The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
IVUS-based imaging modalities for tissue characterization: similarities and differences
Open accessAbstract
Gray-scale intravascular ultrasound (IVUS) is the modality that has been established as the golden standard for in vivo imaging of the vessel wall of the coronary arteries. The use of IVUS in clinical practice is an important diagnostic tool used for quantitative assessment of coronary artery disease. This has made IVUS the de-facto invasive imaging method to evaluate new interventional therapies such as new stent designs and for atherosclerosis progression-regression studies. However, the gray-scale representation of the coronary vessel wall and plaque morphology in combination with the limited resolution of the current IVUS catheters makes it difficult, if not impossible, to identify qualitatively (e.g. visually) the plaque morphology similar as that of histopathology, the golden standard to characterize and quantify coronary plaque tissue components. Meanwhile, this limitation has been partially overcome by new innovative IVUS-based post-processing methods such as: virtual histology IVUS (VH-IVUS, Volcano Therapeutics, Rancho Cordova, CA, USA), iMAP-IVUS (Bostoc Scientific, Santa Clara, CA, USA), Integrated Backscatter IVUS (IB-IVUS) and Automated Differential Echogenicity (ADE).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nissen, S. E., Nicholls, S. J., Sipahi, I., Libby, P., Raichlen, J. S., Ballantyne, C. M., Davignon, J., Erbel, R., Fruchart, J. C., Tardif, J.-C., et al. (2006) · JAMA · doi:10.1001/jama.295.13.jpc60002 · Cited by 2,047
Nissen, S. E., Tsunoda, T., Tuzcu, E. M., Schoenhagen, P., Cooper, C. J., Yasin, M., Eaton, G. M., Lauer, M. A., Sheldon, W. S., Grines, C. L., et al. (2003) · JAMA · doi:10.1001/jama.290.17.2292 · Cited by 1,707
Cited by
Calcium Burden Assessment and Impact on Drug-Eluting Balloons in Peripheral Arterial Disease
Fanelli, F., Cannavale, A., Gazzetti, M., Lucatelli, P., Wlderk, A., Cirelli, C., d’Adamo, A., & Salvatori, F. M. (2014) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-014-0904-3 · Cited by 408
Coronary Atherosclerotic Vulnerable Plaque: Current Perspectives
Stefanadis, C., Antoniou, C., Tsiachris, D., & Pietri, P. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.005543 · Cited by 273
Athanasiou, L., Rigas, G., Sakellarios, A. I., Exarchos, T. P., Siogkas, P. K., Bourantas, C. V., Garcia-Garcia, H. M., Lemos, P. A., Falcao, B. A., Michalis, L. K., et al. (2016) · BMC Medical Imaging · doi:10.1186/s12880-016-0111-6 · Cited by 48
“79); fact that should be attributed to the fact that IVUS cannot portray the entire CP (acoustic shadow) [29, 30] and to that in CTA large CP plaques appear enlarged (blooming effect) [31].”
Background
Metadata
- Authors
- Garcìa-Garcìa, H. M., Gogas, B. D., Serruys, P. W., & Bruining, N.
- Venue
- The International Journal of Cardiovascular Imaging
- Published
- 2011-02
- Volume
- 27
- Issue
- 2
- Pages
- 215-224
- ISSN
- 0167-9899 (ISSN-L)
- 1569-5794
- 1573-0743
- OpenAlex
- W2145140351
- Cited by
- 196
- References
- 2
- FWCI
- 11.45
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: IVUS-based imaging modalities for tissue characterization: similarities and differences. https://app.cochat.ai/papers/10.1007/s10554-010-9789-7
- The paper
- Garcìa-Garcìa, H. M., Gogas, B. D., Serruys, P. W., & Bruining, N. (2011). IVUS-based imaging modalities for tissue characterization: similarities and differences. The International Journal of Cardiovascular Imaging. https://doi.org/10.1007/s10554-010-9789-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.