., Ben‐Arye, T., Swartz, E. W., & Specht, E. A. (2022) · Advanced Science · doi:10.1002/advs.202102908 · Cited by 349
Quality cell therapy manufacturing by design
Lipsitz, Y. Y., Timmins, N. E., & Zandstra, P. W. (2016) · Nature Biotechnology · doi:10.1038/nbt.3525 · Cited by 311
Chen, A. K.-L., Reuveny, S., & Oh, S. K. W. (2013) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.03.006 · Cited by 292
Teixeira, F. G., Panchalingam, K. M., Anjo, S. I., Manadas, B., Pereira, R., Sousa, N., Salgado, A. J., & Behie, L. A. (2015) · Stem Cell Research & Therapy · doi:10.1186/s13287-015-0124-z · Cited by 87
Needle to needle robot‐assisted manufacture of cell therapy products
Ochs, J., Hanga, M. P., Shaw, G., Duffy, N., Kulik, M., Tissin, N., Reibert, D., Biermann, F., Moutsatsou, P., Ratnayake, S., et al. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10387 · Cited by 18
Self-citation
Metadata
- Authors
- Hewitt, C. J., Lee, K., Nienow, A. W., Thomas, R. J., Smith, M., & Thomas, C. R.
- Venue
- Biotechnology Letters
- Published
- 2011-07-17
- Volume
- 33
- Issue
- 11
- Pages
- 2325-2335
- ISSN
- 0141-5492 (ISSN-L)
- 1573-6776
- OpenAlex
- W2013246140
- Cited by
- 163
- References
- 1
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Expansion of human mesenchymal stem cells on microcarriers. https://app.cochat.ai/papers/10.1007/s10529-011-0695-4
- The paper
- Hewitt, C. J., Lee, K., Nienow, A. W., Thomas, R. J., Smith, M., & Thomas, C. R. (2011). Expansion of human mesenchymal stem cells on microcarriers. Biotechnology Letters. https://doi.org/10.1007/s10529-011-0695-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.