Deploying human activity recognition in embedded RISC-V processors
Open accessPublished version of a preprint
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Deep Convolutional and LSTM Recurrent Neural Networks for Multimodal Wearable Activity Recognition
Ordóñez, F., & Roggen, D. (2016) · Sensors · doi:10.3390/s16010115 · Cited by 2,761 · cited 2× · see citing works
“Ordóñez and Roggen [24] proposed a new DNN framework designed for activity recognition using wearable sensors.”
UniMiB SHAR: A Dataset for Human Activity Recognition Using Acceleration Data from Smartphones
Micucci, D., Mobilio, M., & Napoletano, P. (2017) · doi:10.20944/preprints201706.0033.v1 · Cited by 596 · see citing works
UniMiB SHAR: A Dataset for Human Activity Recognition Using Acceleration Data from Smartphones
Micucci, D., Mobilio, M., & Napoletano, P. (2017) · Applied Sciences · doi:10.3390/app7101101 · Cited by 596 · see citing works
Learning to Quantize Deep Networks by Optimizing Quantization Intervals With Task Loss
Jung, S., Son, C., Lee, S., Son, J., Han, J.-J., Kwak, Y., Hwang, S. J., & Choi, C. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.00448 · Cited by 385 · see citing works
Protecting Sensory Data against Sensitive Inferences
Malekzadeh, M., Clegg, R. G., Cavallaro, A., & Haddadi, H. (2018) · Proceedings of the 1st Workshop on Privacy by Design in Distributed Systems · doi:10.1145/3195258.3195260 · Cited by 154 · see citing works
Zebin, T., Sperrin, M., Peek, N., & Casson, A. J. (2018) · 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513115 · Cited by 107 · see citing works
Flagged first, then by citations
- Authors
- Nunes, W. A., Reusch, R. S., Luza, L., Bernardon, E., Dal Zotto, A. E., Juracy, L. R., & Moraes, F. G.
- Affiliations
- Pontifícia Universidade Católica do Rio Grande do Sul (BR)
- Corresponding author
- Moraes, Fernando Gehm
- ORCID
- Venue
- Design Automation for Embedded Systems
- Published
- 2024-11-16
- Volume
- 28
- Issue
- 3-4
- Pages
- 187-217
- ISSN
- 0929-5585 (ISSN-L)
- 1572-8080
- OpenAlex
- W4404432711
- Cited by
- 0
- References
- 6
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Licence
- Locations
- Design Automation for Embedded Systems (publishedVersion, public-domain)
- Research Square (acceptedVersion, cc-by)
- Funders
- Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul (21/2551-0002047-4 and 23/2551-0002200-1)
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (Finance Code 001)
- Conselho Nacional de Desenvolvimento Científico e Tecnológico (309605/2020-2 and 407829/2022-9)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Neural Network Applications
- Physical Sciences › Computer Science › Hardware and Architecture › Embedded Systems Design Techniques
- Keywords
- human activity recognition, RISC-V processor, embedded systems, convolutional neural networks, model quantization, 1D convolutional neural network, wearable devices, low-power deployment, memory optimization, health monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review