CoChat

Flicker cone function in normal and day blind sheep: a large animal model for human achromatopsia caused by CNGA3 mutation

Open access
Ezra-Elia, Raaya, Banin, Eyal, Honig, Hen, Rosov, Alexander, Obolensky, Alexey, Averbukh, Edward, Hauswirth, William W., Gootwine, Elisha, Ofri, Ron · 2014 · Documenta Ophthalmologica
Cited by 21

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PurposeRecently we reported on day blindness in sheep caused by a mutation in the CNGA3 gene, thus making affected sheep a naturally occurring large animal model for therapeutic intervention in CNGA3 achromatopsia patients. The purpose of this study was to characterize flicker cone function in normal and day blind sheep, with the aim of generating a normative data base for ongoing gene therapy studies.MethodsElectoretinographic (ERG) cone responses were evoked with full-field conditions in 10 normal, 6 heterozygous carriers and 36 day blind sheep. Following light adaptation (10 min, 30 cd/m2), responses were recorded at four increasing light intensities (1, 2.5, 5 and 10 cd s/m2). At each of these intensities, a single photopic flash response followed by 8 cone flicker responses (10–80 Hz) was recorded. Results were used to generate a normative data base for the three groups. Differences between day blind and normal control animals were tested in two age-matched groups (n = 10 per group).ResultsThe normal sheep cone ERG wave is bipartite in nature, with critical flicker fusion frequency (CFF) >80 Hz. In all four flash intensities, the single photopic flash a-wave and b-wave amplitudes were significantly lower (p < 0.005), and implicit times significantly delayed (p < 0.0001), in day blind animals. In all four flash intensities, CFF values were significantly lower (p < 0.0001) in day blind sheep.ConclusionsCone function is severely depressed in day blind sheep. Our results will provide a normative data base for ongoing gene therapy studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s10633-014-9458-6

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 21

Metadata

Authors
Ezra-Elia, R., Banin, E., Honig, H., Rosov, A., Obolensky, A., Averbukh, E., Hauswirth, W. W., Gootwine, E., & Ofri, R.
Venue
Documenta Ophthalmologica
Published
2014-09-10
Volume
129
Issue
3
Pages
141-150
ISSN
  • 0012-4486 (ISSN-L)
  • 1573-2622
OpenAlex
W2031703739
Cited by
21
References
2
FWCI
1.10
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.