ISCEV Standard for Clinical Electro-oculography (EOG) 2006
Open accessThe DOI matches its Crossref record.
Abstract
The Clinical Electro-oculogram (EOG) is an electrophysiological test of function of the outer retina and retinal pigment epithelium (RPE) in which the change in the electrical potential between the cornea and the ocular fundus is recorded during successive periods of dark and light adaptation. This document sets out a Standard Method for performance of the test, and also gives detailed guidance on technical and practical issues, and on reporting test results. The main object of the Standard is to promote consistent quality of testing and reporting within and between centres. This 2006 Standard, from the International Society for Clinical Electrophysiology of Vision (ISCEV: www.iscev.org ), is a revision of the previous Standard published in 1993, and reviewed and re-issued in 1998.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ISCEV Standard for full-field clinical electroretinography (2008 update)
Marmor, M. F., Fulton, A. B., Holder, G. E., Miyake, Y., Brigell, M., Bach, M., & (for the International Society for Clinical Electrophysiology of Vision) (2009) · Documenta Ophthalmologica · doi:10.1007/s10633-008-9155-4 · Cited by 1,003
Self-citationISCEV standard for clinical visual evoked potentials (2009 update)
Odom, J. V., Bach, M., Brigell, M., Holder, G. E., McCulloch, D. L., Tormene, A. P., & Vaegan (2010) · Documenta Ophthalmologica · doi:10.1007/s10633-009-9195-4 · Cited by 829
Self-citationEye Movement Analysis for Activity Recognition Using Electrooculography
Bulling, A., Ward, J. A., Gellersen, H., & Tröster, G. (2011) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2010.86 · Cited by 718
Printed subthreshold organic transistors operating at high gain and ultralow power
Jiang, C., Choi, H. W., Cheng, X., Ma, H., Hasko, D., & Nathan, A. (2019) · Science · doi:10.1126/science.aav7057 · Cited by 308
Klaib, A. F., Alsrehin, N. O., Melhem, W. Y., Bashtawi, H. O., & Magableh, A. A. (2021) · Expert Systems with Applications · doi:10.1016/j.eswa.2020.114037 · Cited by 263
Bestrophin 1 and retinal disease
Johnson, A. A., Guziewicz, K. E., Lee, C. J., Kalathur, R. C., Pulido, J. S., Marmorstein, L. Y., & Marmorstein, A. D. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.01.006 · Cited by 237
“Per International Society for Clinical Electrophysiology of Vision standards (Brown et al., 2006), a normal LP/DT ratio is typically 2.0 or greater and, with Best disease, the LP/DT ratio falls below 1.55.”
InfluentialWearable eye tracking for mental health monitoring
Vidal, M., Turner, J., Bulling, A., & Gellersen, H. (2012) · Computer Communications · doi:10.1016/j.comcom.2011.11.002 · Cited by 192
Treatment of a retinal dystrophy, fundus albipunctatus, with oral 9-cis- -carotene
Rotenstreich, Y., Harats, D., Shaish, A., Pras, E., & Belkin, M. (2010) · British Journal of Ophthalmology · doi:10.1136/bjo.2009.167049 · Cited by 51
“Before and immediately after treatment, each patient underwent a full ophthalmological examination, Humphrey visual-field testing (central 24–2 threshold test) and bilateral electroretinographic (ERG) recording (UTAS-E3000; LKC Technologies, Gaithersburg, Maryland) of full-field responses.”
Method
Metadata
- Authors
- Brown, M., Marmor, M., Vaegan, Zrenner, E., Brigell, M., & Bach, M.
- Venue
- Documenta Ophthalmologica
- Published
- 2006-11
- Volume
- 113
- Issue
- 3
- Pages
- 205-212
- ISSN
- 0012-4486 (ISSN-L)
- 1573-2622
- OpenAlex
- W2046396053
- Cited by
- 174
- References
- 0
- FWCI
- 3.44
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.