The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
ISCEV guide to visual electrodiagnostic procedures
Open accessAbstract
Clinical electrophysiological testing of the visual system incorporates a range of noninvasive tests and provides an objective indication of function relating to different locations and cell types within the visual system. This document developed by the International Society for Clinical Electrophysiology of Vision provides an introduction to standard visual electrodiagnostic procedures in widespread use including the full-field electroretinogram (ERG), the pattern electroretinogram (pattern ERG or PERG), the multifocal electroretinogram (multifocal ERG or mfERG), the electrooculogram (EOG) and the cortical-derived visual evoked potential (VEP). The guideline outlines the basic principles of testing. Common clinical presentations and symptoms are described with illustrative examples and suggested investigation strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ISCEV Standard for full-field clinical electroretinography (2015 update)
McCulloch, D. L., Marmor, M. F., Brigell, M. G., Hamilton, R., Holder, G. E., Tzekov, R., & Bach, M. (2015) · Documenta Ophthalmologica · doi:10.1007/s10633-014-9473-7 · Cited by 1,313
Self-citationISCEV standard for clinical visual evoked potentials (2009 update)
Odom, J. V., Bach, M., Brigell, M., Holder, G. E., McCulloch, D. L., Tormene, A. P., & Vaegan (2010) · Documenta Ophthalmologica · doi:10.1007/s10633-009-9195-4 · Cited by 829
Self-citationISCEV standard for clinical visual evoked potentials: (2016 update)
International Society for Clinical Electrophysiology of Vision, Odom, J. V., Bach, M., Brigell, M., Holder, G. E., McCulloch, D. L., Mizota, A., & Tormene, A. P. (2016) · Documenta Ophthalmologica · doi:10.1007/s10633-016-9553-y · Cited by 699
Self-citationISCEV standard for clinical pattern electroretinography (PERG): 2012 update
Bach, M., Brigell, M. G., Hawlina, M., Holder, G. E., Johnson, M. A., McCulloch, D. L., Meigen, T., & Viswanathan, S. (2013) · Documenta Ophthalmologica · doi:10.1007/s10633-012-9353-y · Cited by 634
Self-citationISCEV standard for clinical multifocal electroretinography (mfERG) (2011 edition)
For the International Society For Clinical Electrophysiology of Vision, Hood, D. C., Bach, M., Brigell, M., Keating, D., Kondo, M., Lyons, J. S., Marmor, M. F., McCulloch, D. L., & Palmowski-Wolfe, A. M. (2012) · Documenta Ophthalmologica · doi:10.1007/s10633-011-9296-8 · Cited by 627
Pattern Electroretinography (PERG) and an Integrated Approach to Visual Pathway Diagnosis
Holder, G. E. (2001) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(00)00030-6 · Cited by 368
Self-citation
Cited by
Michaelides, M., Hirji, N., Wong, S. C., Besirli, C. G., Zaman, S., Kumaran, N., Georgiadis, A., Smith, A. J., Ripamonti, C., Gottlob, I., et al. (2023) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2023.05.009 · Cited by 54
Self-citationSyndromic retinitis pigmentosa.
Karuntu, J. S., Almushattat, H., Nguyen, X.-T.-A., Plomp, A. S., Wanders, R. J. A., Hoyng, C. B., van Schooneveld, M. J., Schalij-Delfos, N. E., Brands, M. M., Leroy, B. P., et al. (2025) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2024.101324 · Cited by 39
Metadata
- Authors
- Robson, A. G., Nilsson, J., Li, S., Jalali, S., Fulton, A. B., Tormene, A. P., Holder, G. E., & Brodie, S. E.
- Venue
- Documenta Ophthalmologica
- Published
- 2018-02
- Volume
- 136
- Issue
- 1
- Pages
- 1-26
- ISSN
- 0012-4486 (ISSN-L)
- 1573-2622
- OpenAlex
- W2793243054
- Cited by
- 366
- References
- 6
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ISCEV guide to visual electrodiagnostic procedures. https://app.cochat.ai/papers/10.1007/s10633-017-9621-y
- The paper
- Robson, A. G., Nilsson, J., Li, S., Jalali, S., Fulton, A. B., Tormene, A. P., Holder, G. E., & Brodie, S. E. (2018). ISCEV guide to visual electrodiagnostic procedures. Documenta Ophthalmologica. https://doi.org/10.1007/s10633-017-9621-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.