The frequency of missed breast cancers in women participating in a high-risk MRI screening program
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the frequency of missed cancers on breast MRI in women participating in a high-risk screening program. METHODS: Patient files from women who participated in an increased risk mammography and MRI screening program (2003-2014) were coupled to the Dutch National Cancer Registry. For each cancer detected, we determined whether an MRI scan was available (0-24 months before cancer detection), which was reported to be negative. These negative MRI scans were in consensus re-evaluated by two dedicated breast radiologists, with knowledge of the cancer location. Cancers were scored as invisible, minimal sign, or visible. Additionally, BI-RADS scores, background parenchymal enhancement, and image quality (IQ; perfect, sufficient, bad) were determined. Results were stratified by detection mode (mammography, MRI, interval cancers, or cancers in prophylactic mastectomies) and patient characteristics (presence of BRCA mutation, age, menopausal state). RESULTS: Negative prior MRI scans were available for 131 breast cancers. Overall 31% of cancers were visible at the initially negative MRI scan and 34% of cancers showed a minimal sign. The presence of a BRCA mutation strongly reduced the likelihood of visible findings in the last negative MRI (19 vs. 46%, P < 0.001). Less than perfect IQ increased the likelihood of visible findings and minimal signs in the negative MRI (P = 0.021). CONCLUSION: This study shows that almost one-third of cancers detected in a high-risk screening program are already visible at the last negative MRI scan, and even more in women without BRCA mutations. Regular auditing and double reading for breast MRI screening is warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“if a patients' high-risk genetic mutation is known to radiologists, the number of missed breast lesions on MRI scans is known to decrease considerably [38].”
From Operationalising ethics in artificial intelligence for healthcare: a framework for AI developers (2023) · cites this paper as [38]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-Analysis of BRCA1 and BRCA2 Penetrance
Chen, S., & Parmigiani, G. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2006.09.1066 · Cited by 1,802 · cited 1×
“The much higher a priori chance of these women to develop breast cancer compared to other women at increased risk [25], along with the fast growth of cancers in these women [26], leads to lowering Table 2 Visibility of lesions on prior negative MRI scans, stratified by patient and imaging factors”
BackgroundMagnetic resonance imaging of the breast: Recommendations from the EUSOMA working group
Sardanelli, F., Boetes, C., Borisch, B., Decker, T., Federico, M., Gilbert, F. J., Helbich, T., Heywang-Köbrunner, S. H., Kaiser, W. A., Kerin, M. J., et al. (2010) · European Journal of Cancer · doi:10.1016/j.ejca.2010.02.015 · Cited by 992 · cited 1×
“However, all examinations were performed with at the time state-of-the-art equipment and imaging quality was in adherence with international recommendations [30, 31].”
BackgroundBreast MRI: guidelines from the European Society of Breast Imaging
Mann, R. M., Kuhl, C. K., Kinkel, K., & Boetes, C. (2008) · European Radiology · doi:10.1007/s00330-008-0863-7 · Cited by 839
Self-citationKuhl, C., Weigel, S., Schrading, S., Arand, B., Bieling, H., König, R., Tombach, B., Leutner, C., Rieber-Brambs, A., Nordhoff, D., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.23.0839 · Cited by 501 · cited 1×
“7% [19], which is comparable to recent prospective studies on MRI screening in women at increased risk such as the Italian Hibcrit trial (91%) [3] and the German EVA trial (93%) [4].”
ResultBenefit of independent double reading in a population-based mammography screening program.
Thurfjell, E. L., Lernevall, K. A., & Taube, A. A. (1994) · Radiology · doi:10.1148/radiology.191.1.8134580 · Cited by 406 · cited 1×
“This is one reason for the implementation of double reading in mammography screening [10, 11].”
BackgroundRitter, F., Boskamp, T., Homeyer, A., Laue, H., Schwier, M., Link, F., & Peitgen, H.-O. (2011) · IEEE Pulse · doi:10.1109/mpul.2011.942929 · Cited by 359
Sardanelli, F., Podo, F., Santoro, F., Manoukian, S., Bergonzi, S., Trecate, G., Vergnaghi, D., Federico, M., Cortesi, L., Corcione, S., et al. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3181f3fcdf · Cited by 337 · cited 1×
“7% [19], which is comparable to recent prospective studies on MRI screening in women at increased risk such as the Italian Hibcrit trial (91%) [3] and the German EVA trial (93%) [4].”
ResultBreast Lesions Detected on MR Imaging: Features and Positive Predictive Value
Liberman, L., Morris, E. A., Lee, M. J.-Y., Kaplan, J. B., LaTrenta, L. R., Menell, J. H., Abramson, A. F., Dashnaw, S. M., Ballon, D. J., & Dershaw, D. D. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.1.1790171 · Cited by 321 · cited 1×
“All lesions in the current MRI, as well as all lesions visible or showing a minimal sign in the prior MRI, were assessed according to the Breast Imaging Reporting and Data (BI-RADS) MR-lexicon and BI-RADS scores were given accordingly [12, 18].”
MethodRiedl, C. C., Luft, N., Bernhart, C., Weber, M., Bernathova, M., Tea, M.-K. M., Rudas, M., Singer, C. F., & Helbich, T. H. (2015) · Journal of Clinical Oncology · doi:10.1200/jco.2014.56.8626 · Cited by 300 · cited 1×
“Breast magnetic resonance imaging (MRI) is recognized as the most sensitive imaging method for the early detection of breast cancer [1].”
MethodBreast cancer missed by mammography
Martin, J., Moskowitz, M., & Milbrath (1979) · American Journal of Roentgenology · doi:10.2214/ajr.132.5.737 · Cited by 246
Using deep learning to segment breast and fibroglandular tissue in MRI volumes
Dalmış, M. U., Litjens, G., Holland, K., Setio, A., Mann, R., Karssemeijer, N., & Gubern‐Mérida, A. (2017) · Medical Physics · doi:10.1002/mp.12079 · Cited by 208 · cited 1×
“Acquisition parameters changed over time, and are reported in detail elsewhere [15].”
BackgroundSelf-citationShah, P. K., Austin, J. H. M., White, C. S., Patel, P., Haramati, L. B., Pearson, G. D. N., Shiau, M. C., & Berkmen, Y. M. (2003) · Radiology · doi:10.1148/radiol.2261011924 · Cited by 198 · cited 1×
“In this case, the lesion is seen but falsely interpreted as benign finding, and might therefore not even be reported, although the most evident cases of interpretation errors obviously mention the lesion as benign in the report [13, 14, 23, 24].”
BackgroundVinokur, A. D., Threatt, B. A., Caplan, R. D., & Zimmerman, B. L. (1989) · Cancer · doi:10.1002/1097-0142(19890115)63:2<394::aid-cncr2820630233>3.0.co;2-5 · Cited by 197 · cited 1×
“Nonetheless, the psychological impact might be substantial and should be taken into account [21].”
BackgroundRigel, D. S., Rivers, J. K., Kopf, A. W., Friedman, R. J., Vinokur, A. F., Heilman, E. R., & Levenstein, M. (1989) · Cancer · doi:10.1002/1097-0142(19890115)63:2<386::aid-cncr2820630231>3.0.co;2-6 · Cited by 168
Automated localization of breast cancer in DCE-MRI
Gubern‐Mérida, A., Martí, R., Melendez, J., Hauth, J., Mann, R. M., Karssemeijer, N., & Platel, B. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.12.001 · Cited by 149 · cited 1×
“The workstation performed motion correction [17], and showed T1-weighted images, subtraction images, and MIPs for all time points.”
MethodSelf-citationKirsh, V. A., Chiarelli, A. M., Edwards, S. A., O’Malley, F. P., Shumak, R. S., Yaffe, M. J., & Boyd, N. F. (2011) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djr138 · Cited by 138 · cited 1×
“These cancers usually are invasive, poorly differentiated and fast growing [22].”
BackgroundDestounis, S. V., DiNitto, P. A., Logan-Young, W. W., Bonaccio, E., Zuley, M. L., & Willison, K. M. (2004) · Radiology · doi:10.1148/radiol.2322030034 · Cited by 124
Tilanus‐Linthorst, M. M. A., Obdeijn, I.-M., Hop, W. C. J., Causer, P. A., Leach, M. O., Warner, E., Pointon, L. J., Hill, K. A., Klijn, J. G. M., Warren, R. M. L., et al. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-0689 · Cited by 119 · cited 1×
“The much higher a priori chance of these women to develop breast cancer compared to other women at increased risk [25], along with the fast growth of cancers in these women [26], leads to lowering Table 2 Visibility of lesions on prior negative MRI scans, stratified by patient and imaging factors”
BackgroundDouble reading of mammography screening films-one radiologist or two?
Anttinen, I., Pamilo, M., Soiva, M., & Roiha, M. (1993) · Clinical Radiology · doi:10.1016/s0009-9260(05)81111-0 · Cited by 118
Breast cancer detection and tumor characteristics in BRCA1 and BRCA2 mutation carriers
Krammer, J., Pinker, K., Robson, M. E., Gönen, M., Bernard‐Davila, B., Morris, E. A., Mangino, D. A., & Jochelson, M. S. (2017) · Breast Cancer Research and Treatment · doi:10.1007/s10549-017-4198-4 · Cited by 113
Self-citationSelective use of sentinel lymph node surgery during prophylactic mastectomy
Boughey, J. C., Khakpour, N., Meric‐Bernstam, F., Ross, M. I., Kuerer, H. M., Singletary, S. E., Babiera, G. V., Arun, B., Hunt, K. K., & Bedrosian, I. (2006) · Cancer · doi:10.1002/cncr.22176 · Cited by 85 · cited 1×
“This is a relative frequent finding in prophylactic mastectomy specimen (approximately 5% in our institution) [20].”
BackgroundVreemann, S., Gubern‐Mérida, A., Schlooz-Vries, M. S., Bult, P., van Gils, C. H., Hoogerbrugge, N., Karssemeijer, N., & Mann, R. M. (2017) · Radiology · doi:10.1148/radiol.2017170458 · Cited by 76
Self-citationMisinterpretation of the chest x ray as a factor in the delayed diagnosis of lung cancer
Turkington, P. M., Kennan, N., & Greenstone, M. A. (2002) · Postgraduate Medical Journal · doi:10.1136/pmj.78.917.158 · Cited by 69
Broeders, M. J. M., Onland‐Moret, N. C., Rijken, H., Hendriks, J. H. C. L., Verbeek, A. L. M., & Holland, R. (2003) · European Journal of Cancer · doi:10.1016/s0959-8049(03)00311-3 · Cited by 67 · cited 2×
“Previous studies [7] have reported that up to 50% of the cancers detected in mammography screening with double reading were already visible at earlier screening examinations and approximately half of these were suspicious.”
ResultBreast Cancers Not Detected at MRI: Review of False-Negative Lesions
Shimauchi, A., Jansen, S. A., Abé, H., Jaskowiak, N. T., Schmidt, R. A., & Newstead, G. M. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.3568 · Cited by 65 · cited 1×
“We assume that very strong BPE might in fact sometimes obscure lesions that would otherwise be detected [27], though larger numbers are required for statistical analyses.”
BackgroundUndiagnosed Breast Cancer at MR Imaging: Analysis of Causes
Pages, E. B., Millet, I., Hoa, D., Doyon, F. C., & Taourel, P. (2012) · Radiology · doi:10.1148/radiol.12111917 · Cited by 65 · cited 3×
“[14] who, in smaller cohorts (15 and 58 patients), reported that 56 and 47% of breast cancers were already visible on prior MRI examinations and retrospectively assessed as BI-RADS-3 or higher.”
BackgroundWeber, R. J. P., van Bommel, R. M. G., Louwman, M. W. J., Nederend, J., Voogd, A. C., Jansen, F. H., Tjan‐Heijnen, V. C. G., & Duijm, L. E. M. (2016) · Breast Cancer Research and Treatment · doi:10.1007/s10549-016-3882-0 · Cited by 61
Yamaguchi, K., Schacht, D. V., Newstead, G. M., Bradbury, A. R., Verp, M. S., Olopade, O. I., & Abé, H. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9707 · Cited by 36 · cited 2×
“A few studies that focused on reasons and features of missed cancers in MRI screening showed that between 47 and 56% of cancers could have been detected at an earlier MRI examination [13, 14].”
BackgroundGubern‐Mérida, A., Vreemann, S., Martí, R., Melendez, J., Lardenoije, S., Mann, R. M., Karssemeijer, N., & Platel, B. (2015) · European Journal of Radiology · doi:10.1016/j.ejrad.2015.11.031 · Cited by 26 · cited 1×
“[29], a CAD system was used for the detection of breast cancer in a subset of 40 of the cancer cases that were used in the current evaluation, mixed with 120 normal scans.”
MethodSelf-citationA True Screening Environment for Review of Interval Breast Cancers: Pilot Study to Reduce Bias
Gordon, P. B., Borugian, M. J., & Burhenne, L. J. W. (2007) · Radiology · doi:10.1148/radiol.2451061798 · Cited by 19 · cited 1×
“While this is common practice in auditing, it has been postulated that this approach is too harsh and leads to more lesions classified as visible than what would have been the case in a blinded setting where cases are mixed with normal scans [28].”
Background
Research works printed but not linked: 1
- American College of Radiology ACR BI-RADS Atlas, 2013 2013 American College of Radiology Reston
Cited by
Mann, R. M., Cho, N., & Moy, L. (2019) · Radiology · doi:10.1148/radiol.2019182947 · Cited by 917
Self-citationContrast‐enhanced MRI for breast cancer screening
Mann, R. M., Kuhl, C. K., & Moy, L. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26654 · Cited by 356
“16 interval cancers, Vreemann et al reported that overall 34% of cancers were actionable on the prior scan.(100) The presence of a BRCA mutation largely reduced the risk on false-negative examinations, which reflects the lower threshold for work-up in these women.”
BackgroundSelf-citationBreast Cancer Screening for Women at Higher-Than-Average Risk: Updated Recommendations From the ACR
Monticciolo, D. L., Newell, M. S., Moy, L., Lee, C. S., & Destounis, S. V. (2023) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2023.04.002 · Cited by 290
Operationalising ethics in artificial intelligence for healthcare: a framework for AI developers
Solanki, P., Grundy, J., & Hussain, W. (2023) · AI and Ethics · doi:10.1007/s43681-022-00195-z · Cited by 157
“For instance, if a patients’ high-risk genetic mutation is known to radiologists, the number of missed breast lesions on MRI scans is known to decrease considerably [38].”
BackgroundArtificial Intelligence Applied to Breast MRI for Improved Diagnosis
Jiang, Y., Edwards, A. V., & Newstead, G. M. (2021) · Radiology · doi:10.1148/radiol.2020200292 · Cited by 137
Metadata
- Authors
- Vreemann, S., Gubern-Merida, A., Lardenoije, S., Bult, P., Karssemeijer, N., Pinker, K., & Mann, R. M.
- Affiliations
- Radboud University Medical Center (NL)
- Memorial Sloan Kettering Cancer Center (US)
- Corresponding author
- Vreemann, S.
- Venue
- Breast Cancer Research and Treatment
- Published
- 2018-01-31
- Volume
- 169
- Issue
- 2
- Pages
- 323-331
- ISSN
- 0167-6806 (ISSN-L)
- 1573-7217
- PMC
- PMC5945731
- OpenAlex
- W2785568893
- Cited by
- 37
- References
- 30
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 3 · 2023: 6 · 2022: 5 · 2021: 2 · 2020: 7 · 2019: 7 · 2018: 3
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- Locations
- Breast Cancer Research and Treatment (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion, other-oa)
- Funders
- Seventh Framework Programme (601040)
- The Netherlands Organisation for Health Research and Development (90514524)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › MRI in cancer diagnosis
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Digital Radiography and Breast Imaging
- Health Sciences › Medicine › Pathology and Forensic Medicine › Breast Lesions and Carcinomas
- Keywords
- breast MRI, BRCA mutations, image quality, background parenchymal enhancement, BI-RADS, interval breast cancer, prophylactic mastectomy, double reading
- MeSH terms
- Adult, Aged, Breast, Breast Neoplasms, Female, Humans, Magnetic Resonance Imaging, Mammography, Mass Screening, Middle Aged, BRCA1 Protein, BRCA2 Protein, Early Detection of Cancer
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.