CoChat

Apnea–hypopnea index as a predictor of atrial fibrillation recurrence following initial pulmonary vein isolation: usefulness of type-3 portable monitor for sleep-disordered breathing

The DOI matches its Crossref record; 22 of the 23 references it cites were found in a registry or an index.

Abstract

Purpose The relationship between atrial fibrillation (AF) recurrence after pulmonary vein isolation (PVI) and sleep-disordered breathing (SDB) evaluated using type-3 portable monitoring (PM) is still unknown. We investigated high-risk patients with AF recurrence after initial PVI using the apnea-hypopnea index (AHI) measured by type-3 PM. Methods One hundred twenty-four (85 males; age 62 ± 10 years) AF patients undergoing initial PVI were enrolled: 83, paroxysmal AF; 41, persistent AF. At baseline, all patients were subjected to in-hospital unattended overnight polygraphy using type-3 PM for SDB. Results During 13 ± 7 months following initial PVI, 47 patients (38 %) experienced AF recurrence. AHI and left atrial volume index (LAVI) were significantly greater in patients with than in those without AF recurrence (AHI P = 0.011; LAVI P Conclusions AHI measured using type-3 PM is a useful predictor of outcome following initial PVI in patients with paroxysmal AF.

Overview

Integrity signals

Registry

Crossref · 10.1007/s10840-016-0148-z

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 22 references

Cited by

See all 26

Metadata

Authors
Kawakami, H., Nagai, T., Fujii, A., Uetani, T., Nishimura, K., Inoue, K., Suzuki, J., Oka, Y., Okura, T., Higaki, J., Ogimoto, A., & Ikeda, S.
Affiliations
  • Ehime University (JP)
  • Ehime University Hospital (JP)
Corresponding author
Nagai, Takayuki
Venue
Journal of Interventional Cardiac Electrophysiology
Published
2016-06-08
Volume
47
Issue
2
Pages
237-244
ISSN
  • 1383-875X (ISSN-L)
  • 1572-8595
OpenAlex
W2417192379
Cited by
23
References
23
Citations by year
2026: 1 · 2025: 1 · 2024: 7 · 2023: 1 · 2022: 3 · 2021: 3 · 2020: 3 · 2019: 2 · 2018: 1 · 2017: 1
FWCI
1.10
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Interventional Cardiac Electrophysiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
Keywords
atrial fibrillation recurrence, pulmonary vein isolation, apnea-hypopnea index, sleep-disordered breathing, left atrial volume index, paroxysmal atrial fibrillation, persistent atrial fibrillation, risk prediction, catheter ablation
MeSH terms
Atrial Fibrillation, Female, Heart Conduction System, Humans, Male, Middle Aged, Pulmonary Veins, Recurrence, Retrospective Studies, Sensitivity and Specificity, Severity of Illness Index, Sleep Apnea Syndromes, Reproducibility of Results, Treatment Outcome, Outcome Assessment, Health Care, Polysomnography, Disease-Free Survival

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Apnea–hypopnea index as a predictor of atrial fibrillation recurrence following initial pulmonary vein isolation: usefulness of type-3 portable monitor for sleep-disordered breathing. https://app.cochat.ai/papers/10.1007/s10840-016-0148-z
The paper
Kawakami, H., Nagai, T., Fujii, A., Uetani, T., Nishimura, K., Inoue, K., Suzuki, J., Oka, Y., Okura, T., Higaki, J., Ogimoto, A., & Ikeda, S. (2016). Apnea–hypopnea index as a predictor of atrial fibrillation recurrence following initial pulmonary vein isolation: usefulness of type-3 portable monitor for sleep-disordered breathing. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-016-0148-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.